Cine cone beam CT reconstruction using low-rank matrix factorization: algorithm and a proof-of-princple study

Respiration-correlated CBCT, commonly called 4DCBCT, provide respiratory phase-resolved CBCT images. In many clinical applications, it is more preferable to reconstruct true 4DCBCT with the 4th dimension being time, i.e., each CBCT image is reconstructed based on the corresponding instantaneous projection. We propose in this work a novel algorithm for the reconstruction of this truly time-resolved CBCT, called cine-CBCT, by effectively utilizing the underlying temporal coherence, such as periodicity or repetition, in those cine-CBCT images. Assuming each column of the matrix $\bm{U}$ represents a CBCT image to be reconstructed and the total number of columns is the same as the number of projections, the central idea of our algorithm is that the rank of $\bm{U}$ is much smaller than the number of projections and we can use a matrix factorization form $\bm{U}=\bm{L}\bm{R}$ for $\bm{U}$. The number of columns for the matrix $\bm{L}$ constraints the rank of $\bm{U}$ and hence implicitly imposing a temporal coherence condition among all the images in cine-CBCT. The desired image properties in $\bm{L}$ and the periodicity of the breathing pattern are achieved by penalizing the sparsity of the tight wavelet frame transform of $\bm{L}$ and that of the Fourier transform of $\bm{R}$, respectively. A split Bregman method is used to solve the problem. In this paper we focus on presenting this new algorithm and showing the proof of principle using simulation studies on an NCAT phantom.

physics.med-ph↗

A comprehensive study on the relationship between image quality and imaging dose in low-dose cone beam CT

While compressed sensing (CS) based reconstructions have been developed for low-dose CBCT, a clear understanding on the relationship between the image quality and imaging dose at low dose levels is needed. In this paper, we qualitatively investigate this subject in a comprehensive manner with extensive experimental and simulation studies. The basic idea is to plot image quality and imaging dose together as functions of number of projections and mAs per projection over the whole clinically relevant range. A clear understanding on the tradeoff between image quality and dose can be achieved and optimal low-dose CBCT scan protocols can be developed for various imaging tasks in IGRT. Main findings of this work include: 1) Under the CS framework, image quality has little degradation over a large dose range, and the degradation becomes evident when the dose < 100 total mAs. A dose < 40 total mAs leads to a dramatic image degradation. Optimal low-dose CBCT scan protocols likely fall in the dose range of 40-100 total mAs, depending on the specific IGRT applications. 2) Among different scan protocols at a constant low-dose level, the super sparse-view reconstruction with projection number less than 50 is the most challenging case, even with strong regularization. Better image quality can be acquired with other low mAs protocols. 3) The optimal scan protocol is the combination of a medium number of projections and a medium level of mAs/view. This is more evident when the dose is around 72.8 total mAs or below and when the ROI is a low-contrast or high-resolution object. Based on our results, the optimal number of projections is around 90 to 120. 4) The clinically acceptable lowest dose level is task dependent. In our study, 72.8mAs is a safe dose level for visualizing low-contrast objects, while 12.2 total mAs is sufficient for detecting high-contrast objects of diameter greater than 3 mm.

physics.med-ph↗

Four-dimensional Cone Beam CT Reconstruction and Enhancement using a Temporal Non-Local Means Method

Four-dimensional Cone Beam Computed Tomography (4D-CBCT) has been developed to provide respiratory phase resolved volumetric imaging in image guided radiation therapy (IGRT). Inadequate number of projections in each phase bin results in low quality 4D-CBCT images with obvious streaking artifacts. In this work, we propose two novel 4D-CBCT algorithms: an iterative reconstruction algorithm and an enhancement algorithm, utilizing a temporal nonlocal means (TNLM) method. We define a TNLM energy term for a given set of 4D-CBCT images. Minimization of this term favors those 4D-CBCT images such that any anatomical features at one spatial point at one phase can be found in a nearby spatial point at neighboring phases. 4D-CBCT reconstruction is achieved by minimizing a total energy containing a data fidelity term and the TNLM energy term. As for the image enhancement, 4D-CBCT images generated by the FDK algorithm are enhanced by minimizing the TNLM function while keeping the enhanced images close to the FDK results. A forward-backward splitting algorithm and a Gauss-Jacobi iteration method are employed to solve the problems. The algorithms are implemented on GPU to achieve a high computational efficiency. The reconstruction algorithm and the enhancement algorithm generate visually similar 4D-CBCT images, both better than the FDK results. Quantitative evaluations indicate that, compared with the FDK results, our reconstruction method improves contrast-to-noise-ratio (CNR) by a factor of 2.56~3.13 and our enhancement method increases the CNR by 2.75~3.33 times. The enhancement method also removes over 80% of the streak artifacts from the FDK results. The total computation time is ~460 sec for the reconstruction algorithm and ~610 sec for the enhancement algorithm on an NVIDIA Tesla C1060 GPU card.

