Searcharxiv⌕ Search

arXiv subjects

Xiaofeng Zhang

Publications and source records attributed to Xiaofeng Zhang.

93 records · Page 6Linked to original sources

Towards well-specified semi-supervised model-based classifiers via structural adaptation

Semi-supervised learning plays an important role in large-scale machine learning. Properly using additional unlabeled data (largely available nowadays) often can improve the machine learning accuracy. However, if the machine learning model is misspecified for the underlying true data distribution, the model performance could be seriously jeopardized. This issue is known as model misspecification. To address this issue, we focus on generative models and propose a criterion to detect the onset of model misspecification by measuring the performance difference between models obtained using supervised and semi-supervised learning. Then, we propose to automatically modify the generative models during model training to achieve an unbiased generative model. Rigorous experiments were carried out to evaluate the proposed method using two image classification data sets PASCAL VOC'07 and MIR Flickr. Our proposed method has been demonstrated to outperform a number of state-of-the-art semi-supervised learning approaches for the classification task.

cs.LG↗

A crosstalk and non-uniformity correction method for the Compact Space-borne Compton Polarimeter POLAR

In spite of extensive observations and numerous theoretical studies in the past decades several key questions related with Gamma-Ray Bursts (GRB) emission mechanisms are still to be answered. Precise detection of the GRB polarization carried out by dedicated instruments can provide new data and be an ultimate tool to unveil their real nature. A novel space-borne Compton polarimeter POLAR onboard the Chinese space station TG2 is designed to measure linear polarization of gamma-rays arriving from GRB prompt emissions. POLAR uses plastics scintillator bars (PS) as gamma-ray detectors and multi-anode photomultipliers (MAPMTs) for readout of the scintillation light. Inherent properties of such detection systems are crosstalk and non-uniformity. The crosstalk smears recorded energy over multiple channels making both non-uniformity corrections and energy calibration more difficult. Rigorous extraction of polarization observable requires to take such effects properly into account. We studied influence of the crosstalk on energy depositions during laboratory measurements with X-ray beams. A relation between genuine and recorded energy was deduced using an introduced model of data analysis. It postulates that both the crosstalk and non-uniformities can be described with a single matrix obtained in calibrations with mono-energetic X- and gamma-rays. Necessary corrections are introduced using matrix based equations allowing for proper evaluation of the measured GRB spectra. Validity of the method was established during dedicated experimental tests. The same approach can be also applied in space utilizing POLAR internal calibration sources. The introduced model is general and with some adjustments well suitable for data analysis from other MAPMT-based instruments.

physics.ins-det↗

Surface atomic diffusion processes observed at milliseconds time resolution using environmental TEM

Significant progress has been made in spatial resolution using environmental transmission electron microscopes (ETEM), which now enables atomic resolution visualization of structural transformation under variable temperature and gas environments close to materials real operational conditions. Structural transformations are observed by recording images or diffraction patterns at various time intervals using a video camera or by taking snap shots using electron pulses. While time resolution at 15 ns has been reported using pulsed electron beams, the time interval that can be recorded by this technique is currently very limited. For longer recording, however, time resolution inside ETEM has been limited by electron cameras to ~1/30 seconds for a long time. Using the recently developed direct electron detection technology, we have significantly improved the time resolution of ETEM to 2.5 ms (milliseconds) for full frame or 0.625 ms for 0.25 frames.

cond-mat.mtrl-sci↗