Searcharxiv⌕ Search

arXiv subjects

Y. Ma

Publications and source records attributed to Y. Ma.

At least 109 records · Page 6Linked to original sources

"$\mathbf{{\textit K^-}{\textit p}{\textit p}}$", a ${\overline{K}}$-Meson Nuclear Bound State, Observed in $^{3}{\rm He}({K^-}, Λ p)n$ Reactions

We observed a distinct peak in the $Λp$ invariant mass spectrum of $^{3}{\rm He}(K^-, \, Λp)n$, well below the mass threshold of $m_K + 2 m_p$. By selecting a relatively large momentum-transfer region $q = 350 \sim 650$ MeV/$c$, one can clearly separate the peak from the quasi-free process, $\overline{K}N \rightarrow \overline{K}N$ followed by the non-resonant absorption by the two spectator-nucleons $\overline{K}NN \rightarrow ΛN $. We found that the simplest fit to the observed peak gives us a Breit-Wigner pole position at $B_{\rm {\it Kpp}} = 47 \pm 3 \, (stat.) \,^{+3}_{-6} \,(sys.)$ MeV having a width $Γ_{\rm {\it Kpp}} = 115 \pm 7 \, (stat.) \,^{+10}_{-9} \,(sys.)$ MeV, and the $S$-wave Gaussian reaction form-factor parameter $Q_{\rm {\it Kpp}} = 381 \pm 14 \, (stat.)\,^{+57}_{-0} \,(sys.)$ MeV/$c$, as a new form of the nuclear bound system with strangeness -- "$K^-pp$".

nucl-ex↗

Single-loop realization of arbitrary non-adiabatic holonomic single-qubit quantum gates in a superconducting circuit

Geometric phases are noise-resilient, and thus provide a robust way towards high fidelity quantum manipulation. Here we experimentally demonstrate arbitrary non-adiabatic holonomic single-qubit quantum gates for both a superconducting transmon qubit and a microwave cavity in a single-loop way. In both cases, an auxiliary state is utilized, and two resonant microwave drives are simultaneously applied with well-controlled but varying amplitudes and phases for the arbitrariness of the gate. The resulting gates on the transmon qubit achieve a fidelity of 0.996 characterized by randomized benchmarking and the ones on the cavity show an averaged fidelity of 0.978 based on a full quantum process tomography. In principle, a nontrivial two-qubit holonomic gate between the qubit and the cavity can also be realized based on our presented experimental scheme. Our experiment thus paves the way towards practical non-adiabatic holonomic quantum manipulation with both qubits and cavities in a superconducting circuit.

quant-ph↗

Electroluminescence pulse shape and electron diffusion in liquid argon measured in a dual-phase TPC

We report the measurement of the longitudinal diffusion constant in liquid argon with the DarkSide-50 dual-phase time projection chamber. The measurement is performed at drift electric fields of 100 V/cm, 150 V/cm, and 200 V/cm using high statistics $^{39}$Ar decays from atmospheric argon. We derive an expression to describe the pulse shape of the electroluminescence signal (S2) in dual-phase TPCs. The derived S2 pulse shape is fit to events from the uppermost portion of the TPC in order to characterize the radial dependence of the signal. The results are provided as inputs to the measurement of the longitudinal diffusion constant DL, which we find to be (4.12 $\pm$ 0.04) cm$^2$/s for a selection of 140keV electron recoil events in 200V/cm drift field and 2.8kV/cm extraction field. To study the systematics of our measurement we examine datasets of varying event energy, field strength, and detector volume yielding a weighted average value for the diffusion constant of (4.09 $\pm$ 0.09) cm$^2$ /s. The measured longitudinal diffusion constant is observed to have an energy dependence, and within the studied energy range the result is systematically lower than other results in the literature.

physics.ins-det↗

Temporal diagnostics of femtosecond electron bunches with complex structures using sparsity-based algorithm

Femtosecond electron bunches with complex temporal structures play a crucial role in THz generation, free-electron lasers and plasma wakefield accelerators. The ultrashort electron pulse duration can be reconstructed from the coherent transition radiation (CTR) spectrum based on prior knowledge. A weighted greedy sparse phase retrieval (WGESPAR) algorithm is developed to reduce the ambiguities for reconstructing the distribution of the beam current. This algorithm achieves better performance than iterative algorithms, especially for truncated noisy spectra of multibunch structures. Based on the WGESPAR algorithm, the complex temporal structures of femtosecond electron bunches generated from laser wakefield accelerators can be successfully reconstructed.

