SearcharxivSearch

arXiv subjects

Y. Ramachers

Publications and source records attributed to Y. Ramachers.

At least 19 recordsLinked to original sources

Determining Absolute Neutrino Mass using Quantum Technologies

Next generation tritium decay experiments to determine the absolute neutrino mass require high-precision measurements of $β$-decay electron energies close to the kinematic end point. To achieve this, the development of high phase-space density sources of atomic tritium is required, along with the implementation of methods to control the motion of these atoms to allow extended observation times. A promising approach to efficiently and accurately measure the kinetic energies of individual $β$-decay electrons generated in these dilute atomic gases, is to determine the frequency of the cyclotron radiation they emit in a precisely characterised magnetic field. This cyclotron radiation emission spectroscopy technique can benefit from recent developments in quantum technologies. Absolute static-field magnetometry and electrometry, which is essential for the precise determination of the electron kinetic energies from the frequency of their emitted cyclotron radiation, can be performed using atoms in superpositions of circular Rydberg states. Quantum-limited microwave amplifiers will allow precise cyclotron frequency measurements to be made with maximal signal-to-noise ratios and minimal observation times. Exploiting the opportunities offered by quantum technologies in these key areas, represents the core activity of the Quantum Technologies for Neutrino Mass project. Its goal is to develop a new experimental apparatus that can enable a determination of the absolute neutrino mass with a sensitivity on the order of 10~meV/$c^2$.

hep-ex

Calorimeter commissioning of the SuperNEMO Demonstrator

The SuperNEMO experiment is searching for neutrinoless double beta decay of \textsuperscript{82}Se, with the unique combination of a tracking detector and a segmented calorimeter. This feature allows to detect the two electrons emitted in the decay and measure their individual energy and angular distribution. The SuperNEMO calorimeter consists of 712 plastic scintillator blocks readout by large PMTs. After the construction of the demonstrator calorimeter underground, we have performed its first commissioning using $γ$-particles from calibration sources or from the ambient radioactive background. This article presents the quality assurance tests of the SuperNEMO demonstrator calorimeter and its first time and energy calibrations, with the associated methods.

physics.ins-det

CdZnTe room-temperature semiconductor operation in liquid scintillator

We demonstrate the first operation of CdZnTe room-temperature detectors in a liquid scintillator environment. This work follows conceptually the Heusser-type detector method of operating HPGe detectors in liquid nitrogen and liquid argon but instead for a far more practical room-temperature ensemble with the aim of achieving ultra-low background levels for radiation detection.

nucl-ex

Energy resolution improvement in room-temperature CZT detectors

We present methods to improve the energy resolution of single-channel, room-temperature Cadmium-Zinc-Telluride (CZT) detectors. A new preamplifier design enables the acquisition of the actual transient current from the crystals and straightforward data analysis methods yield unprecedented energy resolution for our test-detectors. These consist of an eV-CAPture Plus crystal as standard and 1 cm cube Frisch collar crystals created in-house from low-grade coplanar grid detectors. Energy resolutions of 1.9% for our collar detectors and 0.8% for the eV crystal at 662 keV were obtained. The latter compares favourably to the best existing energy resolution results from pixel detectors.

physics.ins-det

First results on double beta decay modes of Cd, Te and Zn isotopes with the COBRA experiment

Four 1cm^3 CdZnTe semiconductor detectors were operated in the Gran Sasso National Laboratory to explore the feasibility of such devices for double beta decay searches as proposed for the COBRA experiment. The research involved background studies accompanied by measurements of energy resolution performed at the surface. Energy resolutions sufficient to reduce the contribution of two-neutrino double beta decay events to a negligible level for a large scale experiment have already been achieved and further improvements are expected. Using activity measurements of contaminants in all construction materials a background model was developed with the help of Monte Carlo simulations and major background sources were identified. A total exposure of 4.34 kg.days of underground data has been accumulated allowing a search for neutrinoless double beta decay modes of seven isotopes found in CdZnTe. Half-life limits (90% C.L.) are presented for decays to ground and excited states. Four improved lower limits have been obtained, including zero neutrino double electron capture transitions of Zn64 and Te120 to the ground state, which are 1.19*10^{17} years and 2.68*10^{15} years respectively.

