SearcharxivSearch

arXiv subjects

Y. D. Kim

Publications and source records attributed to Y. D. Kim.

At least 19 recordsLinked to original sources

Search for dark matter particle interactions in an extended nuclear recoil energy window with the LUX-ZEPLIN (LZ) experiment

We report on a search for dark matter particles interacting with xenon nuclei in an exposure of 2.84 tonne-years with the LUX-ZEPLIN (LZ) experiment. An extended nuclear recoil energy window up to approximately 270 keV enables searches for effective field theory and inelastic models of dark matter where high-energy recoils account for a larger fraction of the predicted recoil spectrum compared to the nominal spin independent interaction. We observe one event with characteristics consistent with a nuclear recoil of $248\pm23\,\mathrm{(stat)}\pm23\,\mathrm{(sys)}$ keV, in a region where the known background expectation is low. A profile likelihood ratio test finds tension with the background-only hypothesis at a global significance of 2.6$σ$ when accounting for look-elsewhere effects, with a maximum local significance of 3.4$σ$ across the models tested. We describe the analysis and event of interest, the background model used in the statistical inference, and detail several of the rare background topologies considered.

hep-ex

Pushing the Limits of Pulse Shape Discrimination in a Large Liquid Xenon Detector

The LUX-ZEPLIN (LZ) experiment is a direct-detection dark matter experiment, optimized to search for weakly interacting massive particles (WIMPs) through WIMP-nucleon interactions. The main challenge in dark matter detection is differentiating between WIMP signals and background events. In LZ, the ratio of ionization to scintillation signals (charge-to-light) is the primary method for rejecting electronic recoil (ER) background. Pulse shape discrimination (PSD) offers a method for additional ER backgrounds rejection in liquid xenon detectors. In this paper, the discrimination power of PSD with the LZ experiment is discussed. To precisely characterize the scintillation pulse shape, an analysis framework is developed to reconstruct the detection time of individual photons. Using LZ calibration data, the photon-timing prompt fraction discriminator is optimized and achieves ER leakage as low as $15\%$. For specific background processes such as $^{124}$Xe double electron capture, the leakage is reduced further to about $5\%$. PSD is combined with charge-to-light to form two-factor discrimination (TFD). The optimized TFD performance is compared with the performance of the charge-to-light method, with the corresponding false positive rate reduced by up to a factor of two for large scintillation pulses. Finally, PSD and TFD are applied to data from LZ's WS2024 run and their performance is summarized.

physics.ins-det

Flow-dependent tagging of $^{214}$Pb decays in the LZ dark matter detector

The LUX-ZEPLIN (LZ) experiment is searching for dark matter interactions in a liquid xenon time projection chamber (LXe-TPC). This article demonstrates how control of the flow state in the LXe-TPC enables the identification of pairs of sequential alpha-decays, which are used to map fluid flow and ion drift in the liquid target. The resulting transport model is used to tag \UChPb~ beta-decays, a leading background to dark matter signals in LZ. Temporally evolving volume selections, at a cost of 9.0\% of exposure, target the decay of each \UChPb~ atom up to 81 minutes after production, resulting in (63~$\pm$~6$_{(\mathrm{stat})}$~$\pm$~7$_{(\mathrm{sys})}$)\% identification of \UChPb~decays to ground state. We also demonstrate how flow-based tagging techniques enable a novel calibration side band that is concurrent with science data. Finally we report updated estimates of radon-chain charge branching fractions in liquid xenon, finding branching to $^{218}$Po$^+$ at $0.49 \pm 0.01$, $^{214}$Pb$^+$ at $0.48 \pm 0.12$, and $^{214}$Bi$^+$ at $0.74 \pm 0.05$, with a mean charged ion lifetime in the LZ TPC of $49 \pm 4$ min.

physics.ins-det

Development of a 10 mol% Rubidium-doped CsI Crystal for $^{87}$Rb Beta-Spectroscopy and Sterile Neutrino Searches