physics.med-ph↗

Fast Monte Carlo Simulation for Patient-specific CT/CBCT Imaging Dose Calculation

Recently, X-ray imaging dose from computed tomography (CT) or cone beam CT (CBCT) scans has become a serious concern. Patient-specific imaging dose calculation has been proposed for the purpose of dose management. While Monte Carlo (MC) dose calculation can be quite accurate for this purpose, it suffers from low computational efficiency. In response to this problem, we have successfully developed a MC dose calculation package, gCTD, on GPU architecture under the NVIDIA CUDA platform for fast and accurate estimation of the x-ray imaging dose received by a patient during a CT or CBCT scan. Techniques have been developed particularly for the GPU architecture to achieve high computational efficiency. Dose calculations using CBCT scanning geometry in a homogeneous water phantom and a heterogeneous Zubal head phantom have shown good agreement between gCTD and EGSnrc, indicating the accuracy of our code. In terms of improved efficiency, it is found that gCTD attains a speed-up of ~400 times in the homogeneous water phantom and ~76.6 times in the Zubal phantom compared to EGSnrc. As for absolute computation time, imaging dose calculation for the Zubal phantom can be accomplished in ~17 sec with the average relative standard deviation of 0.4%. Though our gCTD code has been developed and tested in the context of CBCT scans, with simple modification of geometry it can be used for assessing imaging dose in CT scans as well.

physics.med-ph↗

GPU-based fast Monte Carlo simulation for radiotherapy dose calculation

Monte Carlo (MC) simulation is commonly considered to be the most accurate dose calculation method in radiotherapy. However, its efficiency still requires improvement for many routine clinical applications. In this paper, we present our recent progress towards the development a GPU-based MC dose calculation package, gDPM v2.0. It utilizes the parallel computation ability of a GPU to achieve high efficiency, while maintaining the same particle transport physics as in the original DPM code and hence the same level of simulation accuracy. In GPU computing, divergence of execution paths between threads can considerably reduce the efficiency. Since photons and electrons undergo different physics and hence attain different execution paths, we use a simulation scheme where photon transport and electron transport are separated to partially relieve the thread divergence issue. High performance random number generator and hardware linear interpolation are also utilized. We have also developed various components to handle fluence map and linac geometry, so that gDPM can be used to compute dose distributions for realistic IMRT or VMAT treatment plans. Our gDPM package is tested for its accuracy and efficiency in both phantoms and realistic patient cases. In all cases, the average relative uncertainties are less than 1%. A statistical t-test is performed and the dose difference between the CPU and the GPU results is found not statistically significant in over 96% of the high dose region and over 97% of the entire region. Speed up factors of 69.1 ~ 87.2 have been observed using an NVIDIA Tesla C2050 GPU card against a 2.27GHz Intel Xeon CPU processor. For realistic IMRT and VMAT plans, MC dose calculation can be completed with less than 1% standard deviation in 36.1~39.6 sec using gDPM.