physics.acc-ph↗

The Electronics, Trigger and Data Acquisition System for the Liquid Argon Time Projection Chamber of the DarkSide-50 Search for Dark Matter

The DarkSide-50 experiment at the Laboratori Nazionali del Gran Sasso is a search for dark matter using a dual phase time projection chamber with 50 kg of low radioactivity argon as target. Light signals from interactions in the argon are detected by a system of 38 photo-multiplier tubes (PMTs), 19 above and 19 below the TPC volume inside the argon cryostat. We describe the electronics which processes the signals from the photo-multipliers, the trigger system which identifies events of interest, and the data-acquisition system which records the data for further analysis. The electronics include resistive voltage dividers on the PMTs, custom pre-amplifiers mounted directly on the PMT voltage dividers in the liquid argon, and custom amplifier/discriminators (at room temperature). After amplification, the PMT signals are digitized in CAEN waveform digitizers, and CAEN logic modules are used to construct the trigger, the data acquisition system for the TPC is based on the Fermilab "artdaq" software. The system has been in operation since early 2014.

physics.ins-det↗

CALIS - a CALibration Insertion System for the DarkSide-50 dark matter search experiment

This paper describes the design, fabrication, commissioning and use of a CALibration source Insertion System (CALIS) in the DarkSide-50 direct dark matter search experiment. CALIS deploys radioactive sources into the liquid scintillator veto to characterize the detector response and detection efficiency of the DarkSide-50 Liquid Argon Time Projection Chamber, and the surrounding 30 t organic liquid scintillator neutron veto. It was commissioned in September 2014 and has been used successfully in several gamma and neutron source campaigns since then. A description of the hardware and an excerpt of calibration analysis results are given below.

physics.ins-det↗

Simulation of argon response and light detection in the DarkSide-50 dual phase TPC

A Geant4-based Monte Carlo package named G4DS has been developed to simulate the response of DarkSide-50, an experiment operating since 2013 at LNGS, designed to detect WIMP interactions in liquid argon. In the process of WIMP searches, DarkSide-50 has achieved two fundamental milestones: the rejection of electron recoil background with a power of ~10^7, using the pulse shape discrimination technique, and the measurement of the residual 39Ar contamination in underground argon, ~3 orders of magnitude lower with respect to atmospheric argon. These results rely on the accurate simulation of the detector response to the liquid argon scintillation, its ionization, and electron-ion recombination processes. This work provides a complete overview of the DarkSide Monte Carlo and of its performance, with a particular focus on PARIS, the custom-made liquid argon response model.

physics.ins-det↗

Simulating Molecular Spectroscopy with Circuit Quantum Electrodynamics

Spectroscopy is a crucial laboratory technique for understanding quantum systems through their interactions with electromagnetic radiation. Particularly, spectroscopy is capable of revealing the physical structure of molecules, leading to the development of the maser - the forerunner of the laser. However, real-world applications of molecular spectroscopy are mostly confined to equilibrium states, due to computational and technological constraints; a potential breakthrough can be achieved by utilizing the emerging technology of quantum simulation. Here we experimentally demonstrate that a superconducting quantum simulator is capable of generating molecular spectra for both equilibrium and non-equilibrium states, reliably producing the vibronic structure of the molecules. Furthermore, our quantum simulator is applicable not only to molecules with a wide range of electronic-vibronic coupling strength characterized by the Huang-Rhys parameter, but also to molecular spectra not readily accessible under normal laboratory conditions. These results point to a new direction for predicting and understanding molecular spectroscopy, exploiting the power of quantum simulation.

quant-ph↗

Converting quasiclassical states into arbitrary Fock state superpositions in a superconducting cavity

We propose and experimentally demonstrate a new method to generate arbitrary Fock-state superpositions in a superconducting quantum circuit, where a qubit is dispersively coupled to a microwave cavity mode without the need of fine-frequency tuning. Here the qubit is used to conditionally modulate the probability amplitudes of the Fock state components of a coherent state to those of the desired superposition state, instead of pumping photons one by one into the cavity as in previous schemes. Our method does not require the adjustment of the qubit frequency during the cavity state preparation, and is more robust to noise and accumulation of experimental errors compared to previous ones. Using the method, we experimentally generate high-fidelity phase eigenstates under various Hilbert-space dimensions and squeezed states, which are useful for quantum walk and high-precision measurements.

