SearcharxivSearch

arXiv subjects

Y. Ito

Publications and source records attributed to Y. Ito.

At least 19 recordsLinked to original sources

High-Precision Mass Measurements of Proton-Rich Rh, Pd, Cd isotopes in the vicinity of 100Sn and Impact on X-Ray Burst and Supernova Nucleosynthesis

Using the ZeroDegree multi-reflection time-of-flight mass spectrograph of the CRISMASS project at RIKEN Radioactive Isotope Beam Factory, we performed high-precision mass measurements of proton-rich nuclei near the doubly magic nucleus 100Sn, achieving uncertainties on the order of 10 keV. The masses of 91Rh, 92Pd, and 96Cd were determined for the first time with high precision, and the accuracy of several additional masses was substantially improved. Incorporating the new data into X-ray burst simulations significantly reduces the abundance uncertainties in the $A$ = 90-100 region, shifting the reaction flow toward $A$ = 90 production and suppressing the synthesis of heavier nuclei. Further investigation of the $\nu p$-process indicates that 99Rh plays a significant role in the reaction flow within the mass region studied. These high-precision mass measurements refine the mass surface near 100Sn and provide critical constraints on models of proton-rich nucleosynthesis.

nucl-ex

New Ground State in ${}^{149}$La Removes Two-Neutron-Separation-Energy Anomaly in Lanthanum Isotopes

Nuclear mass is a key indicator of how the nuclear shell structure evolves. The recent mass measurement study of neutron-rich lanthanum isotopes [A. Jaries, $et~al$., Phys. Rev. Lett. {\bf 134}, 042501(2025)] reveals the presence of a distinct prominence in their two-neutron separation energies. However, its presence has been called into question based on the results of another mass determination [B. Liu, Ph.D. thesis, University of Notre Dame (2025)]. In this letter, we report an effort to clarify these contradictory results through the use of the simultaneous mass-lifetime measurement of the neutron-rich lanthanum isotope ${}^{149}$La using a multi-reflection time-of-flight mass spectrograph combined with a $\beta$-TOF detector. The peak corresponding to a $\beta$-decaying state was observed in the time-of-flight spectra at a position of $221(6)~{\rm keV/c^2}$ lighter than the reported ${}^{149}$La mass in A. Jaries, $et~al$., but our measured result is in excellent agreement with the mass value reported in B. Liu. We have concluded that this peak is the ground state of ${}^{149}$La. With this, the previously reported distinct prominence in the two-neutron separation energies disappears, while a new kink structure, similar to that in the cerium isotopes, appears. Comparison with theoretical models suggests that a nuclear shape transition from octupole deformation to another type of deformation occurs around $N=91$ and is likely the cause of this kink structure.

nucl-ex

The Imaging Time-of-Propagation Detector at Belle II

We report on the construction, operation, and performance of the Time-of-Propagation detector with imaging used for the Belle II experiment running at the Super-KEKB $e^+e^-$ collider. This detector is located in the central barrel region and uses Cherenkov light to provide particle identification among hadrons. The Cherenkov light is radiated in highly polished bars of synthetic fused silica (quartz) and transported to the ends of the bars via total internal reflection. One bar end is instrumented with finely segmented micro-channel-plate photomultiplier tubes to record the light, while the other end has a mirror attached to reflect the photons back to the instrumented end. Both the propagation times and hit positions of the Cherenkov photons are measured; these depend on the Cherenkov angle and together provide good discrimination among charged pions, kaons, and protons with momenta up to around 4 GeV/$c$. To date, the detector has been used to record and analyze almost 600 fb$^{-1}$ of Belle II data.

hep-ex

Precision mass measurements around ${}^{84}$Mo rule out ZrNb cycle formation in the rapid proton-capture process at type I X-ray bursts