physics.med-ph↗

GPU-based Iterative Cone Beam CT Reconstruction Using Tight Frame Regularization

X-ray imaging dose from serial cone-beam CT (CBCT) scans raises a clinical concern in most image guided radiation therapy procedures. It is the goal of this paper to develop a fast GPU-based algorithm to reconstruct high quality CBCT images from undersampled and noisy projection data so as to lower the imaging dose. For this purpose, we have developed an iterative tight frame (TF) based CBCT reconstruction algorithm. A condition that a real CBCT image has a sparse representation under a TF basis is imposed in the iteration process as regularization to the solution. To speed up the computation, a multi-grid method is employed. Our GPU implementation has achieved high computational efficiency and a CBCT image of resolution 512\times512\times70 can be reconstructed in ~5 min. We have tested our algorithm on a digital NCAT phantom and a physical Catphan phantom. It is found that our TF-based algorithm is able to reconstrct CBCT in the context of undersampling and low mAs levels. We have also quantitatively analyzed the reconstructed CBCT image quality in terms of modulation-transfer-function and contrast-to-noise ratio under various scanning conditions. The results confirm the high CBCT image quality obtained from our TF algorithm. Moreover, our algorithm has also been validated in a real clinical context using a head-and-neck patient case. Comparisons of the developed TF algorithm and the current state-of-the-art TV algorithm have also been made in various cases studied in terms of reconstructed image quality and computation efficiency.

physics.med-ph↗

A GPU-based finite-size pencil beam algorithm with 3D-density correction for radiotherapy dose calculation

Targeting at the development of an accurate and efficient dose calculation engine for online adaptive radiotherapy, we have implemented a finite size pencil beam (FSPB) algorithm with a 3D-density correction method on GPU. This new GPU-based dose engine is built on our previously published ultrafast FSPB computational framework [Gu et al. Phys. Med. Biol. 54 6287-97, 2009]. Dosimetric evaluations against Monte Carlo dose calculations are conducted on 10 IMRT treatment plans (5 head-and-neck cases and 5 lung cases). For all cases, there is improvement with the 3D-density correction over the conventional FSPB algorithm and for most cases the improvement is significant. Regarding the efficiency, because of the appropriate arrangement of memory access and the usage of GPU intrinsic functions, the dose calculation for an IMRT plan can be accomplished well within 1 second (except for one case) with this new GPU-based FSPB algorithm. Compared to the previous GPU-based FSPB algorithm without 3D-density correction, this new algorithm, though slightly sacrificing the computational efficiency (~5-15% lower), has significantly improved the dose calculation accuracy, making it more suitable for online IMRT replanning.

physics.med-ph↗

3D tumor localization through real-time volumetric x-ray imaging for lung cancer radiotherapy

Recently we have developed an algorithm for reconstructing volumetric images and extracting 3D tumor motion information from a single x-ray projection. We have demonstrated its feasibility using a digital respiratory phantom with regular breathing patterns. In this work, we present a detailed description and a comprehensive evaluation of the improved algorithm. The algorithm was improved by incorporating respiratory motion prediction. The accuracy and efficiency were then evaluated on 1) a digital respiratory phantom, 2) a physical respiratory phantom, and 3) five lung cancer patients. These evaluation cases include both regular and irregular breathing patterns that are different from the training dataset. For the digital respiratory phantom with regular and irregular breathing, the average 3D tumor localization error is less than 1 mm. On an NVIDIA Tesla C1060 GPU card, the average computation time for 3D tumor localization from each projection ranges between 0.19 and 0.26 seconds, for both regular and irregular breathing, which is about a 10% improvement over previously reported results. For the physical respiratory phantom, an average tumor localization error below 1 mm was achieved with an average computation time of 0.13 and 0.16 seconds on the same GPU card, for regular and irregular breathing, respectively. For the five lung cancer patients, the average tumor localization error is below 2 mm in both the axial and tangential directions. The average computation time on the same GPU card ranges between 0.26 and 0.34 seconds.

physics.med-ph↗

Beam Orientation Optimization for Intensity Modulated Radiation Therapy using Adaptive l1 Minimization

Beam orientation optimization (BOO) is a key component in the process of IMRT treatment planning. It determines to what degree one can achieve a good treatment plan quality in the subsequent plan optimization process. In this paper, we have developed a BOO algorithm via adaptive l_1 minimization. Specifically, we introduce a sparsity energy function term into our model which contains weighting factors for each beam angle adaptively adjusted during the optimization process. Such an energy term favors small number of beam angles. By optimizing a total energy function containing a dosimetric term and the sparsity term, we are able to identify the unimportant beam angles and gradually remove them without largely sacrificing the dosimetric objective. In one typical prostate case, the convergence property of our algorithm, as well as the how the beam angles are selected during the optimization process, is demonstrated. Fluence map optimization (FMO) is then performed based on the optimized beam angles. The resulted plan quality is presented and found to be better than that obtained from unoptimized (equiangular) beam orientations. We have further systematically validated our algorithm in the contexts of 5-9 coplanar beams for 5 prostate cases and 1 head and neck case. For each case, the final FMO objective function value is used to compare the optimized beam orientations and the equiangular ones. It is found that, our BOO algorithm can lead to beam configurations which attain lower FMO objective function values than corresponding equiangular cases, indicating the effectiveness of our BOO algorithm.