quant-ph↗

Hard Two-Photon Contribution to Elastic Lepton-Proton Scattering: Determined by the OLYMPUS Experiment

The OLYMPUS collaboration reports on a precision measurement of the positron-proton to electron-proton elastic cross section ratio, $R_{2γ}$, a direct measure of the contribution of hard two-photon exchange to the elastic cross section. In the OLYMPUS measurement, 2.01~GeV electron and positron beams were directed through a hydrogen gas target internal to the DORIS storage ring at DESY. A toroidal magnetic spectrometer instrumented with drift chambers and time-of-flight scintillators detected elastically scattered leptons in coincidence with recoiling protons over a scattering angle range of $\approx 20\degree$ to $80\degree$. The relative luminosity between the two beam species was monitored using tracking telescopes of interleaved GEM and MWPC detectors at $12\degree$, as well as symmetric Møller/Bhabha calorimeters at $1.29\degree$. A total integrated luminosity of 4.5~fb$^{-1}$ was collected. In the extraction of $R_{2γ}$, radiative effects were taken into account using a Monte Carlo generator to simulate the convolutions of internal bremsstrahlung with experiment-specific conditions such as detector acceptance and reconstruction efficiency. The resulting values of $R_{2γ}$, presented here for a wide range of virtual photon polarization $0.456<ε<0.978$, are smaller than some hadronic two-photon exchange calculations predict, but are in reasonable agreement with a subtracted dispersion model and a phenomenological fit to the form factor data.

nucl-ex↗

Effect of Low Electric Fields on Alpha Scintillation Light Yield in Liquid Argon

Measurements were made of scintillation light yield of alpha particles from the $^{222}$Rn decay chain within the DarkSide-50 liquid argon time projection chamber. The light yield was found to increase as the applied electric field increased, with alphas in a 200 V/cm electric field exhibiting a 2% increase in light yield compared to alphas in no field.

physics.ins-det↗

First application of superconducting transition-edge-sensor microcalorimeters to hadronic-atom x-ray spectroscopy

High-resolution pionic-atom x-ray spectroscopy was performed with an x-ray spectrometer based on a 240-pixel array of superconducting transition-edge-sensor (TES) microcalorimeters at the piM1 beam line of the Paul Scherrer Institute. X-rays emitted by pionic carbon via the 4f->3d transition and the parallel 4d->3p transition were observed with a full-width-at-half-maximum energy resolution of 6.8 eV at 6.4 keV. Measured x-ray energies are consistent with calculated electromagnetic values which considered the strong-interaction effect assessed via the Seki-Masutani potential for the 3p energy level, and favor the electronic population of two filled 1s electrons in the K-shell. Absolute energy calibration with an uncertainty of 0.1 eV was demonstrated under a high-rate hadron beam condition of 1.45 MHz. This is the first application of a TES spectrometer to hadronic-atom x-ray spectroscopy and is an important milestone towards next-generation high-resolution kaonic-atom x-ray spectroscopy.

physics.ins-det↗

The Electronics and Data Acquisition System for the DarkSide-50 Veto Detectors

DarkSide-50 is a detector for dark matter candidates in the form of weakly interacting massive particles (WIMPs). It utilizes a liquid argon time projection chamber (LAr TPC) for the inner main detector. The TPC is surrounded by a liquid scintillator veto (LSV) and a water Cherenkov veto detector (WCV). The LSV and WCV, both instrumented with PMTs, act as the neutron and cosmogenic muon veto detectors for DarkSide-50. This paper describes the electronics and data acquisition system used for these two detectors.

physics.ins-det↗

Results from the first use of low radioactivity argon in a dark matter search

Liquid argon is a bright scintillator with potent particle identification properties, making it an attractive target for direct-detection dark matter searches. The DarkSide-50 dark matter search here reports the first WIMP search results obtained using a target of low-radioactivity argon. DarkSide-50 is a dark matter detector, using two-phase liquid argon time projection chamber, located at the Laboratori Nazionali del Gran Sasso. The underground argon is shown to contain Ar-39 at a level reduced by a factor (1.4 +- 0.2) x 10^3 relative to atmospheric argon. We report a background-free null result from (2616 +- 43) kg d of data, accumulated over 70.9 live-days. When combined with our previous search using an atmospheric argon, the 90 % C.L. upper limit on the WIMP-nucleon spin-independent cross section based on zero events found in the WIMP search regions, is 2.0 x 10^-44 cm^2 (8.6 x 10^-44 cm^2, 8.0 x 10^-43 cm^2) for a WIMP mass of 100 GeV/c^2 (1 TeV/c^2 , 10 TeV/c^2).

