SearcharxivSearch

arXiv subjects

Xuefeng Lu

Publications and source records attributed to Xuefeng Lu.

16 recordsLinked to original sources

Development and characterization of a millimeter-wave cold load prototype

Superconducting transition-edge sensors (TESs) are crucial detectors for cosmic microwave background (CMB) observations and require stable and tunable millimeter-wave cold loads for optical-efficiency calibration. This work presents the design, fabrication, and preliminary characterization of a 4-20 K millimeter-wave cold load prototype intended for integration into the 1 K stage of a dilution refrigerator and subsequent 40/90 GHz CMB TES calibration experiments. Two absorber prototypes based on commercially available CR-110 and a Stycast 2850FT composite were fabricated and studied. Simulation results show that both absorber structures exhibit small predicted steady-state temperature gradients and low normal-incidence reflectance in the target frequency bands. Room-temperature S11 measurements were used only to screen low-reflectance cold load prototype, and the measured results generally agree with the electromagnetic simulations. The measured S11 of the Stycast 2850FT composite is comparable to that of the commercial absorber TK RAM. Additionally, to explore a more readily obtainable alternative absorber material, TIE280-25AB was preliminarily evaluated by measuring its electromagnetic parameters. Based on the measured parameters, the simulated S11 of the TIE280-25AB pyramidal absorber structure is comparable to those of CR-110 and the Stycast 2850FT composite over 33-110 GHz. These results identify CR-110 and the Stycast 2850FT composite as promising absorbers for subsequent cryogenic evaluation. The absolute low-temperature emissivity, effective radiation temperature, and TES calibration performance remain to be established through future cryogenic radiometric and TES based optical-power measurements.

astro-ph.IM

Beyond One-Thousandth Energy Resolution with an AlMn TES Detector

The superconducting Transition-Edge Sensor (TES) is a critical technology for next-generation X-ray spectrometers, known for its exceptional energy resolution. In the last decade, TESs based on AlMn alloy films have been extensively used in several cosmic microwave background (CMB) experiments. The advantages of simple fabrication process and easily tunable critical temperature make them an alternative to bilayer TESs. However, they have rarely been applied to X-ray detection until now. We developed an annular AlMn TES for X-ray detection and tested it in a dilution refrigerator with a Superconducting Quantum Interference Device (SQUID) amplifier, achieving an Full Width at Half Maximum (FWHM) of 12.1 +- 0.3 eV at 17.48 keV. To the best of our knowledge, this is the first demonstration of an AlMn TES achieving an energy resolution below 0.1%, highlighting its potential for high-resolution X-ray detection.

astro-ph.IM

Fabrication and characterization of AlMn alloy superconducting films for 0vbb experiments

Neutrinoless double-beta decay (0vbb) experiments constitute a pivotal probe for elucidating the characteristics of neutrinos and further discovering new physics. Compared to the neutron transmutation doped germanium thermistors (NTD-Ge) used in 0vbb experiments such as CUORE, transition edge sensors (TES) theoretically have a relatively faster response time and higher energy resolution. These make TES detectors good choice for next generation 0vbb experiments. In this paper, AlMn alloy superconducting films, the main components of TES, were prepared and studied. The relationship between critical temperature (Tc) and annealing temperature was established, and the impact of magnetic field on Tc was tested. The experimental results demonstrate that the Tc of AlMn film can be tuned in the required range of 10 - 20 mK by using the above methods, which is a key step for the application of AlMn TES in 0vbb experiment. In the test range, the Tc of AlMn film is sensitive to out-of-plane magnetic field but not to the in-plane magnetic field. Furthermore, we find that a higher annealing temperature results in a more uniform distribution of Mn ions in depth, which opens a new avenue for elucidating the underlying mechanism for tuning Tc.

hep-ex

Fabrication and Characterization of X-ray TES Detectors Based on Annular AlMn Alloy Films

AlMn alloy flms are widely fabricated into superconducting transition edge sensors (TESs) for the detection of cosmic microwave background radiation. However, the application in X-ray or gamma-ray detection based on AlMn TES is rarely reported. In this study, X-ray TES detectors based on unique annular AlMn flms are devel-oped. The fabrication processes of TES detectors are introduced in detail. The char-acteristics of three TES samples are evaluated in a dilution refrigerator. The results demonstrate that the I-V characteristics of the three annular TES detectors are highly consistent. The TES detector with the smallest absorber achieved the best energy resolution of 11.0 eV @ 5.9 keV, which is inferior to the theoretical value. The dis-crepancy is mainly attributed to the larger readout electronics noise than expected.

