Searcharxiv⌕ Search

arXiv subjects

Y. Iwashita

Publications and source records attributed to Y. Iwashita.

At least 19 recordsLinked to original sources

Improved measurements of neutron lifetime with cold neutron beam at J-PARC

The ``neutron lifetime puzzle'' arises from the discrepancy between neutron lifetime measurements obtained using the beam method, which measures decay products, and the bottle method, which measures the disappearance of neutrons. To resolve this puzzle, we conducted an experiment using a pulsed cold neutron beam at J-PARC. In this experiment, the neutron lifetime is determined from the ratio of neutron decay counts to $^3$He(n,p)$^3$H reactions in a gas detector. This experiment belongs to the beam method but differs from previous experiments that measured protons, as it instead detects electrons, enabling measurements with distinct systematic uncertainties. By enlarging the beam transport system and reducing systematic uncertainties, we achieved a fivefold improvement in precision. Analysis of all acquired data yielded a neutron lifetime of $τ_{\rm n}=877.2~\pm~1.7_{\rm(stat.)}~^{+4.0}_{-3.6}{}_{\rm (sys.)}$ s. This result is consistent with bottle method measurements but exhibits a 2.3$σ$ tension with the average value obtained from the proton-detection-based beam method.

nucl-ex↗

The π^+π^- Coulomb interaction study and its use in the data processing

In this work the Coulomb effects (Coulomb correlations) in $π^+π^-$ pairs produced in p + Ni collisions at 24 GeV/$c$, are studied using experimental $π^+π^-$ pair distributions in $Q$, the relative momentum in the pair center of mass system (c.m.s), and its projections $Q_L$ (longitudinal component) and $Q_t$ (transverse component) relative to the pair direction in the laboratory system (l.s.). The $Q$, $Q_L$, and $Q_t$ distributions of the {\sl Coulomb pairs} in the c.m.s. have been simulated assuming they are described by the phase space modified by the known point-like Coulomb correlation function $A_C(Q)$, corrected for small effects due to the nonpoint-like pair production and the strong two-pion interaction. The same distributions of {\sl non-Coulomb pairs} have been simulated according to the phase space, but without $A_C(Q)$. It is shown that the number of {\sl Coulomb pairs} in all $Q_t$ intervals, including the small $Q_t$ (small opening angles $θ$ in the l.s.) is calculated with the theoretical precision better than 2\%. The comparison of the simulated and experimental numbers of {\sl Coulomb pairs} at small $Q_t$ allows us to check and correct the detection efficiency for the pairs with small $θ$ (0.06 mrad and smaller). It is shown that {\sl Coulomb pairs} can be used as a new physical tool to check and correct the quality of the simulated events. The special property of the {\sl Coulomb pairs} is the possibility of checking and correcting the detection efficiency, especially for the pairs with small opening angles.

hep-ph↗

Performance of the Fully-equipped Spin Flip Chopper For Neutron Lifetime Experiment at J-PARC

To solve the ''neutron lifetime puzzle,'' where measured neutron lifetimes differ depending on the measurement methods, an experiment with pulsed neutron beam at J-PARC is in progress. In this experiment, neutrons are bunched into 40-cm lengths using a spin flip chopper (SFC), where the statistical sensitivity was limited by the aperture size of the SFC. The SFC comprises three sets of magnetic supermirrors and two resonant spin flippers. In this paper, we discuss an upgrade to enlarge the apertures of the SFC. With this upgrade, the statistics per unit time of the neutron lifetime experiment increased by a factor of 2.8, while maintaining a signal-to-noise ratio of 250-400 comparable to the previous one. Consequently, the time required to reach a precision of 1 s in the neutron lifetime experiment was reduced from 590 to 170 days, which is a significant reduction in time. This improvement in statistic will also contribute to the reduction of systematic uncertainties, such as background evaluation, fostering further advancements in the neutron lifetime experiments at J-PARC.