physics.med-ph↗

GPU-based Low Dose CT Reconstruction via Edge-preserving Total Variation Regularization

High radiation dose in CT scans increases a lifetime risk of cancer and has become a major clinical concern. Recently, iterative reconstruction algorithms with Total Variation (TV) regularization have been developed to reconstruct CT images from highly undersampled data acquired at low mAs levels in order to reduce the imaging dose. Nonetheless, TV regularization may lead to over-smoothed images and lost edge information. To solve this problem, in this work we develop an iterative CT reconstruction algorithm with edge-preserving TV regularization to reconstruct CT images from highly undersampled data obtained at low mAs levels. The CT image is reconstructed by minimizing an energy consisting of an edge-preserving TV norm and a data fidelity term posed by the x-ray projections. The edge-preserving TV term is proposed to preferentially perform smoothing only on non-edge part of the image in order to avoid over-smoothing, which is realized by introducing a penalty weight to the original total variation norm. Our iterative algorithm is implemented on GPU to improve its speed. We test our reconstruction algorithm on a digital NCAT phantom, a physical chest phantom, and a Catphan phantom. Reconstruction results from a conventional FBP algorithm and a TV regularization method without edge preserving penalty are also presented for comparison purpose. The experimental results illustrate that both TV-based algorithm and our edge-preserving TV algorithm outperform the conventional FBP algorithm in suppressing the streaking artifacts and image noise under the low dose context. Our edge-preserving algorithm is superior to the TV-based algorithm in that it can preserve more information of fine structures and therefore maintain acceptable spatial resolution.

physics.med-ph↗

GPU-based Low-dose 4DCT Reconstruction via Temporal Non-local Means

Four-dimensional computed tomography (4DCT) has been widely used in cancer radiotherapy for accurate target delineation and motion measurement for tumors in thorax and upper abdomen areas. However, 4DCT simulation is associated with much higher imaging dose than conventional CT simulation, which is a major concern in its clinical application. Conventionally, each phase of 4DCT is reconstructed independently using the filtered backprojection (FBP) algorithm. The basic idea of our new algorithm is that, by utilizing the common information among different phases, the input information required to reconstruct image of high quality, and thus the imaging dose, can be reduced. We proposed a temporal non-local means (TNLM) method to explore the inter-phase similarity. All phases of the 4DCT images are reconstructed simultaneously by minimizing a cost function consisting of a data fidelity term and a TNLM regularization term. We utilized a forward-backward splitting algorithm and a Gauss-Jacobi iteration method to efficiently solve the minimization problem. The algorithm was also implemented on graphics processing unit (GPU) to achieve a high computational speed. Our reconstruction algorithm has been tested on a digital NCAT thorax phantom in three low dose scenarios. Our new algorithm generates visually much better CT images containing less image noise and streaking artifacts compared with the standard FBP algorithm. Quantitative analysis shows that much higher contrast-to-noise ratio and signal-to-noise ratio can be obtained using our algorithm. The total reconstruction time for all 10 phases of a slice ranges from 90 to 140 seconds on an NVIDIA Tesla C1060 GPU card.

physics.med-ph↗

GPU-based fast gamma index calcuation

The gamma-index dose comparison tool has been widely used to compare dose distributions in cancer radiotherapy. The accurate calculation of gamma-index requires an exhaustive search of the closest Euclidean distance in the high-resolution dose-distance space. This is a computational intensive task when dealing with 3D dose distributions. In this work, we combine a geometric method with a radial pre-sorting technique , and implement them on computer graphics processing units (GPUs). The developed GPU-based gamma-index computational tool is evaluated on eight pairs of IMRT dose distributions. The GPU implementation achieved 20x~30x speedup factor compared to CPU implementation and gamma-index calculations can be finished within a few seconds for all 3D testing cases. We further investigated the effect of various factors on both CPU and GPU computation time. The strategy of pre-sorting voxels based on their dose difference values speed up the GPU calculation by about 2-4 times. For n-dimensional dose distributions, gamma-index calculation time on CPU is proportional to the summation of gamma^n over all voxels, while that on GPU is effected by gamma^n distributions and is approximately proportional to the gamma^n summation over all voxels. We found increasing dose distributions resolution leads to quadratic increase of computation time on CPU, while less-than-quadratic increase on GPU. The values of dose difference (DD) and distance-to-agreement (DTA) criteria also have their impact on gamma-index calculation time.

