SearcharxivSearch

arXiv subjects

Wenying Li

Publications and source records attributed to Wenying Li.

2 recordsLinked to original sources

Expanding mmWave Datasets for Human Pose Estimation with Unlabeled Data and LiDAR Datasets

Current millimeter-wave (mmWave) datasets for human pose estimation (HPE) are scarce and lack diversity in both point cloud (PC) attributes and human poses, hindering the generalization ability of their trained models. On the other hand, unlabeled mmWave HPE data and diverse LiDAR HPE datasets are readily available. We propose EMDUL, a novel approach to expand the volume and diversity of an existing mmWave dataset using unlabeled mmWave data and LiDAR datasets. EMDUL consists of two independent modules, namely a pseudo-label estimator to annotate unlabeled mmWave data, and a closed-form converter that translates an annotated LiDAR PC to its mmWave counterpart. Expanding the original dataset with both LiDAR-converted and pseudo-labeled mmWave PCs significantly boosts the performance and generalization ability of all the examined HPE models, reducing 15.1% and 18.9% error for in-domain and out-of-domain settings, respectively. Code is available at https://github.com/Shimmer93/EMDUL.

cs.CV

Dynamic Modeling and Control of Multi-Stack Alkaline Water Electrolysis Systems with Shared Gas Separators and Lye Circulation:Industrial Data-Based Validation and Simulation

An emerging approach for large-scale renewable hydrogen production is integrating multiple alkaline water electrolysis (AWE) stacks into one balance-of-plant (BoP) system, sharing gas-lye separation and lye circulation components. While this configuration, termed $N$-in-1, reduces cost and complexity, its dynamic performance under fluctuating power remains unclear compared with conventional 1-in-1 systems. This paper develops a state-space model of the multi-stack AWE system, capturing lye circulation, temperature, and hydrogen-to-oxygen (HTO) dynamics, calibrated via experiments on a 4,000 Nm$^3$/h-rated 4-in-1 system. A mixed-integer quadratic programming (MIQP)-based predictive controller is then designed to coordinate inter-stack current distribution, lye flow, and cooling for load tracking and operational stability. Simulations on the experimentally validated model show that a $4$-in-1 system achieves similar performance compared to four parallel 1-in-1 systems under continuous operation. Differences in load-tracking, temperature stabilization errors, and specific energy consumption remain below 0.015 MW, 0.346 K, and 0.001 kWh/Nm$^3$ under wind power supply when all stacks remain online.

math.OC