physics.ins-det

Development of 6-inch 80-170 GHz broadband silicon plated horn antenna arrays for primordial gravitational wave search

Searching for primordial gravitational wave in cosmic microwave background (CMB) polarization signal is one of the key topics in modern cosmology. Cutting-edge CMB telescopes requires thousands of pixels to maximize mapping speed. Using modular design, the telescope focal plane is simplified as several detector modules. Each module has hundreds of pixels including antenna arrays, detector arrays, and readout arrays. The antenna arrays, as the beam defining component, determine the overall optical response of the detector module. In this article, we present the developments of 6-inch broadband antenna arrays from 80GHz to 170GHz for the future IHEP focal plane module. The arrays are fabricated from 42 6-inch silicon wafers including 456 antennas, 7% more pixels than usual design. The overall in-band cross polarization is smaller than -20 dB and the in-band beam asymmetry is smaller than 10%, fulfilling the requirements for primordial gravitational wave search.

astro-ph.IM

The Sliding Flux Ramp Demodulation Algorithm with High Sampling Rate in Microwave SQUID Multiplexer

Microwave SQUID Multiplexing (uMUX) is a widely used technique in the low temperature detectors community as it offers high capacity of reading out large scale Transition-Edge Sensor (TES) arrays. In this paper, we propose a Sliding Flux Ramp Demodulation (SFRD) algorithm for uMUX readout system. It can achieve a sampling rate in the order of MHz while maintaining a multiplexing ratio about one thousand. Advancing of this large array readout technique makes it possible to observe scientiffc objects with improved time resolution and event count rate. This will be highly helpful for TES calorimeters in X-ray applications, such as X-ray astrophysics missions.

hep-ex

ILETIA: An AI-enhanced method for individualized trigger-oocyte pickup interval estimation of progestin-primed ovarian stimulation protocol

In vitro fertilization-embryo transfer (IVF-ET) stands as one of the most prevalent treatments for infertility. During an IVF-ET cycle, the time interval between trigger shot and oocyte pickup (OPU) is a pivotal period for follicular maturation, which determines mature oocytes yields and impacts the success of subsequent procedures. However, accurately predicting this interval is severely hindered by the variability of clinicians'experience that often leads to suboptimal oocyte retrieval rate. To address this challenge, we propose ILETIA, the first machine learning-based method that could predict the optimal trigger-OPU interval for patients receiving progestin-primed ovarian stimulation (PPOS) protocol. Specifically, ILETIA leverages a Transformer to learn representations from clinical tabular data, and then employs gradient-boosted trees for interval prediction. For model training and evaluating, we compiled a dataset PPOS-DS of nearly ten thousand patients receiving PPOS protocol, the largest such dataset to our knowledge. Experimental results demonstrate that our method achieves strong performance (AUROC = 0.889), outperforming both clinicians and other widely used computational models. Moreover, ILETIA also supports premature ovulation risk prediction in a specific OPU time (AUROC = 0.838). Collectively, by enabling more precise and individualized decisions, ILETIA has the potential to improve clinical outcomes and lay the foundation for future IVF-ET research.

q-bio.QM

Insight-HXMT on-orbit thermal control status and thermal deformation impact analysis

Purpose: The Hard X-ray Modulation Telescope is China's first X-ray astronomy satellite launched on June 15th, 2017, dubbed Insight-HXMT. Active and passive thermal control measures are employed to keep devices at suitable temperatures. In this paper, we analyzed the on-orbit thermal monitoring data of the first 5 years and investigated the effect of thermal deformation on the point spread function (PSF) of the telescopes. Methods: We examined the data of the on-orbit temperatures measured using 157 thermistors placed on the collimators, detectors and their support structures and compared the results with the thermal control requirements. The thermal deformation was evaluated by the relative orientation of the two star sensors installed on the main support structure. its effect was estimated with evolution of the PSF obtained with calibration scanning observations of the Crab nebula. Conclusion: The on-orbit temperatures met the thermal control requirements thus far, and the effect of thermal deformation on the PSF was negligible after the on-orbit pointing calibration.