physics.ins-det↗

Investigation of $K^+K^-$ pairs in the effective mass region near $2m_K$

The DIRAC experiment at CERN investigated in the reaction $\rm{p}(24~\rm{GeV}/c) + Ni$ the particle pairs $K^+K^-, π^+ π^-$ and $p \bar{p}$ with relative momentum $Q$ in the pair system less than 100 MeV/c. Because of background influence studies, DIRAC explored three subsamples of $K^+K^-$ pairs, obtained by subtracting -- using time-of-flight (TOF) technique -- background from initial $Q$ distributions with $K^+K^-$ sample fractions more than 70\%, 50\% and 30\%. The corresponding pair distributions in $Q$ and in its longitudinal projection $Q_L$ were analyzed first in a Coulomb model, which takes into account only Coulomb final state interaction (FSI) and assuming point-like pair production. This Coulomb model analysis leads to a $K^+K^-$ yield increase of about four at $Q_L=0.5$ MeV/c compared to 100 MeV/c. In order to study contributions from strong interaction, a second more sophisticated model was applied, considering besides Coulomb FSI also strong FSI via the resonances $f_0(980)$ and $a_0(980)$ and a variable distance $r^*$ between the produced $K$ mesons. This analysis was based on three different parameter sets for the pair production. For the 70\% subsample and with best parameters, $3680\pm 370$ $K^+K^-$ pairs was found to be compared to $3900\pm 410$ $K^+K^-$ extracted by means of the Coulomb model. Knowing the efficiency of the TOF cut for background suppression, the total number of detected $K^+K^-$ pairs was evaluated to be around $40000\pm 10\%$, which agrees with the result from the 30\% subsample. The $K^+K^-$ pair number in the 50\% subsample differs from the two other values by about three standard deviations, confirming -- as discussed in the paper -- that experimental data in this subsample is less reliable.

hep-ex↗

Precise Neutron Lifetime Measurement Using Pulsed Neutron Beams at J-PARC

A neutron decays into a proton, an electron, and an anti-neutrino through the beta-decay process. The decay lifetime ($\sim$880 s) is an important parameter in the weak interaction. For example, the neutron lifetime is a parameter used to determine the |$V_{\rm ud}$| parameter of the CKM quark mixing matrix. The lifetime is also one of the input parameters for the Big Bang Nucleosynthesis, which predicts light element synthesis in the early universe. However, experimental measurements of the neutron lifetime today are significantly different (8.4 s or 4.0$σ$) depending on the methods. One is a bottle method measuring surviving neutron in the neutron storage bottle. The other is a beam method measuring neutron beam flux and neutron decay rate in the detector. There is a discussion that the discrepancy comes from unconsidered systematic error or undetectable decay mode, such as dark decay. A new type of beam experiment is performed at the BL05 MLF J-PARC. This experiment measured neutron flux and decay rate simultaneously with a time projection chamber using a pulsed neutron beam. We will present the world situation of neutron lifetime and the latest results at J-PARC.

hep-ex↗

Neutron lifetime measurement with pulsed cold neutrons

The neutron lifetime has been measured by comparing the decay rate with the reaction rate of $^3$He nuclei of a pulsed neutron beam from the spallation neutron source at the Japan Proton Accelerator Research Complex (J-PARC). The decay rate and the reaction rate were determined by simultaneously detecting electrons from the neutron decay and protons from the $^3$He(n,p)$^3$H reaction using a gas chamber of which working gas contains diluted $^3$He. The measured neutron lifetime was $898\,\pm\,10\,_{\rm stat}\,^{+15}_{-18}\,_{\rm sys}\,$s.

hep-ex↗

In Memory of Prof. Hidekuni Takekoshi

A memorial to Prof. Hidekuni Hidekoshi, Kyoto University, Japan - an accelerator pioneer in Japan, teacher, mentor, friend, unassuming but knowing his accomplishments and worth, frugal but generous, enjoying life. Japanese contributions given in Japanese and English, English in English.

physics.hist-ph↗

Design and performance of a high-pressure xenon gas TPC as a prototype for a large-scale neutrinoless double-beta decay search

A high-pressure xenon gas time projection chamber, with a unique cellular readout structure based on electroluminescence, has been developed for a large-scale neutrinoless double-beta decay search. In order to evaluate the detector performance and validate its design, a 180~L size prototype is being constructed and its commissioning with partial detector has been performed. The obtained energy resolution at 4.0~bar is 1.73 $\pm$ 0.07% (FWHM) at 511 keV. The energy resolution at the $^{136}$Xe neutrinoless double-beta decay Q-value is estimated to be between 0.79 and 1.52% (FWHM) by extrapolation. Reconstructed event topologies show patterns peculiar to track end-point which can be used to distinguish $0νββ$ signals from gamma-ray backgrounds.

physics.ins-det↗

AXEL: High-pressure Xe gas TPC for BG-free $0\nu2β$ decay search

AXEL is a high-pressure xenon gas time projection chamber for neutrinoless double-beta decay (0n2b) search. The AXEL has a unique readout system called ELCC which has a cellular structure and photosensors to detect electroluminescence light produced by ionization electrons. We demonstrated the performance of the ELCC with a small prototype detector (AXEL-HP10L). The obtained energy resolution corresponds to 0.82 -- 1.74% (FWHM) at the 0n2b Q-value. We are constructing a new prototype (AXEL-HP180L) in order to study the energy resolution at the Q-value of 0n2b with a new design of ELCC with unit structure, newly developed electronics board, field-shaping electrodes, and Cockcroft-Walton-type high voltage power supply. For a future 1-ton scale large AXEL detector, we are developing new background-reduction techniques; topology identification with machine learning, positive-ion detection, and active-shield options.