The rapid proton-capture ($rp$-) process is one of the primary, explosive thermonuclear burning processes that drive type I X-ray bursts. A possible termination of the $rp$-process at around ${}^{84}$Mo was previously suggested by the formation of a ZrNb cycle. We report here precision mass measurements at around ${}^{84}$Mo, which have concluded the possibility of the cycle. The experiment was conducted using the multi-reflection time-of-flight spectrograph at RIKEN RI Beam Factory, and the masses of ${}^{79}$Y, ${}^{83}$Nb, ${}^{84}$Mo, ${}^{88}$Ru, and an isomer in ${}^{78}$Y were measured. For ${}^{84}$Mo, and ${}^{88}$Ru, and the isomeric state of ${}^{78}$Y, their masses are experimentally determined for the first time with uncertainties of $\delta m \approx 20~{\rm keV/c^2}$. The mass precision of ${}^{79}$Y and ${}^{83}$Nb is improved to $13~{\rm keV/c^2}$ and $9.6~{\rm keV/c^2}$, respectively. The new $\alpha$-separation energy of ${}^{84}$Mo, 1.434(83) MeV, unambiguously rules out the possibility of forming the ZrNb cycle. The X-ray burst simulation with the new masses shows that our measurements effectively remove the large final abundance uncertainties in the $A=80-90$ mass region. The new mass values improve the prediction power for the composition of the nuclear ashes in X-ray bursts.

nucl-ex

Disentangling centrality bias and final-state effects in the production of high-$p_T$ $\pi^0$ using direct $\gamma$ in $d$$+$Au collisions at $\sqrt{s_{_{NN}}}=200$ GeV

PHENIX presents a simultaneous measurement of the production of direct $\gamma$ and $\pi^0$ in $d$$+$Au collisions at $\sqrt{s_{_{NN}}}=200$ GeV over a $p_T$ range of 7.5 to 18 GeV/$c$ for different event samples selected by event activity, i.e. charged-particle multiplicity detected at forward rapidity. Direct-photon yields are used to empirically estimate the contribution of hard-scattering processes in the different event samples. Using this estimate, the average nuclear-modification factor $R_{d\rm Au,EXP}^{\gamma^{\rm dir}}$ is $0.925{\pm}0.023({\rm stat}){\pm}0.15^{\rm (scale)}$, consistent with unity for minimum-bias (MB) $d$$+$Au events. For event classes with moderate event activity, $R_{d\rm Au,EXP}^{\gamma^{\rm dir}}$ is consistent with the MB value within 5\% uncertainty. These results confirm that the previously observed enhancement of high-$p_T$ $\pi^0$ production found in small-system collisions with low event activity is a result of a bias in interpreting event activity within the Glauber framework. In contrast, for the top 5\% of events with the highest event activity, $R_{d\rm Au,EXP}^{\gamma^{\rm dir}}$ is suppressed by 20\% relative to the MB value with a significance of $4.5\sigma$, which may be due to final-state effects.

nucl-ex

A new study of the $N=32$ and $N=34$ shell gap for Ti and V by the first high-precision MRTOF mass measurements at BigRIPS-SLOWRI

The atomic masses of $^{55}$Sc, $^{56,58}$Ti, and $^{56-59}$V have been determined using the high-precision multi-reflection time-of-flight technique. The radioisotopes have been produced at RIKEN's RIBF facility and delivered to the novel designed gas cell and multi-reflection system (ZD MRTOF), which has been recently commissioned downstream of the ZeroDegree spectrometer following the BigRIPS separator. For $^{56,58}$Ti and $^{56-59}$V the mass uncertainties have been reduced down to the order of $10\,\mathrm{keV}$, shedding new light on the $N=34$ shell effect in Ti and V isotopes by the first high-precision mass measurements of the critical species $^{58}$Ti and $^{59}$V. With the new precision achieved, we reveal the non-existence of the $N=34$ empirical two-neutron shell gaps for Ti and V, and the enhanced energy gap above the occupied $νp_{3/2}$ orbit is identified as a feature unique to Ca. We perform new Monte Carlo shell model calculations including the $νd_{5/2}$ and $νg_{9/2}$ orbits and compare the results with conventional shell model calculations, which exclude the $νg_{9/2}$ and the $νd_{5/2}$ orbits. The comparison indicates that the shell gap reduction in Ti is related to a partial occupation of the higher orbitals for the outer two valence neutrons at $N=34$.

