Searcharxiv⌕ Search

arXiv subjects

Y. Ito

Publications and source records attributed to Y. Ito.

At least 37 records · Page 2Linked to original sources

Sensitivity and discovery potential of the proposed nEXO experiment to neutrinoless double beta decay

The next-generation Enriched Xenon Observatory (nEXO) is a proposed experiment to search for neutrinoless double beta ($0νββ$) decay in $^{136}$Xe with a target half-life sensitivity of approximately $10^{28}$ years using $5\times10^3$ kg of isotopically enriched liquid-xenon in a time projection chamber. This improvement of two orders of magnitude in sensitivity over current limits is obtained by a significant increase of the $^{136}$Xe mass, the monolithic and homogeneous configuration of the active medium, and the multi-parameter measurements of the interactions enabled by the time projection chamber. The detector concept and anticipated performance are presented based upon demonstrated realizable background rates.

nucl-ex↗

nEXO Pre-Conceptual Design Report

The projected performance and detector configuration of nEXO are described in this pre-Conceptual Design Report (pCDR). nEXO is a tonne-scale neutrinoless double beta ($0νββ$) decay search in $^{136}$Xe, based on the ultra-low background liquid xenon technology validated by EXO-200. With $\simeq$ 5000 kg of xenon enriched to 90% in the isotope 136, nEXO has a projected half-life sensitivity of approximately $10^{28}$ years. This represents an improvement in sensitivity of about two orders of magnitude with respect to current results. Based on the experience gained from EXO-200 and the effectiveness of xenon purification techniques, we expect the background to be dominated by external sources of radiation. The sensitivity increase is, therefore, entirely derived from the increase of active mass in a monolithic and homogeneous detector, along with some technical advances perfected in the course of a dedicated R&D program. Hence the risk which is inherent to the construction of a large, ultra-low background detector is reduced, as the intrinsic radioactive contamination requirements are generally not beyond those demonstrated with the present generation $0νββ$ decay experiments. Indeed, most of the required materials have been already assayed or reasonable estimates of their properties are at hand. The details described herein represent the base design of the detector configuration as of early 2018. Where potential design improvements are possible, alternatives are discussed. This design for nEXO presents a compelling path towards a next generation search for $0νββ$, with a substantial possibility to discover physics beyond the Standard Model.

physics.ins-det↗

Study of Silicon Photomultiplier Performance in External Electric Fields

We report on the performance of silicon photomultiplier (SiPM) light sensors operating in electric field strength up to 30 kV/cm and at a temperature of 149K, relative to their performance in the absence of an external electric field. The SiPM devices used in this study show stable gain, photon detection efficiency, and rates of correlated pulses, when exposed to external fields, within the estimated uncertainties. No observable physical damage to the bulk or surface of the devices was caused by the exposure.

physics.ins-det↗

New mass anchor points for neutron-deficient heavy nuclei from direct mass measurements of radium and actinium isotopes

The masses of the exotic isotopes $^{210-214}$Ac and $^{210-214}$Ra have been measured with a multi-reflection time-of-flight mass spectrograph. These isotopes were obtained in flight as fusion-evaporation products behind the gas-filled recoil ion separator GARIS-II at RIKEN. The new direct mass measurements serve as an independent and direct benchmark for existing $α$-$γ$ spectroscopy data in this mass region. Further, new mass anchor points are set for U and Np nuclei close to the $N=126$ shell closure for a future benchmark of the $Z=92$ sub-shell for neutron-deficient heavy isotopes. Our mass results are in general in good agreement with the previously indirectly-determined mass values. Together with the measurement data, reasons for possible mass ambiguities from decay-data links between ground states are discussed.

nucl-ex↗

Improving wide-band mass measurements in a multi-reflection time-of-flight mass spectrograph by usage of a concomitant measurement scheme

We introduce a new concomitant referencing mode for operating a multi-reflection time-of-flight mass spectrograph (MRTOF-MS), wherein the reference and analyte ions are interleaved on a cycle by cycle bases. Using this mode, we demonstrate an improved technique for performing wide bandwidth mass measurements via MRTOF-MS. This new technique offers a simplified analysis and high-accuracy.

