Searcharxiv⌕ Search

arXiv subjects

Y. P. Viyogi

Publications and source records attributed to Y. P. Viyogi.

15 recordsLinked to original sources

Time resolution and characteristic study of MWPC detectors with different Argon based gas

A prototype of Multi-Wire Proportional Chambers (MWPC) has been fabricated for the study of its various characteristics. The detector contains gold-coated tungsten wires (20 $μm$ diameter) on the anode frame, with a pitch of 2.8 mm. The gap between the anode and the cathode is 3 mm and the gap between anode and read-out is also 3 mm. Detailed study of MWPC in terms of gain, energy and timing resolution and efficiency measurements have been performed. The detector has been operated using Ar/CO$_{2}$ gas mixtures with 70:30 and 90:10 ratio. Energy spectrum of $^{55}$Fe X-ray source is obtained for the detector. The gain and energy resolution of the detector were calculated using X-ray spectrum. Time resolution is obtained $\sim$10 ns.

physics.ins-det↗

Physics Potential of the ICAL detector at the India-based Neutrino Observatory (INO)

The upcoming 50 kt magnetized iron calorimeter (ICAL) detector at the India-based Neutrino Observatory (INO) is designed to study the atmospheric neutrinos and antineutrinos separately over a wide range of energies and path lengths. The primary focus of this experiment is to explore the Earth matter effects by observing the energy and zenith angle dependence of the atmospheric neutrinos in the multi-GeV range. This study will be crucial to address some of the outstanding issues in neutrino oscillation physics, including the fundamental issue of neutrino mass hierarchy. In this document, we present the physics potential of the detector as obtained from realistic detector simulations. We describe the simulation framework, the neutrino interactions in the detector, and the expected response of the detector to particles traversing it. The ICAL detector can determine the energy and direction of the muons to a high precision, and in addition, its sensitivity to multi-GeV hadrons increases its physics reach substantially. Its charge identification capability, and hence its ability to distinguish neutrinos from antineutrinos, makes it an efficient detector for determining the neutrino mass hierarchy. In this report, we outline the analyses carried out for the determination of neutrino mass hierarchy and precision measurements of atmospheric neutrino mixing parameters at ICAL, and give the expected physics reach of the detector with 10 years of runtime. We also explore the potential of ICAL for probing new physics scenarios like CPT violation and the presence of magnetic monopoles.

physics.ins-det↗

Measurement of electrical properties of electrode materials for the bakelite Resistive Plate Chambers

Single gap (gas gap 2 mm) bakelite Resistive Plate Chamber (RPC) modules of various sizes from 10 cm \times 10 cm to 1 m \times 1 m have been fabricated, characterized and optimized for efficiency and time resolution. Thin layers of different grades of silicone compound are applied to the inner electrode surfaces to make them smooth and also to reduce the surface resistivity. In the silicone coated RPCs an efficiency > 90% and time resolution \sim 2 ns (FWHM) have been obtained for both the streamer and the avalanche mode of operation. Before fabrication of detectors the electrical properties such as bulk resistivity and surface resistivity of the electrode materials are measured carefully. Effectiveness of different silicone coating in modifying the surface resistivity was evaluated by an instrument developed for monitoring the I-V curve of a high resistive surface. The results indicate definite correlation of the detector efficiency for the atmospheric muons and the RPC noise rates with the surface resistivity and its variation with the applied bias voltage. It was also found that the surface resistivity varies for different grades of silicone material applied as coating, and the results are found to be consistent with the detector efficiency and noise rate measurements done with these RPCs.

physics.ins-det↗

Performances of silicone coated high resistive bakelite RPC

Performances of several single gap (gas gap 2 mm) prototype Resistive Plate Chambers (RPC) made of high resistive (ρ \sim 1010 - 1012 Ω cm) bakelite, commercially available in India have been studied in recent times. To make the inner electrode surfaces smooth, a thin coating of silicone has been applied. An efficiency > 90% and time resolution \sim 2 ns (FWHM) have been obtained for both the streamer and the avalanche mode. The induced charge distributions of those silicone coated RPC are studied and the results are presented. A numerical study on the effect of surface roughness of the resistive electrodes on the electric field of the device has been carried out using Garfield-neBEM code. A few results for a simplified model representing surface roughness, measured using a surface profilometer for the bakelite surfaces, have also been presented.

physics.ins-det↗

Performances of linseed oil-free bakelite RPC prototypes with cosmic ray muons

A comparative study has been performed on Resistive Plate Chambers (RPC) made of two different grades of bakelite paper laminates, produced and commercially available in India. The chambers, operated in the streamer mode using argon, tetrafluroethane and isobutane in 34:59:7 mixing ratio, are tested for the efficiency and the stability with cosmic rays. A particular grade of bakelite (P-120, NEMA LI-1989 Grade XXX), used for high voltage insulation in humid conditions, was found to give satisfactory performance with stable efficiency of > 96% continuously for more than 130 days. A thin coating of silicone fluid on the inner surfaces of the bakelite RPC is found to be necessary for operation of the detector.