nucl-ex

The new MRTOF mass spectrograph following the ZeroDegree spectrometer at RIKEN's RIBF facility

A newly assembled multi-reflection time-of-flight mass spectrograph (MRTOF-MS) at RIKEN's RIBF facility became operational for the first time in spring 2020; further modifications and performance tests using stable ions were completed in early 2021. By using a pulsed-drift-tube technique to modify the ions' kinetic energy in a wide range, we directly characterize the dispersion function of the system for use in a new procedure for optimizing the voltages applied to the electrostatic mirrors. Thus far, a mass resolving power of $R_m > 1\,000\,000$ is reached within a total time-of-flight of only $12.5\,\mathrm{ms}$, making the spectrometer capable of studying short-lived nuclei possessing low-lying isomers. Detailed information about the setup and measurement procedure is reported, and an alternative in-MRTOF ion selection scheme to remove molecular contaminants in the absence of a dedicated deflection device is introduced. The setup underwent an initial on-line commissioning at the BigRIPS facility at the end of 2020, where more than 70 nuclear masses have been measured. A summary of the commissioning experiments and results from a test of mass accuracy will be presented.

physics.ins-det

The Exosphere as a Boundary: Origin and Evolution of Airless Bodies in the Inner Solar System and Beyond Including Planets with Silicate Atmospheres

In this review we discuss all the relevant solar/stellar radiation and plasma parameters and processes that act together in the formation and modification of atmospheres and exospheres that consist of surface-related minerals. Magma ocean degassed silicate atmospheres or thin gaseous envelopes from planetary building blocks, airless bodies in the inner Solar System, and close-in magmatic rocky exoplanets such as CoRot-7b, HD219134b and 55 Cnc e are addressed. The depletion and fractionation of elements from planetary embryos, which act as the building blocks for protoplanets are also discussed. In this context the formation processes of the Moon and Mercury are briefly reviewed. The Lunar surface modification since its origin by micrometeoroids, plasma sputtering, plasma impingement as well as chemical surface alteration and the search of particles from the early Earth's atmosphere that were collected by the Moon on its surface are also discussed. Finally, we address important questions on what can be learned from the study of Mercury's environment and its solar wind interaction by MESSENGER and BepiColombo in comparison with the expected observations at exo-Mercurys by future space-observatories such as the JWST or ARIEL and ground-based telescopes and instruments like SPHERE and ESPRESSO on the VLT, and vice versa.

astro-ph.EP

Characterization of a Spatially Resolved Multi-Element Laser Ablation Ion Source

A laser ablation ion source (LAS) is a powerful tool by which diverse species of ions can be produced for mass spectrometer calibration, or surface study applications. It is necessary to frequently shift the laser position on the target to selectively ablate materials in a controlled manner, and to mitigate degradation of the target surface caused by ablation. An alternative to mounting the target onto a rotation wheel or $x-y$ translation stage, is to shift the laser position with a final reflection from a motorized kinematic mirror mount. Such a system has been developed, assembled and characterized with a two axis motorized mirror and various metal targets. In the system presented here, ions are ablated from the target surface and guided by a 90 degree quadrupole bender to a Faraday cup where the ion current is measured. Spatially resolved scans of the target are produced by actuating the mirror motors, thus moving the laser spot across the target, and performing synchronous measurements of the ion current to construct 2D images of a target surface which can be up to 50~mm in diameter. The spatial resolution of the system has been measured by scanning the interfaces between metals such as steel and niobium, where it was demonstrated that the LAS can selectively ablate an area of diameter $\approx$50 $μ$m. This work informs the development of subsequent LAS systems, that are intended to serve as multi-element ion sources for commercial and custom-built time-of-flight mass spectrometers, or to selectively study surface specific regions of samples.