The third-forbidden non-unique beta-decay of $^{87}$Rb to $^{87}$Sr (Q$_β= 282.275(6)$ keV) has long served as an important benchmark for understanding forbidden beta-decay. To investigate this, we have developed a novel CsI scintillator with a 10 mol% Rb concentration using the Bridgman method. The incorporated $^{87}$Rb serves as an intrinsic radioactive source, enabling a source-in-detector configuration with high detection efficiency and minimal energy loss for low-energy electrons from beta-decay. We investigated both Rb doped and Tl co-doped CsI crystals and characterized their scintillation properties, including light yield, energy resolution, and non-linear response. We report distinct scintillation characteristics for the CsI:Rb and CsI:Tl,Rb crystals, with light yields of $1.38\pm0.01$ and $4.73\pm0.13$ PE/keV, respectively. Using the measured $^{87}$Rb beta-spectrum, we search for a keV-scale sterile neutrino admixture through the characteristic kink-like distortion induced by a heavy neutrino mass eigenstate. This study provides a basis for future sterile neutrino searches using rubidium doped CsI crystal.

physics.ins-det

Search for New Physics via Low-Energy Electron Recoils with a 4.2 Tonne\times Year Exposure from the LZ Experiment

We report results from searches for new physics models through electron recoils using data collected by the LUX-ZEPLIN (LZ) experiment during its first two science runs, with a total exposure of 4.2 tonne-years. The observed data are consistent with a background-only hypothesis. Constraints are derived for electromagnetic interactions of solar neutrinos, solar axion-like particles (ALPs), mirror dark matter, and the absorption of bosonic dark matter candidates. The inverse Primakoff process for 57Fe de-excitation solar ALPs is considered for the first time. These results represent the most stringent constraints to date on keV-scale Primakoff and 57Fe solar ALPs, bosonic dark matter, mirror dark matter, and neutrino millicharge, while remaining competitive for the other signal models investigated.

hep-ex

Searches for Light Dark Matter and Evidence of Coherent Elastic Neutrino-Nucleus Scattering of Solar Neutrinos with the LUX-ZEPLIN (LZ) Experiment

We present searches for light dark matter (DM) with masses 3-9 GeV/$c^2$ in the presence of coherent elastic neutrino-nucleus scattering (CE$ν$NS) from $^{8}$B solar neutrinos with the LUX-ZEPLIN experiment. This analysis uses a 5.7 tonne-year exposure with data collected between March 2023 and April 2025. In an energy range spanning 1-6 keV, we report no significant excess of events attributable to dark matter nuclear recoils, but we observe a significant signal from $^{8}$B CE$ν$NS interactions that is consistent with expectation. We set world-leading limits on spin-independent and spin-dependent-neutron DM-nucleon interactions for masses down to 5 GeV/$c^2$. In the no-dark-matter scenario, we observe a signal consistent with $^{8}$B CE$ν$NS events, corresponding to a $4.5σ$ statistical significance. This is the most significant evidence of $^{8}$B CE$ν$NS interactions and is enabled by robust background modeling and mitigation techniques. This demonstrates LZ's ability to detect rare signals at keV-scale energies.

hep-ex

Probing unexplored spin-dependent dark matter-proton coupling with few-photoelectron threshold in COSINE-100

We report new constraints on the spin-dependent scattering cross section between low-mass dark matter and protons using data collected by the COSINE-100 experiment. By implementing a specialized event selection process using a multi-layer perceptron and robust noise mitigation, this analysis pioneers a detection threshold of 3 and 4 isolated peaks, corresponding to the reconstructed photoelectrons, which are significantly lower than the 8 photoelectron threshold used in previous analyses. In this unstudied few-photoelectron regime, where instrumental noise and phosphorescence are prevalent, we utilize a phenomenological background model to search for the annual modulation signal expected from the Standard Halo Model. No statistically significant annual modulation is observed in our data. We derive new 90% confidence level (C.L.) upper limits for the spin-dependent DM-proton cross section, establishing the world's most stringent constraints in the 1.75-2.25 GeV/c$^2$ mass range. Furthermore, by incorporating the Migdal effect, we extend the experimental sensitivity to the sub-GeV/c$^2$ regime, setting world-leading limits in the 15-58 MeV/c$^2$ range. These results demonstrate the capability of NaI(Tl) target materials to probe previously unexplored regions of the dark matter parameter space.