physics.med-ph↗

Quantum oscillations in electron doped high temperature superconductors

Quantum oscillations in hole doped high temperature superconductors are difficult to understand within the prevailing views. An emerging idea is that of a putative normal ground state, which appears to be a Fermi liquid with a reconstructed Fermi surface. The oscillations are due to formation of Landau levels. Recently the same oscillations were found in the electron doped cuprate, $\mathrm{Nd_{2-x}Ce_{x}CuO_{4}}$, in the optimal to overdoped regime. Although these electron doped non-stoichiometric materials are naturally more disordered, they strikingly complement the hole doped cuprates. Here we provide an explanation of these observations from the perspective of density waves using a powerful transfer matrix method to compute the conductance as a function of the magnetic field.

cond-mat.supr-con↗

Ultra-fast treatment plan optimization for volumetric modulated arc therapy (VMAT)

Purpose: To develop a novel aperture-based algorithm for volumetric modulated arc therapy (VMAT) treatment plan optimization with high quality and high efficiency. Methods: The VMAT optimization problem is formulated as a large-scale convex programming problem solved by a column generation approach. We consider a cost function consisting two terms, the first which enforces a desired dose distribution while the second guarantees a smooth dose rate variation between successive gantry angles. At each iteration of the column generation method, a subproblem is first solved to generate one more deliverable MLC aperture which potentially decreases the cost function most effectively. A subsequent master problem is then solved to determine the dose rate at all currently generated apertures by minimizing the cost function. The iteration of such an algorithm yields a set of deliverable apertures, as well as dose rates, at all gantry angles. Results: The algorithm was preliminarily tested on five prostate and five head-and-neck clinical cases, each with one full gantry rotation and without any couch/collimator rotations. Compared to corresponding co-planar IMRT treatment plans (9 fields for prostate cases and 5 fields for head-and-neck cases), the VMAT plans delivered much lower doses to critical structures and more conformal doses to targets. Moreover, extremely high efficiency has been achieved in our algorithm. It takes only 5~8 minutes on CPU (MATLAB code on an Intel Xeon 2.27 GHz CPU) and 18~31 seconds on GPU (CUDA code on an NVIDIA Tesla C1060 GPU card) to generate such a plan. Conclusions: We have developed an aperture-based VMAT optimization algorithm which can generate clinically deliverable and high quality treatment plans at very high efficiency.

physics.med-ph↗

GPU-based Fast Low-dose Cone Beam CT Reconstruction via Total Variation

Cone-beam CT (CBCT) has been widely used in image guided radiation therapy (IGRT) to acquire updated volumetric anatomical information before treatment fractions for accurate patient alignment purpose. However, the excessive x-ray imaging dose from serial CBCT scans raises a clinical concern in most IGRT procedures. The excessive imaging dose can be effectively reduced by reducing the number of x-ray projections and/or lowering mAs levels in a CBCT scan. The goal of this work is to develop a fast GPU-based algorithm to reconstruct high quality CBCT images from undersampled and noisy projection data so as to lower the imaging dose. The CBCT is reconstructed by minimizing an energy functional consisting of a data fidelity term and a total variation regularization term. We developed a GPU-friendly version of the forward-backward splitting algorithm to solve this model. A multi-grid technique is also employed. We test our CBCT reconstruction algorithm on a digital NCAT phantom and a head-and-neck patient case. The performance under low mAs is also validated using a physical Catphan phantom and a head-and-neck Rando phantom. It is found that 40 x-ray projections are sufficient to reconstruct CBCT images with satisfactory quality for IGRT patient alignment purpose. Phantom experiments indicated that CBCT images can be successfully reconstructed with our algorithm under as low as 0.1 mAs/projection level. Comparing with currently widely used full-fan head-and-neck scanning protocol of about 360 projections with 0.4 mAs/projection, it is estimated that an overall 36 times dose reduction has been achieved with our algorithm. Moreover, the reconstruction time is about 130 sec on an NVIDIA Tesla C1060 GPU card, which is estimated ~100 times faster than similar iterative reconstruction approaches.