physics.ins-det

Alpha-decay-correlated mass measurement of 206,207Ra using an $α$-TOF detector equipped MRTOF-MS system

The atomic masses of the isotopes $^{206,207}$Ra have been measured via decay-correlated mass spectroscopy using a multi-reflection time-of-flight mass spectrograph equipped with an $α$-TOF detector. The Ra isotopes were produced as fusion-evaporation products in the $^{51}$V+$^{159}$Tb reaction system and delivered by the gas-filled recoil ion separator GARIS-II at RIKEN. The $α$-TOF detector provides for high-accuracy mass measurements by correlating time-of-flight signals with subsequent $α$-decay events. The masses of $^{206}$Ra and $^{207g,m}$Ra were directly measured using a multi-reflection time-of-flight mass spectrograph equipped with an $α$-TOF detector. A mass excess of ME = 3538(15) keV/c$^2$ and an excitation energy of E$_{\rm ex}$ = 552(42) keV were determined. The $α$-decay branching ratio of $^{207m}$Ra, b$α$ = 0.26(20), was directly determined from decay-correlated time-of-flight signals, and the reduced alpha width of $^{207m}$Ra was calculated to be $δ^2$ = 50+62-41 keV from the branching ratio. The spin-parity of $^{207m}$Ra was confirmed to be $J^π$ = 13/2$^-$ from decay correlated mass measurement results.

nucl-ex

The $^{59}$Fe(n, γ)$^{60}$Fe Cross Section from the Surrogate Ratio Method and Its Effect on the $^{60}$Fe Nucleosynthesis

The long-lived $^{60}$Fe (with a half-life of 2.62 Myr) is a crucial diagnostic of active nucleosynthesis in the Milky Way galaxy and in supernovae near the solar system. The neutron-capture reaction $^{59}$Fe(n,$γ$)$^{60}$Fe on $^{59}$Fe (half-life = 44.5 days) is the key reaction for the production of $^{60}$Fe in massive stars. This reaction cross section has been previously constrained by the Coulomb dissociation experiment, which offered partial constraint on the $E$1 $γ$-ray strength function but a negligible constraint on the $M$1 and $E$2 components. In this work, for the first time, we use the surrogate ratio method to experimentally determine the $^{59}$Fe(n,$γ$)$^{60}$Fe cross sections in which all the components are included. We derived a Maxwellian-averaged cross section of 27.5 $\pm$ 3.5 mb at $kT$= 30 keV and 13.4 $\pm$ 1.7 mb at $kT$= 90 keV, roughly 10 - 20% higher than previous estimates. We analyzed the impact of our new reaction rates in nucleosynthesis models of massive stars and found that uncertainties in the production of $^{60}$Fe from the $^{59}$Fe(n,$γ$)$^{60}$Fe rate are at most of 25%. We conclude that stellar physics uncertainties now play a major role in the accurate evaluation of the stellar production of $^{60}$Fe.

astro-ph.GA

First high-precision direct determination of the atomic mass of a superheavy nuclide

We present the first direct measurement of the atomic mass of a superheavy nuclide. Atoms of $^{257}$Db ($Z$=105) were produced online at the RIKEN Nishina Center for Accelerator-Based Science using the fusion-evaporation reaction $^{208}$Pb($^{51}$V, 2n)$^{257}$Db. The gas-filled recoil ion separator GARIS-II was used to suppress both the unreacted primary beam and some transfer products, prior to delivering the energetic beam of $^{257}$Db ions to a helium gas-filled ion stopping cell wherein they were thermalized. Thermalized $^{257}$Db$^{3+}$ ions were then transferred to a multi-reflection time-of-flight mass spectrograph for mass analysis. An alpha particle detector embedded in the ion time-of-flight detector allowed disambiguation of the rare $^{257}$Db$^{3+}$ time-of-flight detection events from background by means of correlation with characteristic $α$-decays. The extreme sensitivity of this technique allowed a precision atomic mass determination from 11 events. The mass excess was determined to be $100\,063(231)_\textrm{stat}(132)_\textrm{sys}$~keV/c$^2$. Comparing to several mass models, we show the technique can be used to unambiguously determine the atomic number as $Z$=105 and should allow similar evaluations for heavier species in future work.