astro-ph.IM

Burst phase distribution of SGR J1935+2154 based on Insight-HXMT

On April 27, 2020, the soft gamma ray repeater SGR J1935+2154 entered its intense outburst episode again. Insight-HXMT carried out about one month observation of the source. A total number of 75 bursts were detected during this activity episode by Insight-HXMT, and persistent emission data were also accumulated. We report on the spin period search result and the phase distribution of burst start times and burst photon arrival times of the Insight-HXMT high energy detectors and Fermi Gamma-ray Burst Monitor (GBM). We find that the distribution of burst start times is uniform within its spin phase for both Insight-HXMT and Fermi-GBM observations, whereas the phase distribution of burst photons is related to the type of a burst's energy spectrum. The bursts with the same spectrum have different distribution characteristics in the initial and decay episodes for the activity of magnetar SGR J1935+2154.

astro-ph.HE

An Insight-HXMT view of the mHz quasi-regular modulation phenomenon in the black hole X-ray binary 4U 1630-47

Here we report the spectral-timing results of the black hole X-ray binary 4U 1630-47 during its 2021 outburst using observations from the Hard X-ray Modulation Telescope. Type-C quasi-periodic oscillations (QPOs) in 1.6--4.2 Hz and quasi-regular modulation (QRM) near 60 mHz are detected during the outburst. The mHz QRM has a fractional rms of 10%--16% in the 8--35 keV energy band with a Q factor (frequency/width) of 2--4. Benefiting from the broad energy band of hxmt, we study the energy dependence of the 60 mHz QRM in 1--100 keV for the first time. We find that the fractional rms of the mHz QRM increases with photon energy, while the time lags of the mHz QRM are soft and decrease with photon energy. Fast recurrence of the mHz QRM, in a timescale of less than one hour, has been observed during the outburst. During this period, the corresponding energy spectra moderately change when the source transitions from the QRM state to the non-QRM state. The QRM phenomena also shows a dependence with the accretion rate. We suggest that the QRM could be caused by an unknown accretion instability aroused from the corona.

astro-ph.HE

Quasi-periodic oscillations of the X-ray burst from the magnetar SGR J1935+2154 and associated with the fast radio burst FRB 200428

The origin(s) and mechanism(s) of fast radio bursts (FRBs), which are short radio pulses from cosmological distances, have remained a major puzzle since their discovery. We report a strong Quasi-Periodic Oscillation(QPO) of 40 Hz in the X-ray burst from the magnetar SGR J1935+2154 and associated with FRB 200428, significantly detected with the Hard X-ray Modulation Telescope (Insight-HXMT) and also hinted by the Konus-Wind data. QPOs from magnetar bursts have only been rarely detected; our 3.4 sigma (p-value is 2.9e-4) detection of the QPO reported here reveals the strongest QPO signal observed from magnetars (except in some very rare giant flares), making this X-ray burst unique among magnetar bursts. The two X-ray spikes coinciding with the two FRB pulses are also among the peaks of the QPO. Our results suggest that at least some FRBs are related to strong oscillation processes of neutron stars. We also show that we may overestimate the significance of the QPO signal and underestimate the errors of QPO parameters if QPO exists only in a fraction of the time series of a X-ray burst which we use to calculate the Leahy-normalized periodogram.

astro-ph.HE

Insight-HXMT observations of jet-like corona in a black hole X-ray binary MAXI J1820+070

A black hole X-ray binary produces hard X-ray radiation from its corona and disk when the accreting matter heats up. During an outburst, the disk and corona co-evolves with each other. However, such an evolution is still unclear in both its geometry and dynamics. Here we report the unusual decrease of the reflection fraction in MAXI J1820+070, which is the ratio of the coronal intensity illuminating the disk to the coronal intensity reaching the observer, as the corona is observed to contrast during the decay phase. We postulate a jet-like corona model, in which the corona can be understood as a standing shock where the material flowing through. In this dynamical scenario, the decrease of the reflection fraction is a signature of the corona's bulk velocity. Our findings suggest that as the corona is observed to get closer to the black hole, the coronal material might be outflowing faster.