hep-ex

A study of neutrinoless double electron capture in $^{40}$Ca from the AMoRE experiment

The search for neutrinoless double electron capture ($0ν\mathrm{2EC}$) provides a sensitive probe of lepton-number violation and the Majorana nature of neutrinos. We investigate the $0ν\mathrm{2EC}$ decay of $^{40}$Ca using cryogenic detectors equipped with metallic magnetic calorimeters in the AMoRE-I experiment. The analysis is based on a physics dataset corresponding to a total exposure of 7.32 kg$\cdot$yr from thirteen $^{40}$Ca$^{100}$MoO$_4$ crystals. No significant excess is observed, and a lower limit on the half-life is obtained as $T^{0ν}_{1/2} > 1.7 \times 10^{22}$ yr at 90$\%$ confidence level. An improved sensitivity is expected for the upcoming AMoRE-II experiment. These results demonstrate the potential of CaMoO$_4$ detectors to explore rare decay processes beyond the primary $^{100}$Mo $0νββ$ search program.

nucl-ex

Precision measurement of positron decay modes of Xe-125 in the LUX-ZEPLIN experiment

The radioisotope $^{125}\text{Xe}$ is a short-lived ($T_{1/2}\sim16.9 h$) activation product of the neutron calibrations performed in the LUX-ZEPLIN experiment. Subsequently, $^{125}$Xe decays primarily ($>99\%$) via electron capture, but positron emission has been confirmed by direct measurement to at least the 243 keV level of $^{125}\text{I}$. An additional decay to the 188keV level is expected from triple-coincident measurements of the annihilation and relaxation $γ$ rays, but has not been directly confirmed. By utilizing multiple-scatter event analysis and the pre-activation data to constrain backgrounds, this work reports positron emission with a statistical significance of 5.5$σ$. This corresponds to a total branching ratio of $0.29\pm0.08_{\text{stat.}}\pm0.04_{\text{sys.}}$ %, and is the first constraint to the individual branching levels of $^{125}\text{I}$.

hep-ex

Constraints on sub-GeV dark matter scattering on electrons with COSINE-100

We present results of the search for sub-GeV dark matter interaction with electrons in the NaI(Tl) crystals of the COSINE-100 experiment. The two benchmark scenarios of a heavy and a light vector boson as mediator of the interaction were studied. We found no excess events over the expected background in a data-set of 2.82 years, with a total exposure of 172.9 kg-year. The derived 90% confidence level upper limits exclude a DM-electron scattering cross section above 6.4 $\times$ 10$^{-33}$ cm$^2$ for a DM mass of 0.25 GeV, assuming a light mediator; and above 3.4 $\times$ 10$^{-37}$ cm$^2$ for a 0.4 GeV DM, assuming a heavy mediator, and represent the most stringent constraints for a NaI(Tl) target to date. We also briefly discuss a planned analysis using an annual modulation method below the current 0.7 keV threshold of COSINE-100, down to few photoelectrons yield.

hep-ex

Study of few-electron backgrounds in the LUX-ZEPLIN detector

The LUX-ZEPLIN (LZ) experiment aims to detect rare interactions between dark matter particles and xenon. Although the detector is designed to be the most sensitive to GeV/$c^2$--TeV/$c^2$ Weakly Interacting Massive Particles (WIMPs), it is also capable of measuring low-energy ionization signals down to a single electron that may be produced by scatters of sub-GeV/$c^2$ dark matter. The major challenge in exploiting this sensitivity is to understand and suppress the ionization background in the few-electron regime. We report a characterization of the delayed electron backgrounds following energy depositions in the LZ detector under different detector conditions. In addition, we quantify the probability for photons to be emitted in coincidence with electron emission from the high voltage grids. We then demonstrate that spontaneous grid electron emission can be identified and rejected with a high efficiency using a coincident photon tag, which provides a tool to improve the sensitivity of future dark matter searches.