nucl-ex

Accurately accounting for effects on times-of-flight caused by finite field-transition times during the ejection of ions from a storage trap: A study for TOF and MRTOF mass spectrometry

In applied forms of time-of-flight mass spectrometry utilizing ion storage devices prior to an analysis device, a non instantaneous electric ejection pulse applied in the region of ion storage is used to accelerate ions into the time-of-flight analyzer. The calculated mass value of the ions from the time-of-flight is dependent on the duration of the field transition up to full strength. For novel applications dedicated to precision measurements, such as multi-reflection time-of-flight mass spectrometry of short-lived isotopes, the goal is to continuously decrease the measurement uncertainty while providing a mass accuracy on the same order. Even though dynamic-field models for time-of-flight mass spectrometry have been considered in the past for technological advances, it is important to study the accuracy of the measured mass in this context. Using a simplified linear model for the field transition, we provide a basic investigation of the scenario, and discuss the deviation from the classical "mass-over-charge" dependency of the ions' time-of-flight, which becomes violated. The emerging mass discrepancy depends on the distance between the mass of the ion used for calibration and that of the ion of interest and, in extreme cases, can increase to about one percent for systems with short times-of-flight. However, for typical conditions in single-reference multi-reflection time-of-flight mass spectrometry, mass deviations caused by this effect typically remain below the 1 ppm level. If a mass calibration using two or more ion species is possible during the measurement, the effect becomes negligible for appropriate choices of reference masses.

physics.ins-det

Design of a Multiple-Reflection Time-of-Flight Mass-Spectrometer for Barium-tagging

The search for neutrinoless double beta decay requires increasingly advanced methods of background reduction. A bold approach to solving this problem, in experiments using Xe-136, is to extract and identify the daughter Ba-136 ion produced by double beta decay. Tagging events in this manner allows for a virtually background-free verification of double beta decay signals. Various approaches are being pursued by the nEXO collaboration to achieve Ba-tagging. A Multi-Reflection Time-of-Flight Mass Spectrometer (MR TOF) has been designed and optimized as one of the ion-identification methods, where it will investigate the ion-extraction efficiency, as well as provide further identification of the Ba isotope. The envisioned mode of operation allows the MR TOF to achieve a quickly adjustable mass-range and resolution, with simulations suggesting that a mass-resolving power of 140,000 is within reach. This work will discuss the MR TOF design and the methods employed to simulate and optimize it.

physics.ins-det

Characterization of the Hamamatsu VUV4 MPPCs for nEXO

In this paper we report on the characterization of the Hamamatsu VUV4 (S/N: S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Silicon Photo-Multipliers (SiPMs) as part of the development of a solution for the detection of liquid xenon scintillation light for the nEXO experiment. Various SiPM features, such as: dark noise, gain, correlated avalanches, direct crosstalk and Photon Detection Efficiency (PDE) were measured in a dedicated setup at TRIUMF. SiPMs were characterized in the range $163 \text{ } \text{K} \leq \text{T}\leq 233 \text{ } \text{K}$. At an over voltage of $3.1\pm0.2$ V and at $\text{T}=163 \text{ }\text{K}$ we report a number of Correlated Avalanches (CAs) per pulse in the $1 \upmu\text{s}$ interval following the trigger pulse of $0.161\pm0.005$. At the same settings the Dark-Noise (DN) rate is $0.137\pm0.002 \text{ Hz/mm}^{2}$. Both the number of CAs and the DN rate are within nEXO specifications. The PDE of the Hamamatsu VUV4 was measured for two different devices at $\text{T}=233 \text{ }\text{K}$ for a mean wavelength of $189\pm7\text{ nm}$. At $3.6\pm0.2$ V and $3.5\pm0.2$ V of over voltage we report a PDE of $13.4\pm2.6\text{ }\%$ and $11\pm2\%$, corresponding to a saturation PDE of $14.8\pm2.8\text{ }\%$ and $12.2\pm2.3\%$, respectively. Both values are well below the $24\text{ }\%$ saturation PDE advertised by Hamamatsu. More generally, the second device tested at $3.5\pm0.2$ V of over voltage is below the nEXO PDE requirement. The first one instead yields a PDE that is marginally close to meeting the nEXO specifications. This suggests that with modest improvements the Hamamatsu VUV4 MPPCs could be considered as an alternative to the FBK-LF SiPMs for the final design of the nEXO detector.

