SearcharxivSearch

arXiv subjects

Y. T. Wei

Publications and source records attributed to Y. T. Wei.

3 recordsLinked to original sources

Characterization of VUV4 SiPM for Liquid Argon Detector

Particle detectors based on liquid argon are now recognised as an attractive technology for dark matter direct detection and coherent elastic neutrino-nucleus scattering measurement. A program using a dual-phase liquid argon detector with a fiducial mass of 200~kg to detect coherent elastic neutrino-nucleus scattering at Taishan Nuclear Power Plant has been proposed. SiPMs will be used as the photon sensor because of their high radio-purity and high photon detection efficiency. S13370-6050CN SiPM, made by Hamamatsu, is a candidate for the detector. In this paper, the characterisation of S13370-6050CN SiPM, including the cross talk and after pulse probabilities at liquid argon temperature and the temperature dependence of break down voltage, dark counting rate and relative quantum efficiency were presented.

physics.ins-det

Using $^{22}$Na and $^{83{\rm m}}$Kr to calibrate and study the properties of scintillation in xenon-doped liquid argon

We have measured the properties of scintillation light in liquid argon doped with xenon concentrations from 165 ppm to 10,010 ppm using a $^{22}$Na source. The energy transfer processes in the xenon-doped liquid argon are discussed in detail, and a new waveform model is established and used to fit the average waveform. The time profile of the scintillation photon in the xenon-doped liquid argon and of the TPB emission are presented. The quantities of xenon-doped are controlled by a Mass Flow Controller which is calibrated via a Redusial Gas Analyzer to ensure that the xenon concentration is accurate. In addition, a successful test of $^{83{\rm m}}$Kr as a calibration source has been implemented in the xenon-doped liquid argon detector for the first time. By comparing the light yield of the $^{22}$Na and $^{83{\rm m}}$Kr, it can be concluded that the scintillation efficiency is almost same over the range of 41.5 keV to 511 keV.

physics.ins-det

Using Mineral Oil to Improve the Performance of Multi-Crystal Detector for Dark Matter Searching

The inorganic crystals have been widely used for dark matter direct searching for many decades. However, limited by the crystal growth technique, a lot of small crystals have to be used together for large target mass, which results in a degradation of light collection efficiency. An experiment was built up to study the degradation, and the method of soaking crystals into mineral oil to improve the efficiency as well as reduce the interface effect were proposed and validated. Good data and MC agreements were achieved in the experiment.

physics.ins-det