physics.ins-det↗

Development of linseed oil-free bakelite resistive plate chambers

In this paper we would like to present a few characteristics of the Resistive Plate Chambers (RPC) made of a particular grade of bakelite paper laminates (P-120, NEMA LI-1989 Grade XXX), produced and commercially available in India. This particular grade is used for high voltage insulation in humid conditions. The chambers are tested with cosmic rays in the streamer mode using argon, tetrafluroethane and isobutane in 34:59:7 mixing ratio. In the first set of detectors made with such grade, a thin coating of silicone fluid on the inner surfaces of the bakelite was found to be necessary for operation of the detector. Those silicone coated RPCs were found to give satisfactory performance with stable efficiency of >90% continuously for a long period as reported earlier. Results of the crosstalk measurement of these silicone coated RPC will be presented in this paper. Very recently RPCs made with the same grade of bakelite but having better surface finish, are found to give equivalent performance even without any coating inside. Preliminary results of this type of RPCs are also being presented.

physics.ins-det↗

Study of timing properties of single gap high-resistive bakelite RPC

The time resolution for several single gap (2 mm) prototype Resistive Plate Chambers (RPC) made of high resistive (bulk resistivity ~ 10^10 - 10^12 ohm cm), 2 mm thick matt finished bakelite paper laminates with silicone coating on the inner surfaces, has been measured. The time resolution for all the modules has been found to be ~ 2 ns at the plateau region.

physics.ins-det↗

Development of bakelite based Resistive Plate Chambers

A Comparative study has been performed on Resistive Plate Chambers made of different grades of bakelite paper laminates, produced and commercially available in India. The chambers, operated in the streamer mode using argon : tetrafluroethane : isobutane in 34:59:7 mixing ratio, are tested with cosmic rays for the efficiency and the stability with cosmic rays. A particular grade of bakelite (P-120, NEMA LI-1989 Grade XXX), used for high voltage insulation in humid conditions, was found to give satisfactory performance with stable efficiency of > 96% continuously for more than 110 days. A silicone treatment of the inner surfaces of the bakelite RPC is found to be necessary for operation of the detector.

nucl-ex↗

Event-by-event study of DCC-like fluctuation in ultra-relativistic nuclear collisions

A method based on sliding window scheme is developed to search for patches in the pseudorapidity-azimuth plane, on an event-by-event basis, having unusual fluctuation in the neutral pion fraction which may arise due to the formation of Disoriented Chrial Condensates (DCC) in high energy nuclear collisions. The efficiency of the method to extract the patches and the purity of the extracted sample are studied for possible experimental situations.

nucl-ex↗

Search for DCC in relativistic heavy-ion collisions : Possibilities and Limitations

The experimental observation of disoriented chiral condensate is affected due to various physical and detector related effects. We study and quantify the strength of the experimental signal, ``neutral pion fraction'' within the framework of a simple DCC model, using the analysis methods based on the multi-resolution discrete wavelet technique and by evaluating the signal to background ratio. The scope and limitations of DCC search in heavy-ion collision experiments using various combination of detector systems are investigated.

nucl-ex↗

The STAR Photon Multiplicity Detector

Details concerning the design, fabrication and performance of STAR Photon Multiplicity Detector (PMD) are presented. The PMD will cover the forward region, within the pseudorapidity range 2.3--3.5, behind the forward time projection chamber. It will measure the spatial distribution of photons in order to study collective flow, fluctuation and chiral symmetry restoration.

nucl-ex↗

A Honeycomb Proportional Counter for Photon Multiplicity Measurement in the ALICE Experiment

A honeycomb detector consisting of a matrix of 96 closely packed hexagonal cells, each working as a proportional counter with a wire readout, was fabricated and tested at the CERN PS. The cell depth and the radial dimensions of the cell were small, in the range of 5-10 mm. The appropriate cell design was arrived at using GARFIELD simulations. Two geometries are described illustrating the effect of field shaping. The charged particle detection efficiency and the preshower characteristics have been studied using pion and electron beams. Average charged particle detection efficiency was found to be 98%, which is almost uniform within the cell volume and also within the array. The preshower data show that the transverse size of the shower is in close agreement with the results of simulations for a range of energies and converter thicknesses.

nucl-ex↗

Localized Domains of Disoriented Chiral Condensates

A new method to search for localized domains of disoriented chiral condensates (DCC) has been proposed by utilising the (eta-phi) phase space distributions of charged particles and photons. Using the discrete wavelet transformation (DWT) analysis technique, it has been found that the presence of DCC domains broadens the distribution of wavelet coefficients in comparison to that of normal events. Strength contours have been derived from the differences in rms deviations of these distributions by taking into account the size of DCC domains and the probability of DCC production in ultra-relativistic heavy ion collisions. This technique can be suitably adopted to experiments measuring multiplicities of charged particles and photons.

nucl-ex↗

A Preshower Photon Multiplicity Detector for the WA98 Experiment

A high granularity preshower detector has been fabricated and installed in the WA98 Experiment at the CERN SPS for measuring the spatial distribution of photons produced in the forward region in lead ion induced interactions. Photons are counted by detecting the preshower signal in plastic scintillator pads placed behind a 3 radiation length thick lead converter and applying a threshold on the scintillator signal to reject the minimum ionizing particles. Techniques to improve the imaging of the fibre and performance of the detector in the high multiplicity environment of lead-lead collisions are described. Using Monte-Carlo simulation methods and test beam data of pi- and e- at various energies the photon counting efficiency is estimated to be 68% for central and 73% for peripheral Pb+Pb collisions.

hep-ex↗