Searcharxiv⌕ Search

arXiv subjects

Y. D. Kim

Publications and source records attributed to Y. D. Kim.

At least 37 records · Page 2Linked to original sources

Radiopurity measurements of liquid scintillator for the COSINE-100 Upgrade

A new 2,400 L liquid scintillator has been produced for the COSINE-100 Upgrade, which is under construction at Yemilab for the next COSINE dark matter experiment phase. The linear-alkyl-benzene-based scintillator is designed to serve as a veto for NaI(Tl) crystal targets and a separate platform for rare event searches. We measured using a sample consisting of a custom-made 445 mL cylindrical Teflon container equipped with two 3-inch photomultiplier tubes. Analyses show activity levels of $0.091 \pm 0.042$ mBq/kg for $^{238}$U and $0.012 \pm 0.007$ mBq/kg for $^{232}$Th.

physics.ins-det↗

Measurements and models of enhanced recombination following inner-shell vacancies in liquid xenon

Electron-capture decays of $^{125}$Xe and $^{127}$Xe, and double-electron-capture decays of $^{124}$Xe, are backgrounds in searches for weakly interacting massive particles (WIMPs) conducted by dual-phase xenon time projection chambers such as LUX-ZEPLIN (LZ). These decays produce signals with more light and less charge than equivalent-energy $β$ decays, and correspondingly overlap more with WIMP signals. We measure three electron-capture charge yields in LZ: the 1.1~keV M-shell, 5.2~keV L-shell, and 33.2~keV K-shell at drift fields of 193 and 96.5~V/cm. The LL double-electron-capture decay of $^{124}$Xe exhibits even more pronounced shifts in charge and light. We provide a first model of double-electron-capture charge yields using the link between ionization density and electron-ion recombination, and identify a need for more accurate calculations. Finally, we discuss the implications of the reduced charge yield of these decays and other interactions creating inner-shell vacancies for future dark matter searches.

hep-ex↗

First constraint for atmospheric millicharged particles with the LUX-ZEPLIN experiment

We report on a search for millicharged particles (mCPs) produced in cosmic ray proton atmospheric interactions using data collected during the first science run of the LUX-ZEPLIN experiment. The mCPs produced by two processes -- meson decay and proton bremsstrahlung -- are considered in this study. This search utilized a novel signature unique to liquid xenon (LXe) time projection chambers (TPCs), allowing sensitivity to mCPs with masses ranging from 10 to 1000 MeV/c$^2$ and fractional charges between 0.001 and 0.02 of the electron charge e. With an exposure of 60 live days and a 5.5 tonne fiducial mass, we observed no significant excess over background. This represents the first experimental search for atmospheric mCPs and the first search for mCPs using an underground LXe experiment.

hep-ex↗

New constraints on cosmic ray-boosted dark matter from the LUX-ZEPLIN experiment

While dual-phase xenon time projection chambers (TPCs) have driven the sensitivity towards weakly interacting massive particles (WIMPs) at the GeV/c^2 to TeV/c^2 mass scale, the scope for sub-GeV/c^2 dark matter particles is hindered by a limited nuclear recoil energy detection threshold. One approach to probe for lighter candidates is to consider cases where they have been boosted by collisions with cosmic rays in the Milky Way, such that the additional kinetic energy lifts their induced signatures above the nominal threshold. In this Letter, we report first results of a search for cosmic ray-boosted dark matter (CRDM) with a combined 4.2 tonne-year exposure from the LUX-ZEPLIN (LZ) experiment. We observe no excess above the expected backgrounds and establish world-leading constraints on the spin-independent CRDM-nucleon cross section as small as 3.9 * 10^{-33} cm^2 at 90% confidence level for sub-GeV/c^2 masses.

hep-ex↗

Upgrading the COSINE-100 Experiment for Enhanced Sensitivity to Low-Mass Dark Matter Detection