astro-ph.CO↗

Structure near $K^-$+$p$+$p$ threshold in the in-flight $^3$He$(K^-,Λp)n$ reaction

To search for an S= -1 di-baryonic state which decays to $Λp$, the $ {\rm{}^3He}(K^-,Λp)n_{missing}$ reaction was studied at 1.0 GeV/$c$. Unobserved neutrons were kinematically identified from the missing mass $M_X$ of the $ {\rm{}^3He}(K^-,Λp)X$ reaction in order to have a large acceptance for the $Λpn$ final state. The observed $Λp n$ events, distributed widely over the kinematically allowed region of the Dalitz plot, establish that the major component comes from a three nucleon absorption process. A concentration of events at a specific neutron kinetic energy was observed in a region of low momentum transfer to the $Λp$. To account for the observed peak structure, the simplest S-wave pole was assumed to exist in the reaction channel, having Breit-Wigner form in energy and with a Gaussian form-factor. A minimum $χ^2$ method was applied to deduce its mass $M_X\ =$ 2355 $ ^{+ 6}_{ - 8}$ (stat.) $ \pm 12$ (syst.) MeV/c$^2$, and decay-width $Γ_X\ = $ 110 $ ^{+ 19}_{ - 17}$ (stat.) $ \pm 27$ (syst.) MeV/c$^2$, respectively. The form factor parameter $Q_X \sim$ 400 MeV/$c$ implies that the range of interaction is about 0.5

nucl-ex↗

Absolute Energy Calibration of X-ray TESs with 0.04 eV Uncertainty at 6.4 keV in a Hadron-Beam Environment

A performance evaluation of superconducting transition-edge sensors (TESs) in the environment of a pion beam line at a particle accelerator is presented. Averaged across the 209 functioning sensors in the array, the achieved energy resolution is 5.2 eV FWHM at Co $K_α$ (6.9 keV) when the pion beam is off and 7.3 eV at a beam rate of 1.45 MHz. Absolute energy uncertainty of $\pm$0.04 eV is demonstrated for Fe $K_α$ (6.4 keV) with in-situ energy calibration obtained from other nearby known x-ray lines. To achieve this small uncertainty, it is essential to consider the non-Gaussian energy response of the TESs and thermal cross-talk pile-up effects due to charged-particle hits in the silicon substrate of the TES array.

physics.ins-det↗

The veto system of the DarkSide-50 experiment

Nuclear recoil events produced by neutron scatters form one of the most important classes of background in WIMP direct detection experiments, as they may produce nuclear recoils that look exactly like WIMP interactions. In DarkSide-50, we both actively suppress and measure the rate of neutron-induced background events using our neutron veto, composed of a boron-loaded liquid scintillator detector within a water Cherenkov detector. This paper is devoted to the description of the neutron veto system of DarkSide-50, including the detector structure, the fundamentals of event reconstruction and data analysis, and basic performance parameters.

physics.ins-det↗

Resonantly excited betatron hard X-Rays from Ionization Injected Electron Beam in a Laser Plasma Accelerator

A new scheme for bright hard x-ray emission from laser wakefield electron accelerator is reported, where pure nitrogen gas is adopted. Intense Betatron x-ray beams are generated from ionization injected K-shell electrons of nitrogen into the accelerating wave bucket. The x-ray radiation shows synchrotron-like spectrum with total photon yield 8$\times$10$^8$/shot and $10^8$ over 110keV. In particular, the betatron hard x-ray photon yield is 10 times higher compared to the case of helium gas under the same laser parameters. Particle-in-cell simulation suggests that the enhancement of the x-ray yield results from ionization injection, which enables the electrons to be quickly accelerated to the driving laser region for subsequent betatron resonance. Employing the present scheme,the single stage nitrogen gas target could be used to generate stable high brightness betatron hard x-ray beams.

physics.plasm-ph↗