nucl-ex

Fracture Processes Observed with A Cryogenic Detector

In the early stages of running of the CRESST dark matter search using sapphire detectors at very low temperature, an unexpectedly high rate of signal pulses appeared. Their origin was finally traced to fracture events in the sapphire due to the very tight clamping of the detectors. During extensive runs the energy and time of each event was recorded, providing large data sets for such phenomena. We believe this is the first time the energy release in fracture has been directly and accurately measured on a microscopic event-by-event basis. The energy threshold corresponds to the breaking of only a few hundred covalent bonds, a sensitivity some orders of magnitude greater than that of previous technique. We report some features of the data, including energy distributions, waiting time distributions, autocorrelations and the Hurst exponent. The energy distribution appear to follow a power law, $dN/dE\propto E^{-β}$, similar to the power law for earthquake magnitudes, and after appropriate translation, with a similar exponent. In the time domain,the waiting time $w$ or gap distribution between events has a power law behavior at small $w$ and an exponential fall-off at large $w,$ and can be fit $\propto w^{-α}e^{-w/w_0}$. The autocorrelation function shows time correlations lasting for substantial parts of an hour. An asymmetry is found around large events, with higher count rates after, as opposed to before,the large event .

physics.ins-det

Limits on WIMP dark matter using scintillating CaWO4 cryogenic detectors with active background suppression

We present first significant limits on WIMP dark matter by the phonon-light technique, where combined phonon and light signals from a scintillating cryogenic detector are used. Data from early 2004 with two 300 g CRESST-II prototype detector modules are presented, with a net exposure of 20.5 kg days. The modules consist of a CaWO4 scintillating ``target'' crystal and a smaller cryogenic light detector. The combination of phonon and light signals leads to a strong suppression of non-nuclear recoil backgrounds. Using this information to define an acceptance region for nuclear recoils we have 16 events from the two modules, corresponding to a rate for nuclear recoils between 12 and 40 keV of (0.87 +- 0.22) events/(kg day). This is compatible with the rate expected from neutron background, and most of these events lie in the region of the phonon-light plane anticipated for neutron-induced recoils. A particularly strong limit for WIMPs with coherent scattering results from selecting a region of the phonon-light plane corresponding to tungsten recoils, where the best module shows zero events.

astro-ph

The CRESST Dark Matter Search

We present first competitive results on WIMP dark matter using the phonon-light-detection technique. A particularly strong limit for WIMPs with coherent scattering results from selecting a region of the phonon-light plane corresponding to tungsten recoils. The observed count rate in the neutron band is compatible with the rate expected from neutron background. CRESST is presently being upgraded with a 66 channel SQUID readout system, a neutron shield and a muon veto system. This results in a significant improvement in sensitivity.

astro-ph

Detection of the Natural Alpha Decay of Tungsten

The natural alpha decay of 180W has been unambiguously detected for the first time. The alpha peak is found in a (gamma,beta and neutron)-free background spectrum. This has been achieved by the simultaneous measurement of phonon and light signals with the CRESST cryogenic detectors. A half-life of T1/2 = (1.8 +- 0.2) x 10^18 y and an energy release of Q = (2516.4 +- 1.1 (stat.) +- 1.2 (sys.)) keV have been measured. New limits are also set on the half-lives of the other naturally occurring tungsten isotopes.

nucl-ex

WIMP direct detection overview

This review on weakly interacting massive particle (WIMP) dark matter direct detection focuses on experimental approaches and the corresponding physics basics. The presentation is intended to provide a quick and concise introduction for non-specialists to this fast evolving topic of astroparticle physics.

astro-ph

Results and plans of the CRESST dark matter search

Data taken by CRESST in 2000 with a cryogenic detector system based on 262 g sapphire crystals is used to place limits on WIMP dark matter in the Galactic Halo. The detector is especially sensitive for low-mass WIMPS with spin-dependent cross sections and improves on existing limits in this region. CRESST is now preparing for a second phase, which will use a 10 kg detector consisting of 300 g CaWO4 crystals with simultaneous detection of phonons and scintillation light to reduce background.