The DAMA/LIBRA experiment has reported an annual modulation signal in NaI(Tl) detectors, which has been interpreted as a possible indication of dark matter interactions. However, this claim remains controversial, as several experiments have tested the modulation signal using NaI(Tl) detectors. Among them, the COSINE-100 experiment, specifically designed to test DAMA/LIBRA's claim, observed no significant signal, revealing a more than 3 $σ$ discrepancy with DAMA/LIBRA's results. Here we present COSINE-100U, an upgraded version of the experiment, which aims to expand the search for dark matter interactions by improving light collection efficiency and reducing background noise. The detector, consisting of eight NaI(Tl) crystals with a total mass of 99.1 kg, has been relocated to Yemilab, a new underground facility in Korea, and features direct PMT-coupling technology to enhance sensitivity. These upgrades significantly improve the experiment's ability to probe low-mass dark matter candidates, contributing to the ongoing global effort to clarify the nature of dark matter.

hep-ex↗

Improved limit on neutrinoless double beta decay of $^{100}$Mo from AMoRE-I

AMoRE searches for the signature of neutrinoless double beta decay of $^{100}$Mo with a 100 kg sample of enriched $^{100}$Mo. Scintillating molybdate crystals coupled with a metallic magnetic calorimeter operate at milli-Kelvin temperatures to measure the energy of electrons emitted in the decay. As a demonstration of the full-scale AMoRE, we conducted AMoRE-I, a pre-experiment with 18 molybdate crystals, at the Yangyang Underground Laboratory for over two years. The exposure was 8.02 kg$\cdot$year (or 3.89 kg$_{\mathrm{^{100}Mo}}\cdot$year) and the total background rate near the Q-value was 0.025 $\pm$ 0.002 counts/keV/kg/year. We observed no indication of $0νββ$ decay and report a new lower limit of the half-life of $^{100}$Mo $0νββ$ decay as $ T^{0ν}_{1/2}>2.9\times10^{24}~\mathrm{yr}$ at 90\% confidence level. The effective Majorana mass limit range is $m_{ββ}<$(210--610) meV using nuclear matrix elements estimated in the framework of different models, including the recent shell model calculations.

nucl-ex↗

Development of MMC-based lithium molybdate cryogenic calorimeters for AMoRE-II

The AMoRE collaboration searches for neutrinoless double beta decay of $^{100}$Mo using molybdate scintillating crystals via low temperature thermal calorimetric detection. The early phases of the experiment, AMoRE-pilot and AMoRE-I, have demonstrated competitive discovery potential. Presently, the AMoRE-II experiment, featuring a large detector array with about 90 kg of $^{100}$Mo isotope, is under construction. This paper discusses the baseline design and characterization of the lithium molybdate cryogenic calorimeters to be used in the AMoRE-II detector modules. The results from prototype setups that incorporate new housing structures and two different crystal masses (316 g and 517 - 521 g), operated at 10 mK temperature, show energy resolutions (FWHM) of 7.55 - 8.82 keV at the 2.615 MeV $^{208}$Tl $γ$ line, and effective light detection of 0.79 - 0.96 keV/MeV. The simultaneous heat and light detection enables clear separation of alpha particles with a discrimination power of 12.37 - 19.50 at the energy region around $^6$Li(n, $α$)$^3$H with Q-value = 4.785 MeV. Promising detector performances were demonstrated at temperatures as high as 30 mK, which relaxes the temperature constraints for operating the large AMoRE-II array.

physics.ins-det↗

First Direct Search for Light Dark Matter Using the NEON Experiment at a Nuclear Reactor