astro-ph.HE

The design of the Ali CMB Polarization Telescope receiver

Ali CMB Polarization Telescope (AliCPT-1) is the first CMB degree-scale polarimeter to be deployed on the Tibetan plateau at 5,250m above sea level. AliCPT-1 is a 90/150 GHz 72 cm aperture, two-lens refracting telescope cooled down to 4 K. Alumina lenses, 800mm in diameter, image the CMB in a 33.4° field of view on a 636mm wide focal plane. The modularized focal plane consists of dichroic polarization-sensitive Transition-Edge Sensors (TESes). Each module includes 1,704 optically active TESes fabricated on a 150mm diameter silicon wafer. Each TES array is read out with a microwave multiplexing readout system capable of a multiplexing factor up to 2,048. Such a large multiplexing factor has allowed the practical deployment of tens of thousands of detectors, enabling the design of a receiver that can operate up to 19 TES arrays for a total of 32,376 TESes. AliCPT-1 leverages the technological advancements in the detector design from multiple generations of previously successful feedhorn-coupled polarimeters, and in the instrument design from BICEP-3, but applied on a larger scale. The cryostat receiver is currently under integration and testing. During the first deployment year, the focal plane will be populated with up to 4 TES arrays. Further TES arrays will be deployed in the following years, fully populating the focal plane with 19 arrays on the fourth deployment year. Here we present the AliCPT-1 receiver design, and how the design has been optimized to meet the experimental requirements.

astro-ph.IM

Design and Calibration of the High Energy Particle Monitor onboard the Insight-HXMT

Three high energy particle monitors (HPMs) employed onboard the Hard X-ray Modulation Telescope Insight-HXMT) can detect the charged particles from South Atlantic Anomaly (SAA) and hence provide the alert trigger for switch-on/off of the main detectors. Here a typical design of HPM with high stability and reliability is adopted by taking a plastic scintillator coupled with a small photomultiplier tube (PMT). The window threshold of HPM is designed as 1 MeV and 20 MeV for the incident electron and proton, respectively. Before the launch of Insight-HXMT, we performed in details the ground calibration of HPM. The measured energy response and its dependence on temperature are taken as essential input of Geant4 simulation for estimating the HPM count rate given with an incident particle energy spectrum. This serves as a guidance for choosing a reasonable working range of the PMT high voltage once the real SAA count rate is measured by HPM in orbit. So far the three HPMs have been working in orbit for more than two years. Apart from providing reliable alert trigger, the HPMs data are used as well to map the SAA region.

physics.ins-det

Insight-HXMT observations of Swift J0243.6+6124 during its 2017-2018 outburst

The recently discovered neutron star transient Swift J0243.6+6124 has been monitored by {\it the Hard X-ray Modulation Telescope} ({\it Insight-\rm HXMT). Based on the obtained data, we investigate the broadband spectrum of the source throughout the outburst. We estimate the broadband flux of the source and search for possible cyclotron line in the broadband spectrum. No evidence of line-like features is, however, found up to $\rm 150~keV$. In the absence of any cyclotron line in its energy spectrum, we estimate the magnetic field of the source based on the observed spin evolution of the neutron star by applying two accretion torque models. In both cases, we get consistent results with $B\rm \sim 10^{13}~G$, $D\rm \sim 6~kpc$ and peak luminosity of $\rm >10^{39}~erg~s^{-1}$ which makes the source the first Galactic ultraluminous X-ray source hosting a neutron star.

astro-ph.HE

A novel analog power supply for gain control of the Multi-Pixel Photon Counter (MPPC)

Silicon Photo-Multipliers (SiPM) are regarded as novel photo-detectors to replace conventional Photo-Multiplier Tubes (PMTs). However, the breakdown voltage dependence on the ambient temperature results in a gain variation of $\sim$3$\% /^{\circ} \mathrm C$. This severely limits the application of this device in experiments with wide range of operating temperature, especially in space missions. An experimental setup was established to investigate the temperature and bias voltage dependence of gain for the Multi-Pixel Photon Counter (MPPC). The gain and breakdown voltage dependence on operating temperature of an MPPC can be approximated by a linear function, which is similar to the behavior of a zener diode. The measured temperature coefficient of the breakdown voltage is $(59.4 \pm 0.4$ mV)$/^{\circ} \mathrm C$. According to this fact, an analog power supply based on two zener diodes and an operational amplifier was designed with a positive temperature coefficient. The measured temperature dependence for the designed power supply is between 63.65 to 64.61~mV/$^{\circ} \mathrm C$ at different output voltages. The designed power supply can bias the MPPC at an over-voltage with a temperature variation of $\sim$ 5~mV$/^{\circ} \mathrm C$. The gain variation of the MPPC biased at over-voltage of 2~V was reduced from 2.8$\% /^{\circ} \mathrm C$ to 0.3$\% /^{\circ} \mathrm C$ when biased the MPPC with the designed power supply for gain control. Detailed design and performance of the analog power supply in the temperature range from -42.7$^{\circ}\mathrm{C}$ to 20.9$^{\circ}\mathrm{C}$ will be discussed in this paper.

astro-ph.IM