physics.ins-det↗

First direct mass measurements of nuclides around $Z=100$ with a Multireflection Time-of-Flight Mass Spectrograph

The masses of $^{246}$Es, $^{251}$Fm and the transfermium nuclei $^{249-252}$Md, and $^{254}$No, produced by hot- and cold-fusion reactions, in the vicinity of the deformed $N=152$ neutron shell closure, have been directly measured using a multireflection time-of-flight mass spectrograph. The masses of $^{246}$Es and $^{249,250,252}$Md were measured for the first time. Using the masses of $^{249,250}$Md as anchor points for $α$ decay chains, the masses of heavier nuclei, up to $^{261}$Bh and $^{266}$Mt, were determined. These new masses were compared with theoretical global mass models and demonstrated to be in good agreement with macroscopic-microscopic models in this region. The empirical shell gap parameter $δ_{2n}$ derived from three isotopic masses was updated with the new masses and corroborate the existence of the deformed $N=152$ neutron shell closure for Md and Lr.

nucl-ex↗

Atomic masses of intermediate-mass neutron-deficient nuclei with relative uncertainty down to 35-ppb via multireflection time-of-flight mass spectrograph

High-precision mass measurements of $^{63}$Cu, $^{64-66}$Zn, $^{65}$Ga, $^{65-67}$Ge, $^{67}$As, $^{78,81}$Br, $^{80}$Rb, and $^{79}$Sr were performed utilizing a multireflection time-of-flight mass spectrograph combined with the gas-filled recoil ion separator GARIS-II. In the case of $^{65}$Ga, a mass uncertainty of 2.1 keV, corresponding to a relative precision of $δm / m = 3.5\times10^{-8}$, was obtained and the mass value is in excellent agreement with the 2016 Atomic Mass Evaluation. For $^{67}$Ge and $^{81}$Br, where masses were previously deduced through indirect measurements, discrepancies with literature values were found. The feasibility of using this device for mass measurements of nuclides more neutron-deficient side, which have significant impact on the $rp$-process pathway, is discussed.

nucl-ex↗

Characterization of an Ionization Readout Tile for nEXO

A new design for the anode of a time projection chamber, consisting of a charge-detecting "tile", is investigated for use in large scale liquid xenon detectors. The tile is produced by depositing 60 orthogonal metal charge-collecting strips, 3~mm wide, on a 10~\si{\cm} $\times$ 10~\si{\cm} fused-silica wafer. These charge tiles may be employed by large detectors, such as the proposed tonne-scale nEXO experiment to search for neutrinoless double-beta decay. Modular by design, an array of tiles can cover a sizable area. The width of each strip is small compared to the size of the tile, so a Frisch grid is not required. A grid-less, tiled anode design is beneficial for an experiment such as nEXO, where a wire tensioning support structure and Frisch grid might contribute radioactive backgrounds and would have to be designed to accommodate cycling to cryogenic temperatures. The segmented anode also reduces some degeneracies in signal reconstruction that arise in large-area crossed-wire time projection chambers. A prototype tile was tested in a cell containing liquid xenon. Very good agreement is achieved between the measured ionization spectrum of a $^{207}$Bi source and simulations that include the microphysics of recombination in xenon and a detailed modeling of the electrostatic field of the detector. An energy resolution $σ/E$=5.5\% is observed at 570~\si{keV}, comparable to the best intrinsic ionization-only resolution reported in literature for liquid xenon at 936~V/\si{cm}.

physics.ins-det↗

Measurements of azimuthal anisotropy and charged-particle multiplicity in $d$$+$Au collisions at $\sqrt{s_{_{NN}}}=$200, 62.4, 39, and 19.6 GeV