We report new results from the Neutrino Elastic Scattering Observation with NaI (NEON) experiment in the search for light dark matter (LDM) using 2,636 kg$\cdot$days of NaI(Tl) exposure. The experiment employs an array of NaI(Tl) crystals with a total mass of 16.7 kg, located 23.7 meters away from a 2.8 GW thermal power nuclear reactor. We investigated LDM produced by the $\textit{invisible decay}$ of dark photons generated by high-flux photons during reactor operation. The energy spectra collected during reactor-on and reactor-off periods were compared within the LDM signal region of $1-10$ keV. No signal consistent with LDM interaction with electrons was observed, allowing us to set 90% confidence level exclusion limits for the dark matter-electron scattering cross-section ($σ_e$) across dark matter masses ranging from 1 keV/c$^2$ to 1 MeV/c$^2$. Our results set a 90% confidence level upper limit of $σ_e = 3.17\times10^{-35}~\mathrm{cm^2}$ for a dark matter mass of 100 keV/c$^2$, marking the best laboratory result in this mass range. Additionally, our search extends the coverage of LDM below 100 keV/c$^2$ first time.

hep-ex↗

Lowering threshold of NaI(Tl) scintillator to 0.7 keV in the COSINE-100 experiment

COSINE-100 is a direct dark matter search experiment, with the primary goal of testing the annual modulation signal observed by DAMA/LIBRA, using the same target material, NaI(Tl). In previous analyses, we achieved the same 1 keV energy threshold used in the DAMA/LIBRA's analysis that reported an annual modulation signal with 11.6$σ$ significance. In this article, we report an improved analysis that lowered the threshold to 0.7 keV, thanks to the application of Multi-Layer Perception network and a new likelihood parameter with waveforms in the frequency domain. The lower threshold would enable a better comparison of COSINE-100 with new DAMA results with a 0.75 keV threshold and account for differences in quenching factors. Furthermore the lower threshold can enhance COSINE-100's sensitivity to sub-GeV dark matter searches.

hep-ex↗

Two-neutrino double electron capture of $^{124}$Xe in the first LUX-ZEPLIN exposure

The broad physics reach of the LUX-ZEPLIN (LZ) experiment covers rare phenomena beyond the direct detection of dark matter. We report precise measurements of the extremely rare decay of $^{124}$Xe through the process of two-neutrino double electron capture (2$ν$2EC), utilizing a $1.39\,\mathrm{kg} \times \mathrm{yr}$ isotopic exposure from the first LZ science run. A half-life of $T_{1/2}^{2\nu2\mathrm{EC}} = (1.09 \pm 0.14_{\text{stat}} \pm 0.05_{\text{sys}}) \times 10^{22}\,\mathrm{yr}$ is observed with a statistical significance of $8.3\,σ$, in agreement with literature. First empirical measurements of the KK capture fraction relative to other K-shell modes were conducted, and demonstrate consistency with respect to recent signal models at the $1.4\,σ$ level.

nucl-ex↗

Projected background and sensitivity of AMoRE-II

AMoRE-II aims to search for neutrinoless double beta decay with an array of 423 Li$_2$$^{100}$MoO$_4$ crystals operating in the cryogenic system as the main phase of the Advanced Molybdenum-based Rare process Experiment (AMoRE). AMoRE has been planned to operate in three phases: AMoRE-pilot, AMoRE-I, and AMoRE-II. AMoRE-II is currently being installed at the Yemi Underground Laboratory, located approximately 1000 meters deep in Jeongseon, Korea. The goal of AMoRE-II is to reach up to $T^{0νββ}_{1/2}$ $\sim$ 6 $\times$ 10$^{26}$ years, corresponding to an effective Majorana mass of 15 - 29 meV, covering all the inverted mass hierarchy regions. To achieve this, the background level of the experimental configurations and possible background sources of gamma and beta events should be well understood. We have intensively performed Monte Carlo simulations using the GEANT4 toolkit in all the experimental configurations with potential sources. We report the estimated background level that meets the 10$^{-4}$counts/(keV$\cdot$kg$\cdot$yr) requirement for AMoRE-II in the region of interest (ROI) and show the projected half-life sensitivity based on the simulation study.

