SearcharxivSearch

arXiv subjects

Xavier Tonon

Publications and source records attributed to Xavier Tonon.

3 recordsLinked to original sources

High-Density Ultracold Neutron Source for Low-Energy Particle Physics Experiments

SuperSUN, a new superthermal source of ultracold neutrons (UCN) at the Institut Laue-Langevin, exploits inelastic scattering of neutrons in isotopically pure superfluid $^4$He at temperatures below $0.6\,$K. For the first time, continuous operation with an intense broad-spectrum cold neutron beam is demonstrated over 60 days. We observe continuous UCN extraction rates of $21000\,$s$^{-1}$, and storage in the source with saturated density $273\,$cm$^{-3}$. The low-energy $\textit{in-situ}$ UCN spectrum is alterable via accumulation and holding delays, opening new possibilities in fundamental and applied physics.

physics.ins-det

The PanEDM Neutron Electric Dipole Moment Experiment at the ILL

The neutron's permanent electric dipole moment $d_n$ is constrained to below $3\times10^{-26} e~\text{cm}$ (90% C.L.) [ arXiv:hep-ex/0602020, arXiv:1509.04411 ], by experiments using ultracold neutrons (UCN). We plan to improve this limit by an order of magnitude or more with PanEDM, the first experiment exploiting the ILL's new UCN source SuperSUN. SuperSUN is expected to provide a high density of UCN with energies below 80 neV, implying extended statistical reach with respect to existing sources, for experiments that rely on long storage or spin-precession times. Systematic errors in PanEDM are strongly suppressed by passive magnetic shielding, with magnetic field and gradient drifts at the single fT level. A holding-field homogeneity on the order of $10^{-4}$ is achieved in low residual fields, via a high static damping factor and built-in coil system. No comagnetometer is needed for the first order-of-magnitude improvement in $d_n$, thanks to high magnetic stability and an assortment of sensors outside the UCN storage volumes. PanEDM will be commissioned and upgraded in parallel with SuperSUN, to take full advantage of the source's output in each phase. Commissioning is ongoing in 2019, and a new limit in the mid $10^{-27} e~\text{cm}$ range should be possible with two full reactor cycles of data in the commissioned apparatus.

physics.ins-det

40-tesla pulsed-field cryomagnet for single crystal neutron diffraction

We present the first long-duration and high duty cycle 40-tesla pulsed-field cryomagnet addressed to single crystal neutron diffraction experiments at temperatures down to 2 K. The magnet produces a horizontal field in a bi-conical geometry, $\pm$15 and $\pm$30° upstream and downstream of the sample, respectively. Using a 1.15MJ mobile generator, magnetic field pulses of 100 ms length are generated in the magnet, with a rise time of 23 ms and a repetition rate of 6-7 pulses per hour at 40 T. The setup was validated for neutron diffraction on the CEA-CRG three-axis spectrometer IN22 at the ILL.

physics.ins-det