physics.med-ph↗

Real-time volumetric image reconstruction and 3D tumor localization based on a single x-ray projection image for lung cancer radiotherapy

Purpose: To develop an algorithm for real-time volumetric image reconstruction and 3D tumor localization based on a single x-ray projection image for lung cancer radiotherapy. Methods: Given a set of volumetric images of a patient at N breathing phases as the training data, we perform deformable image registration between a reference phase and the other N-1 phases, resulting in N-1 deformation vector fields (DVFs). These DVFs can be represented efficiently by a few eigenvectors and coefficients obtained from principal component analysis (PCA). By varying the PCA coefficients, we can generate new DVFs, which, when applied on the reference image, lead to new volumetric images. We then can reconstruct a volumetric image from a single projection image by optimizing the PCA coefficients such that its computed projection matches the measured one. The 3D location of the tumor can be derived by applying the inverted DVF on its position in the reference image. Our algorithm was implemented on graphics processing units (GPUs) to achieve real-time efficiency. We generated the training data using a realistic and dynamic mathematical phantom with 10 breathing phases. The testing data were 360 cone beam projections corresponding to one gantry rotation, simulated using the same phantom with a 50% increase in breathing amplitude. Results: The average relative image intensity error of the reconstructed volumetric images is 6.9% +/- 2.4%. The average 3D tumor localization error is 0.8 mm +/- 0.5 mm. On an NVIDIA Tesla C1060 GPU card, the average computation time for reconstructing a volumetric image from each projection is 0.24 seconds (range: 0.17 and 0.35 seconds). Conclusions: We have shown the feasibility of reconstructing volumetric images and localizing tumor positions in 3D in near real-time from a single x-ray image.

physics.med-ph↗

GPU-based ultra-fast direct aperture optimization for online adaptive radiation therapy

Online adaptive radiation therapy (ART) has great promise to significantly reduce normal tissue toxicity and/or improve tumor control through real-time treatment adaptations based on the current patient anatomy. However, the major technical obstacle for clinical realization of online ART, namely the inability to achieve real-time efficiency in treatment re-planning, has yet to be solved. To overcome this challenge, this paper presents our work on the implementation of an intensity modulated radiation therapy (IMRT) direct aperture optimization (DAO) algorithm on graphics processing unit (GPU) based on our previous work on CPU. We formulate the DAO problem as a large-scale convex programming problem, and use an exact method called column generation approach to deal with its extremely large dimensionality on GPU. Five 9-field prostate and five 5-field head-and-neck IMRT clinical cases with 5\times5 mm2 beamlet size and 2.5\times2.5\times2.5 mm3 voxel size were used to evaluate our algorithm on GPU. It takes only 0.7~2.5 seconds for our implementation to generate optimal treatment plans using 50 MLC apertures on an NVIDIA Tesla C1060 GPU card. Our work has therefore solved a major problem in developing ultra-fast (re-)planning technologies for online ART.

physics.med-ph↗

Development of a GPU-based Monte Carlo dose calculation code for coupled electron-photon transport

Monte Carlo simulation is the most accurate method for absorbed dose calculations in radiotherapy. Its efficiency still requires improvement for routine clinical applications, especially for online adaptive radiotherapy. In this paper, we report our recent development on a GPU-based Monte Carlo dose calculation code for coupled electron-photon transport. We have implemented the Dose Planning Method (DPM) Monte Carlo dose calculation package (Sempau et al, Phys. Med. Biol., 45(2000)2263-2291) on GPU architecture under CUDA platform. The implementation has been tested with respect to the original sequential DPM code on CPU in phantoms with water-lung-water or water-bone-water slab geometry. A 20 MeV mono-energetic electron point source or a 6 MV photon point source is used in our validation. The results demonstrate adequate accuracy of our GPU implementation for both electron and photon beams in radiotherapy energy range. Speed up factors of about 5.0 ~ 6.6 times have been observed, using an NVIDIA Tesla C1060 GPU card against a 2.27GHz Intel Xeon CPU processor.

physics.med-ph↗