physics.ins-det

Measurement of the Muon Flux at the Sanford Underground Research Facility with the LUX-ZEPLIN Dark Matter Detector

High-energy cosmic-ray muons reaching deep underground laboratories can cause events in detectors that mimic signals expected from dark matter particles, neutrinos, or rare decays. Knowledge of the muon flux and energy spectrum is important for evaluating the background rate caused by muons and their secondaries. In this paper, we report the measurement of the cosmic-ray muon flux in the Davis Campus of the Sanford Underground Research Facility with the LUX-ZEPLIN detector. Using 366.4~days of exposure, the muon rate through the detector was measured as $10.94\pm0.17_\textrm{stat.}~\textrm{day}^{-1}$ with energy thresholds of 20~MeV in the inner xenon detector and 8 MeV in the outer liquid scintillator detector. This rate corresponds to a muon flux of $(5.09\pm0.08_\textrm{stat.}\pm0.10_\textrm{sys.})\times10^{-9}~\textrm{cm}^{-2}\textrm{s}^{-1}$ in the Davis Cavern.

hep-ex

Limits on WIMP dark matter with NaI(Tl) crystals in three years of COSINE-100 data

We report limits on WIMP dark matter derived from three years of data collected by the COSINE-100 experiment with NaI(Tl) crystals, achieving an improved energy threshold of 0.7 keV. This lowered threshold enhances sensitivity in the sub-GeV mass range, extending the reach for direct detection of low-mass dark matter. Although no excess of WIMP-like events was observed, the increased sensitivity enabled a model-insensitive comparison between the expected WIMP signal rate-based on mass limits from our data-and DAMA's reported modulation amplitude. Our findings strongly disfavor the DAMA signal as originating from WIMP interactions, fully excluding DAMA/LIBRA 3$σ$ allowed regions and providing enhanced WIMP mass limits by an order of magnitude in the spin-independent model compared to previous results. In the spin-dependent model, cross-section upper limits were obtained in the mass range [0.1-5.0] GeV/c$^2$, with additional sensitivity to sub-GeV WIMPs through the inclusion of the Migdal effect. These results represent substantial progress in low-mass dark matter exploration and reinforce constraints on the longstanding DAMA claim.

hep-ex

Combined Annual Modulation Dark Matter Search with COSINE-100 and ANAIS-112

The annual modulation signal, claimed to be consistent with dark matter as observed by DAMA/LIBRA in a sodium-iodide based detector, has persisted for over two decades. COSINE-100 and ANAIS-112 were designed to test the claim directly using the same target material. COSINE-100, located at Yangyang Underground Laboratory in South Korea, and ANAIS-112, located at Canfranc Underground Laboratory in Spain, have been taking data since 2016 and 2017, respectively. Each experiment published its respective results independently. In this paper, we present the results of an annual modulation search as a test of the signal observed by DAMA/LIBRA with the first three respective years of data from COSINE-100 and ANAIS-112. Using a Markov Chain Monte Carlo method, we find best fit values for modulation amplitude of $-0.0002 {\pm} 0.0026$ cpd/kg/keV in the 1-6 keV and $0.0021 {\pm} 0.0028$ cpd/kg/keV in the 2-6 keV energy regions. These results are not compatible with DAMA/LIBRA's assertion for their observation of annual modulation at $3.7σ$ and $2.6σ$, respectively. Performing a simple combination of the newly released 6-years datasets from both experiments find values consistent with no modulation at $0.0005 {\pm} 0.0019$ cpd/kg/keV in the 1-6 keV and $0.0027 {\pm} 0.0021$ cpd/kg/keV in the 2-6 keV energy regions with $4.68σ$ and $3.53σ$ respective exclusions of the DAMA/LIBRA signal.