astro-ph

The CRESST Experiment: Recent Results and Prospects

The CRESST experiment seeks hypothetical WIMP particles that could account for the bulk of dark matter in the Universe. The detectors are cryogenic calorimeters in which WIMPs would scatter elastically on nuclei, releasing phonons. The first phase of the experiment has successfully deployed several 262 g sapphire devices in the Gran Sasso underground laboratories. A main source of background has been identified as microscopic mechanical fracturing of the crystals, and has been eliminated, improving the background rate by up to three orders of magnitude at low energies, leaving a rate close to one count per day per kg and per keV above 10 keV recoil energy. This background now appears to be dominated by radioactivity, and future CRESST scintillating calorimeters which simultaneously measure light and phonons will allow rejection of a great part of it.

hep-ex

A New Model-Independent Method for Extracting Spin-Dependent Cross Section Limits from Dark Matter Searches

A new method is proposed for extracting limits on spin-dependent WIMP-nucleon interaction cross sections from direct detection dark matter experiments. The new method has the advantage that the limits on individual WIMP-proton and WIMP-neutron cross sections for a given WIMP mass can be combined in a simple way to give a model-independent limit on the properties of WIMPs scattering from both protons and neutrons in the target nucleus. Extension of the technique to the case of a target material consisting of several different species of nuclei is discussed.

hep-ph

Non-baryonic dark matter searches

The emphasis in this review about non-baryonic dark matter will be on experimental approaches to this fast evolving field of astroparticle physics, especially the direct detection method. The current status of experimental techniques will be reviewed and recent highlights as well as future plans will be introduced.

astro-ph

High-purity germanium detector ionization pulse shapes of nuclear recoils, gamma interactions and microphonism

Nuclear recoil measurements with high-purity Germanium detectors are very promising to directly detect dark matter candidates. The main background sources in such experiments are natural radioactivity and microphonic noise. Digital pulse shape analysis is an encouraging approach to reduce the background originating from the latter. To study the pulse shapes of nuclear recoil events we performed a neutron scattering experiment, which covered the ionization energy range from 20 to 80 keV. We have measured ionization efficiencies as well and found an excellent agreement with the theory of Lindhard. In a further experiment we measured pulse shapes of a radioactive gamma-source and found no difference to nuclear recoil pulse shapes. Pulse shapes originating from microphonics of a HPGe-detector are presented for the first time. A microphonic noise suppression method, crucial for dark matter direct detection experiments, can therefore be calibrated with pulse shapes from gamma-sources.

hep-ex

New limits on dark--matter WIMPs from the Heidelberg--Moscow experiment

New results after 0.69 kg yr of measurement with an enriched 76Ge detector of the Heidelberg--Moscow experiment with an active mass of 2.758 kg are presented. An energy threshold of 9 keV and a background level of 0.042 counts/(kg d keV) in the energy region between 15 keV and 40 keV was reached.The derived limits on the WIMP--nucleon cross section are the most stringent limits on spin--independent interactions obtained to date by using essentially raw data without background subtraction.

hep-ex

Background and Technical Studies for GENIUS as a Dark Matter Experiment

The GENIUS project is a proposal for a new dark matter detector, with an increased sensitivity of three orders of magnitude relative to existing direct dark matter detection experiments. We performed a technical study and calculated the main background sources for the relevant energy region in a detailed detector geometry. The achieved overall background level and detector performance confirm the outstanding potential of GENIUS as a powerful tool for the direct search of WIMPs in our Galaxy.

hep-ex

The GENIUS Project - Background and technical studies

The potential of GENIUS as a dark matter detector is discussed. A study was performed to demonstrate the good behaviour of the proposed detector design of naked HPGe-crystals in liquid nitrogen. The expected background components were simulated and are discussed in some detail.With the obtained background GENIUS could cover a large part of the favoured MSSM parameter-space.

hep-ex