physics.ins-det↗

Improved determination of thermal cross section of 14N(n,p)14C for the neutron lifetime measurement

In a neutron lifetime measurement at the Japan Proton Accelerator Complex, the neutron lifetime is calculated by the neutron decay rate and the incident neutron flux. The flux is obtained due to counting the protons emitted from the neutron absorption reaction of ${}^{3}{\rm He}$ gas, which is diluted in a mixture of working gas in a detector. Hence, it is crucial to determine the amount of ${}^{3}{\rm He}$ in the mixture. In order to improve the accuracy of the number density of the ${}^{3}{\rm He}$ nuclei, we suggested to use the ${}^{14}{\rm N}({\rm n},{\rm p}){}^{14}{\rm C}$ reaction as a reference because this reaction involves similar kinetic energy as the ${}^{3}{\rm He}({\rm n},{\rm p}){}^{3}{\rm H}$ reaction and a smaller reaction cross section to introduce reasonable large partial pressure. The uncertainty of the recommended value of the cross section, however, is not satisfied with our requirement. In this paper, we report the most accurate experimental value of the cross section of the ${}^{14}{\rm N}({\rm n},{\rm p}){}^{14}{\rm C}$ reaction at a neutron velocity of 2200 m/s, measured relative to the ${}^{3}{\rm He}({\rm n},{\rm p}){}^{3}{\rm H}$ reaction. The result was 1.868 $\pm$ 0.003 (stat.) $\pm$ 0.006 (sys.) b. Additionally, the cross section of the ${}^{17}{\rm O}({\rm n},{\rm α}){}^{14}{\rm C}$ reaction at the neutron velocity is also redetermined as 249 $\pm$ 6 mb.

nucl-ex↗

Lower critical field measurement of NbN multilayer thin film superconductor at KEK

The multilayer thin film structure of the superconductor has been proposed by A. Gurevich to enhance the maximum gradient of SRF cavities. The lower critical field Hc1 at which the vortex starts penetrating the superconducting material will be improved by coating Nb with thin film superconductor such as NbN. It is expected that the enhancement of Hc1 depends on the thickness of each layer. In order to determine the optimum thickness of each layer and to compare the measurement results with the theoretical prediction proposed by T. Kubo, we developed the Hc1 measurement system using the third harmonic response of the applied AC magnetic field at KEK. For the Hc1 measurement without the influence of the edge or the shape effects, the AC magnetic field can be applied locally by the solenoid coil of 5mm diameter in our measurement system. ULVAC made the NbN-SiO2 multilayer thin film samples of various NbN thicknesses. In this report, the measurement result of the bulk Nb sample and NbN-SiO2 multilayer thin film samples of different thickness of NbN layer will be discussed.

physics.acc-ph↗

Evaluation of the superconducting characteristics of multi-layer thin-film structures of NbN and SiO$_2$ on pure Nb substrate

In recent years, it has been pointed out that the maximum accelerating gradient of a superconducting RF cavity can be increased by coating the inner surface of the cavity with a multilayer thin-film structure consisting of alternating insulating and superconducting layers. In this structure, the principal parameter that limits the performance of the cavity is the critical magnetic field or effective $H_{C1}$ at which vortices begin penetrating into the superconductor layer. This is predicted to depend on the combination of the film thickness. We made samples that have a NbN/SiO$_2$ thin-film structure on a pure Nb substrate with several layers of NbN film deposited using DC magnetron sputtering method. Here, we report the measurement results of effective $H_{C1}$ of NbN/SiO$_2$(30 nm)/Nb multilayer samples with thicknesses of NbN layers in the range from 50 nm to 800 nm by using the third-harmonic voltage method. Experimental results show that an optimum thickness exists, which increases the effective $H_{C1}$ by 23.8 %.

physics.acc-ph↗

A New Approach for Measuring the Muon Anomalous Magnetic Moment and Electric Dipole Moment