We present measurements of the elliptic flow, $v_2$, as a function of transverse momentum ($p_T$), pseudorapidity ($η$), and centrality in $d$$+$Au collisions at $\sqrt{s_{_{NN}}}=$200, 62.4, 39, and 19.6 GeV. The beam-energy scan of $d$$+$Au collisions provides a testing ground for the onset of flow signatures in small collision systems. We measure a nonzero $v_2$ signal at all four collision energies, which, at midrapidity and low $p_T$, is consistent with predictions from viscous hydrodynamic models. Comparisons with calculations from parton transport models (based on the {\sc ampt} Monte Carlo generator) show good agreement with the data at midrapidity to forward ($d$-going) rapidities and low $p_T$. At backward (Au-going) rapidities and $p_T>1.5$ GeV/$c$, the data diverges from {\sc ampt} calculations of $v_2$ relative to the initial geometry, indicating the possible dominance of nongeometry related correlations, referred to as nonflow. We also present measurements of the charged-particle multiplicity ($dN_{\rm ch}/dη$) as a function of $η$ in central $d$$+$Au collisions at the same energies. We find that in $d$$+$Au collisions at $\sqrt{s_{_{NN}}}=$200 GeV the $v_2$ scales with $dN_{\rm ch}/dη$ over all $η$ in the PHENIX acceptance. At $\sqrt{s_{_{NN}}}=$62.4, and 39 GeV, $v_2$ scales with $dN_{\rm ch}/dη$ at midrapidity and forward rapidity, but falls off at backward rapidity. This departure from the $dN_{\rm ch}/dη$ scaling may be a further indication of nonflow effects dominating at backward rapidity.

nucl-ex↗

Proton-proton correlations in distinguishing the two-proton emission mechanism of $^{23}$Al and $^{22}$Mg

The proton-proton momentum correlation functions ($C_{pp}(q)$) for kinematically complete decay channels of $^{23}$Al $\rightarrow$ p + p + $^{21}$Na and $^{22}$Mg $\rightarrow$ p + p + $^{20}$Ne have been measured at the RIKEN RI Beam Factory. From the very different correlation strength of $C_{pp}(q)$ for $^{23}$Al and $^{22}$Mg, the source size and emission time information were extracted from the $C_{pp}(q)$ data by assuming a Gaussian source profile in the correlation function calculation code (CRAB). The results indicated that the mechanism of two-proton emission from $^{23}$Al was mainly sequential emission, while that of $^{22}$Mg was mainly three-body simultaneous emission. By combining our earlier results of the two-proton relative momentum and the opening angle, it is pointed out that the mechanism of two-proton emission could be distinguished clearly.

nucl-ex↗

First Online Mass Measurements of Isobar Chains via Multi-Reflection Time-of-Flight Mass Spectrograph Coupled with GARIS-II

Using a mulit-reflection time-of-flight mass spectrograph (MRTOF-MS) located after a gas cell coupled with the gas-filled recoil ion separator GARIS-II, the masses of several heavy nuclei have been directly and precisely measured. The nuclei were produced via fusion-evaporation reactions and separated from projectile-like and target-like particles using GARIS-II before being stopped in a helium-filled gas cell. Time-of-flight spectra for three isobar chains, 205Fr-205Rn-205At-205Po, 206Fr-206Rn-206At and 201Rn-201At-201Po-201Bi, were observed. Precision atomic mass values were determined for 205,206Fr, 201At, and 201Po.

nucl-ex↗

Electric-field-induced superconductivity in electrochemically-etched ultrathin FeSe films on SrTiO3 and MgO

Among the recently discovered iron-based superconductors, ultrathin films of FeSe grown on SrTiO3 substrates have uniquely evolved into a high superconducting-transition-temperature (TC) material. The mechanisms for the high-TC superconductivity are ongoing debate mainly with the superconducting gap characterized with in-situ analysis for FeSe films grown by bottom-up molecular-beam epitaxy. Here, we demonstrate the alternative access to investigate the high-TC superconductivity in ultrathin FeSe with top-down electrochemical etching technique in three-terminal transistor configuration. In addition to the high-TC FeSe on SrTiO3, the electrochemically etched ultrathin FeSe transistor on MgO also exhibits superconductivity around 40 K, implying that the application of electric-field effectively contributes to the high-TC superconductivity in ultrathin FeSe regardless of substrate material. Moreover, the observable critical thickness for the high-TC superconductivity is expanded up to 10-unit-cells under applying electric-field and the insulator-superconductor transition is electrostatically controlled. The present demonstration implies that the electric-field effect on both conduction and valence bands plays a crucial role for inducing high-TC superconductivity in FeSe.