physics.ins-det↗

The Design, Implementation, and Performance of the LZ Calibration Systems

LUX-ZEPLIN (LZ) is a tonne-scale experiment searching for direct dark matter interactions and other rare events. It is located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. The core of the LZ detector is a dual-phase xenon time projection chamber (TPC), designed with the primary goal of detecting Weakly Interacting Massive Particles (WIMPs) via their induced low energy nuclear recoils. Surrounding the TPC, two veto detectors immersed in an ultra-pure water tank enable reducing background events to enhance the discovery potential. Intricate calibration systems are purposely designed to precisely understand the responses of these three detector volumes to various types of particle interactions and to demonstrate LZ's ability to discriminate between signals and backgrounds. In this paper, we present a comprehensive discussion of the key features, requirements, and performance of the LZ calibration systems, which play a crucial role in enabling LZ's WIMP-search and its broad science program. The thorough description of these calibration systems, with an emphasis on their novel aspects, is valuable for future calibration efforts in direct dark matter and other rare-event search experiments.

physics.ins-det↗

Improved background modeling for dark matter search with COSINE-100

COSINE-100 aims to conclusively test the claimed dark matter annual modulation signal detected by DAMA/LIBRA collaboration. DAMA/LIBRA has released updated analysis results by lowering the energy threshold to 0.75 keV through various upgrades. They have consistently claimed to have observed the annual modulation. In COSINE-100, it is crucial to lower the energy threshold for a direct comparison with DAMA/LIBRA, which also enhances the sensitivity of the search for low-mass dark matter, enabling COSINE-100 to explore this area. Therefore, it is essential to have a precise and quantitative understanding of the background spectrum across all energy ranges. This study expands the background modeling from 0.7 to 4000 keV using 2.82 years of COSINE-100 data. The modeling has been improved to describe the background spectrum across all energy ranges accurately. Assessments of the background spectrum are presented, considering the nonproportionality of NaI(Tl) crystals at both low and high energies and the characteristic X-rays produced by the interaction of external backgrounds with materials such as copper. Additionally, constraints on the fit parameters obtained from the alpha spectrum modeling fit are integrated into this model. These improvements are detailed in the paper.

astro-ph.IM↗

The Data Acquisition System of the LZ Dark Matter Detector: FADR

The Data Acquisition System (DAQ) for the LUX-ZEPLIN (LZ) dark matter detector is described. The signals from 745 PMTs, distributed across three subsystems, are sampled with 100-MHz 32-channel digitizers (DDC-32s). A basic waveform analysis is carried out on the on-board Field Programmable Gate Arrays (FPGAs) to extract information about the observed scintillation and electroluminescence signals. This information is used to determine if the digitized waveforms should be preserved for offline analysis. The system is designed around the Kintex-7 FPGA. In addition to digitizing the PMT signals and providing basic event selection in real time, the flexibility provided by the use of FPGAs allows us to monitor the performance of the detector and the DAQ in parallel to normal data acquisition. The hardware and software/firmware of this FPGA-based Architecture for Data acquisition and Realtime monitoring (FADR) are discussed and performance measurements are described.

physics.ins-det↗

Measurements of low-energy nuclear recoil quenching factors for Na and I recoils in the NaI(Tl) scintillator

Elastic scattering off nuclei in target detectors, involving interactions with dark matter and coherent elastic neutrino nuclear recoil (CE$ν$NS), results in the deposition of low energy within the nuclei, dissipating rapidly through a combination of heat and ionization. The primary energy loss mechanism for nuclear recoil is heat, leading to consistently smaller measurable scintillation signals compared to electron recoils of the same energy. The nuclear recoil quenching factor (QF), representing the ratio of scintillation light yield produced by nuclear recoil to that of electron recoil at the same energy, is a critical parameter for understanding dark matter and neutrino interactions with nuclei. The low energy QF of NaI(Tl) crystals, commonly employed in dark matter searches and CE$ν$NS measurements, is of substantial importance. Previous low energy QF measurements were constrained by contamination from photomultiplier tube (PMT)-induced noise, resulting in an observed light yield of approximately 15 photoelectrons per keVee (kilo-electron-volt electron-equivalent energy) and nuclear recoil energy above 5 keVnr (kilo-electron-volt nuclear recoil energy). Through enhanced crystal encapsulation, an increased light yield of around 26 photoelectrons per keVee is achieved. This improvement enables the measurement of the nuclear recoil QF for sodium nuclei at an energy of 3.8 $\pm$ 0.6 keVnr with a QF of 11.2 $\pm$ 1.7%. Furthermore, a reevaluation of previously reported QF results is conducted, incorporating enhancements in low energy events based on waveform simulation. The outcomes are generally consistent with various recent QF measurements for sodium and iodine.