This paper introduces a new approach to measure the muon magnetic moment anomaly $a_μ = (g-2)/2$, and the muon electric dipole moment (EDM) $d_μ$ at the J-PARC muon facility. The goal of our experiment is to measure $a_μ$ and $d_μ$ using an independent method with a factor of 10 lower muon momentum, and a factor of 20 smaller diameter storage-ring solenoid compared with previous and ongoing muon $g-2$ experiments with unprecedented quality of the storage magnetic field. Additional significant differences from the present experimental method include a factor of 1,000 smaller transverse emittance of the muon beam (reaccelerated thermal muon beam), its efficient vertical injection into the solenoid, and tracking each decay positron from muon decay to obtain its momentum vector. The precision goal for $a_μ$ is statistical uncertainty of 450 part per billion (ppb), similar to the present experimental uncertainty, and a systematic uncertainty less than 70 ppb. The goal for EDM is a sensitivity of $1.5\times 10^{-21}~e\cdot\mbox{cm}$.

physics.ins-det↗

First measurement of a long-lived $π^+ π^-$ atom lifetime

The adapted DIRAC experiment at the CERN PS accelerator observed for the first time long-lived hydrogen-like $π^+π^-$ atoms, produced by protons hitting a beryllium target. A part of these atoms crossed the gap of 96~mm and got broken up in the 2.1~\textmu{}m thick platinum foil. Analysing the observed number of atomic pairs, $n_A^L= \left.436^{+157}_{-61}\right|_\mathrm{tot}$, the lifetime of the 2$p$ state is found to be ${τ_{2p}=(\left.0.45^{+1.08}_{-0.30}\right|_\mathrm{tot}) \cdot10^{-11}}$s, not contradicting the corresponding QED $2p$ state lifetime ${τ_{2p}^\mathrm{QED}=1.17 \cdot 10^{-11}}$s. This lifetime value is three orders of magnitude larger than our previously measured value of the $π^+π^-$ atom ground state lifetime $τ=(\left.3.15^{+0.28}_{-0.26}\right|_\mathrm{tot})\cdot 10^{-15}$s. Further studies of long-lived $π^+π^-$ atoms will allow to measure energy differences between $p$ and $s$ atomic states and so to determine $ππ$ scattering lengths with the aim to check QCD predictions.

hep-ex↗

Measurement of the $πK$ atom lifetime and the $πK$ scattering length

After having announced the statistically significant observation (5.6~$σ$) of the new exotic $πK$ atom, the DIRAC experiment at the CERN proton synchrotron presents the measurement of the corresponding atom lifetime, based on the full $πK$ data sample: $τ= (5.5^{+5.0}_{-2.8}) \cdot 10^{-15}s$. By means of a precise relation ($<1\%$) between atom lifetime and scattering length, the following value for the S-wave isospin-odd $πK$ scattering length $a_0^{-}~=~\frac{1}{3}(a_{1/2}-a_{3/2})$ has been derived: $\left|a_0^-\right| = (0.072^{+0.031}_{-0.020}) M_π^{-1}$.

hep-ex↗

Development of time projection chamber for precise neutron lifetime measurement using pulsed cold neutron beams

A new time projection chamber (TPC) was developed for neutron lifetime measurement using a pulsed cold neutron spallation source at the Japan Proton Accelerator Research Complex (J-PARC). Managing considerable background events from natural sources and the beam radioactivity is a challenging aspect of this measurement. To overcome this problem, the developed TPC has unprecedented features such as the use of polyether-ether-ketone plates in the support structure and internal surfaces covered with $^6$Li-enriched tiles to absorb outlier neutrons. In this paper, the design and performance of the new TPC are reported in detail.

physics.ins-det↗

First $πK$ atom lifetime and $πK$ scattering length measurements

The results of a search for hydrogen-like atoms consisting of $π^{\mp}K^{\pm}$ mesons are presented. Evidence for $πK$ atom production by 24 GeV/c protons from CERN PS interacting with a nickel target has been seen in terms of characteristic $πK$ pairs from their breakup in the same target ($178 \pm 49$) and from Coulomb final state interaction ($653 \pm 42$). Using these results the analysis yields a first value for the $πK$ atom lifetime of $τ=(2.5_{-1.8}^{+3.0})$ fs and a first model-independent measurement of the S-wave isospin-odd $πK$ scattering length $\left|a_0^-\right|=\frac{1}{3}\left|a_{1/2}-a_{3/2}\right|= \left(0.11_{-0.04}^{+0.09} \right)M_π^{-1}$ ($a_I$ for isospin $I$).

nucl-ex↗

Present status and first results of the final focus beam line at the KEK Accelerator Test Facility

ATF2 is a final-focus test beam line which aims to focus the low emittance beam from the ATF damping ring to a vertical size of about 37 nm and to demonstrate nanometer level beam stability. Several advanced beam diagnostics and feedback tools are used. In December 2008, construction and installation were completed and beam commissioning started, supported by an international team of Asian, European, and U.S. scientists. The present status and first results are described.

physics.acc-ph↗