astro-ph.IM

Development of an "$α$-ToF" detector for correlated measurement of atomic masses and decay properties

We have developed a novel detector, referred to as an "$α$-ToF detector", for correlated measurements of atomic masses and decay properties of low-yield, short-lived radioactive isotopes using a multi-reflection time-of-flight mass spectrograph. By correlating measured time-of-flight signals with decay events, it will be possible to suppress background events and obtain accurate, high-precision mass values even in cases of very low event rates. An offline test of the $α$-ToF detector has shown that the time-of-flight detection efficiency for 5.48~MeV $α$-rays is more than 90\% and yields a time resolution of 251.5(68)~ps and an energy resolution of 141.1(9)~keV. Using a two-dimensional spectrum of the correlated $α$-ray energy and time-of-flight, the $α$-rays from mixed $α$ sources could be fairly well resolved.

physics.ins-det

VUV-sensitive Silicon Photomultipliers for Xenon Scintillation Light Detection in nEXO

Future tonne-scale liquefied noble gas detectors depend on efficient light detection in the VUV range. In the past years Silicon Photomultipliers (SiPMs) have emerged as a valid alternative to standard photomultiplier tubes or large area avalanche photodiodes. The next generation double beta decay experiment, nEXO, with a 5 tonne liquid xenon time projection chamber, will use SiPMs for detecting the $178\,\text{nm}$ xenon scintillation light, in order to achieve an energy resolution of $σ/ Q_{ββ} = 1\, \%$. This paper presents recent measurements of the VUV-HD generation SiPMs from Fondazione Bruno Kessler in two complementary setups. It includes measurements of the photon detection efficiency with gaseous xenon scintillation light in a vacuum setup and dark measurements in a dry nitrogen gas setup. We report improved photon detection efficiency at $175\,\text{nm}$ compared to previous generation devices, that would meet the criteria of nEXO. Furthermore, we present the projected nEXO detector light collection and energy resolution that could be achieved by using these SiPMs.

physics.ins-det

Imaging individual barium atoms in solid xenon for barium tagging in nEXO

The search for neutrinoless double beta decay probes the fundamental properties of neutrinos, including whether or not the neutrino and antineutrino are distinct. Double beta detectors are large and expensive, so background reduction is essential for extracting the highest sensitivity. The identification, or 'tagging', of the $^{136}$Ba daughter atom from double beta decay of $^{136}$Xe provides a technique for eliminating backgrounds in the nEXO neutrinoless double beta decay experiment. The tagging scheme studied in this work utilizes a cryogenic probe to trap the barium atom in solid xenon, where the barium atom is tagged via fluorescence imaging in the solid xenon matrix. Here we demonstrate imaging and counting of individual atoms of barium in solid xenon by scanning a focused laser across a solid xenon matrix deposited on a sapphire window. When the laser sits on an individual atom, the fluorescence persists for $\sim$30~s before dropping abruptly to the background level, a clear confirmation of one-atom imaging. No barium fluorescence persists following evaporation of a barium deposit to a limit of $\leq$0.16\%. This is the first time that single atoms have been imaged in solid noble element. It establishes the basic principle of a barium tagging technique for nEXO.

physics.ins-det