hep-ex↗

Upgrade of NaI(Tl) crystal encapsulation for the NEON experiment

The Neutrino Elastic-scattering Observation with NaI(Tl) experiment (NEON) aims to detect coherent elastic neutrino-nucleus scattering~(\cenns) in a NaI(Tl) crystal using reactor anti-electron neutrinos at the Hanbit nuclear power plant complex. A total of 13.3 kg of NaI(Tl) crystals were initially installed in December 2020 at the tendon gallery, 23.7$\pm$0.3\,m away from the reactor core, which operates at a thermal power of 2.8\,GW. Initial engineering operation was performed from May 2021 to March 2022 and observed unexpected photomultiplier-induced noise and a decreased light yield that were caused by leakage of liquid scintillator into the detector due to weakness of detector encapsulation. We upgraded the detector encapsulation design to prevent the leakage of the liquid scintillator. Meanwhile two small-sized detectors were replaced with larger ones resulting in a total mass of 16.7\,kg. With this new design implementation, the detector system has been operating stably since April 2022 for over a year without detector gain drop. In this paper, we present an improved crystal encapsulation design and stability of the NEON experiment.

physics.ins-det↗

Waveform Simulation for Scintillation Characteristics of NaI(Tl) Crystal

The lowering of the energy threshold in the NaI detector is crucial not only for comprehensive validation of DAMA/LIBRA but also for exploring new possibilities in the search for low-mass dark matter and observing coherent elastic scattering between neutrino and nucleus. Alongside hardware enhancements, extensive efforts have focused on refining event selection to discern noise, achieved through parameter development and the application of machine learning. Acquiring pure, unbiased datasets is crucial in this endeavor, for which a waveform simulation was developed. The simulation data were compared with the experimental data using several pulse shape discrimination parameters to test its performance in describing the experimental data. Additionally, we present the outcomes of multi-variable machine learning trained with simulation data as a scintillation signal sample. The distributions of outcomes for experimental and simulation data show a good agreement. As an application of the waveform simulation, we validate the trigger efficiency alongside estimations derived from the minimally biased measurement data.

physics.ins-det↗

Nonproportionality of NaI(Tl) Scintillation Detector for Dark Matter Search Experiments

We present a comprehensive study of the nonproportionality of NaI(Tl) scintillation detectors within the context of dark matter search experiments. Our investigation, which integrates COSINE-100 data with supplementary $γ$ spectroscopy, measures light yields across diverse energy levels from full-energy $γ$ peaks produced by the decays of various isotopes. These $γ$ peaks of interest were produced by decays supported by both long and short-lived isotopes. Analyzing peaks from decays supported only by short-lived isotopes presented a unique challenge due to their limited statistics and overlapping energies, which was overcome by long-term data collection and a time-dependent analysis. A key achievement is the direct measurement of the 0.87 keV light yield, resulting from the cascade following electron capture decay of $^{22}$Na from internal contamination. This measurement, previously accessible only indirectly, deepens our understanding of NaI(Tl) scintillator behavior in the region of interest for dark matter searches. This study holds substantial implications for background modeling and the interpretation of dark matter signals in NaI(Tl) experiments.

hep-ex↗