cond-mat.supr-con↗

Different mechanism of two-proton emission from proton-rich nuclei $^{23}$Al and $^{22}$Mg

Two-proton relative momentum ($q_{pp}$) and opening angle ($θ_{pp}$) distributions from the three-body decay of two excited proton-rich nuclei, namely $^{23}$Al $\rightarrow$ p + p + $^{21}$Na and $^{22}$Mg $\rightarrow$ p + p + $^{20}$Ne, have been measured with the projectile fragment separator (RIPS) at the RIKEN RI Beam Factory. An evident peak at $q_{pp}\sim20$ MeV/c as well as a peak in $θ_{pp}$ around 30$^\circ$ are seen in the two-proton break-up channel from a highly-excited $^{22}$Mg. In contrast, such peaks are absent for the $^{23}$Al case. It is concluded that the two-proton emission mechanism of excited $^{22}$Mg is quite different from the $^{23}$Al case, with the former having a favorable diproton emission component at a highly excited state and the latter dominated by the sequential decay process.

nucl-ex↗

A Method of Evaluating Effect of QoS Degradation on Multidimensional QoE of Web Service with ISO - based Usability

This paper studies a method of investigating effect of IP performance (QoS) degradation on quality of experience (QoE) for a Web service; it considers the usability based on the ISO 9241-11 as multidimensional QoE of a Web service (QoE-Web) and the QoS parameters standardized by the IETF. Moreover, the paper tackles clarification of the relationship between ISO-based QoE-Web and IETF-based QoS by the multiple regression analysis. The experiment is intended for the two actual Japanese online shopping services and utilizes 35 subjects. From the results, the paper quantitatively discusses how the QoE-Web deteriorates owing to the QoS degradation and shows that it is appropriate to evaluate the proposed method.

cs.NI↗

A novel ion cooling trap for multi-reflection time-of-flight mass spectrograph

A radiofrequency quadrupole ion trap system for use with a multi-reflection time-of-flight mass spectrograph (MRTOF) for short-lived nuclei has been developed. The trap system consists of two different parts, an asymmetric taper trap and a flat trap. The ions are cooled to a sufficient small bunch for precise mass measurement with MRTOF in only 2 ms cooling time in the flat trap, then orthogonally ejected to the MRTOF for mass analysis. A trapping efficiency of ~27% for 23Na+ and ~5.1% for 7Li+ has been achieved.

physics.ins-det↗

Single-reference high-precision mass measurement with a multi-reflection time-of-flight mass spectrograph

A multi-reflection time-of-flight mass spectrograph, competitive with Penning trap mass spectrometers, has been built at RIKEN. We have performed a first online mass measurement, using 8Li+ (T1/2 = 838 ms). A new analysis method has been realized, with which, using only 12C+ references, the mass excess of 8Li was accurately determined to be 20947.6(15)(34) keV (dm/m = 6.6 x 10-7). The speed, precision and accuracy of this first online measurement exemplifies the potential for using this new type of mass spectrograph for precision measurements of short-lived nuclei.

nucl-ex↗

An rf-carpet electrospray ion source to provide isobaric mass calibrants for trans-uranium elements

For trans-uranium elements, stable atomic isobars do not exist. In order to provide isobaric reference ions for the mass measurement of trans-uranium elements, an electrospray ion source (ESI) was combined with an rf-carpet to collect molecular ions efficiently. The rf-carpet allows for simplification of the pumping system to transport ions from the ESI to a precision mass analyzer. Molecular ions appropriate for isobaric references of trans-uranium elements were extracted from the rf-carpet and analyzed by a multi-reflection time-of-flight mass spectrograph (MRTOF-MS) with a resolving power of $\rm{R_m} \gtrsim100,000$.

nucl-ex↗