astro-ph.IM

Low-energy nuclear recoil calibration of the LUX-ZEPLIN experiment with a photoneutron source

The LZ experiment is a liquid xenon time-projection chamber (TPC) searching for evidence of particle dark matter interactions. In the simplest assumption of elastic scattering, many dark matter models predict an energy spectrum which rises quasi-exponentially with decreasing energy transfer to a target atom. LZ expects to detect coherent neutrino-nucleus scattering of $^{8}$B solar neutrinos, the signal from which is very similar to a dark matter particle with mass of about 5.5 GeV/$c^{2}$, which result in typical nuclear recoil energies of $<$5 keV$_{\text{nr}}$. Therefore, it is of crucial importance to calibrate the response of recoiling xenon nuclei to keV-energy recoils. This analysis details the first in situ photoneutron calibration of the LZ detector and probes its response in this energy regime.

physics.ins-det

COSINE-100 Full Dataset Challenges the Annual Modulation Signal of DAMA/LIBRA

For over 25 years, the DAMA/LIBRA collaboration has claimed to observe an annual modulation signal, suggesting the existence of dark matter interactions. However, no experiment employing different target materials has observed a dark matter signal consistent with their result. To address this puzzle, the COSINE-100 collaboration conducted a model-independent test using sodium iodide crystal detectors, the same target material as DAMA/LIBRA. Analyzing data collected over 6.4 years by the effective mass of 61.3 kg, with improved energy calibration and time-dependent background modeling, we found no evidence of an annual modulation signal, challenging the DAMA/LIBRA result with a confidence level greater than 3$σ$. This finding represents a substantial step toward resolving the long-standing debate surrounding DAMA/LIBRA's dark matter claim, indicating that the observed modulation is unlikely to be caused by dark matter interactions.

hep-ex

Dark Matter Search Results from 4.2 Tonne-Years of Exposure of the LUX-ZEPLIN (LZ) Experiment

We report results of a search for nuclear recoils induced by weakly interacting massive particle (WIMP) dark matter using the LUX-ZEPLIN (LZ) two-phase xenon time projection chamber. This analysis uses a total exposure of $4.2\pm0.1$ tonne-years from 280 live days of LZ operation, of which $3.3\pm0.1$ tonne-years and 220 live days are new. A technique to actively tag background electronic recoils from $^{214}$Pb $β$ decays is featured for the first time. Enhanced electron-ion recombination is observed in two-neutrino double electron capture decays of $^{124}$Xe, representing a noteworthy new background. After removal of artificial signal-like events injected into the data set to mitigate analyzer bias, we find no evidence for an excess over expected backgrounds. World-leading constraints are placed on spin-independent (SI) and spin-dependent WIMP-nucleon cross sections for masses $\geq$9 GeV/$c^2$. The strongest SI exclusion set is $2.2\times10^{-48}$ cm$^{2}$ at the 90% confidence level and the best SI median sensitivity achieved is $5.1\times10^{-48}$ cm$^{2}$, both for a mass of 40 GeV/$c^2$.

hep-ex

Radiopurity measurements of liquid scintillator for the COSINE-100 Upgrade

A new 2,400 L liquid scintillator has been produced for the COSINE-100 Upgrade, which is under construction at Yemilab for the next COSINE dark matter experiment phase. The linear-alkyl-benzene-based scintillator is designed to serve as a veto for NaI(Tl) crystal targets and a separate platform for rare event searches. We measured using a sample consisting of a custom-made 445 mL cylindrical Teflon container equipped with two 3-inch photomultiplier tubes. Analyses show activity levels of $0.091 \pm 0.042$ mBq/kg for $^{238}$U and $0.012 \pm 0.007$ mBq/kg for $^{232}$Th.

physics.ins-det