SearcharxivSearch

arXiv subjects

Yao Hao

Publications and source records attributed to Yao Hao.

9 recordsLinked to original sources

Develop and Optimize 5DCT Imaging Simulation and Reconstruction Methods

Purpose: To develop and optimize a 5DCT (3D + cardiac phase + respiratory phase) imaging simulation and reconstruction pipeline, and to compare two sinogram-space interpolation methods for reconstructing images at arbitrary combinations of cardiac and respiratory phase. Methods: Helical CT projections were simulated from the 4D XCAT phantom across a range of cardiac and respiratory motion states, with Poisson and electronic noise added. Ground-truth-matched volumes were generated at 5 cardiac phases and 10 respiratory amplitudes (50 total phase combinations). Because acquired projections are sparsely and unevenly distributed across this joint phase space, each target slice was reconstructed by interpolating rebinned sinogram rows to the target cardiac phase and respiratory amplitude, using either 2D scattered barycentric interpolation or 2D scattered local linear interpolation with a circular kernel for cardiac phase. Reconstructed volumes were compared to phantom ground truth using mean absolute error (MAE), and to conventional respiratory-gated 4DCT (r4DCT) reconstructed from the same simulated data. Results: Both interpolation methods eliminated the severe axial misalignment artifacts present when helical projections were reconstructed without phase-space interpolation. Local linear interpolation achieved lower MAE than barycentric interpolation across most tested conditions, with the largest improvement at low pitch. The 5DCT pipeline also produced respiratory-only volumes with fewer residual cardiac-motion artifacts than conventional r4DCT reconstructed from the same projection data, including at standard clinical pitch (0.1). Conclusions: 5DCT reconstruction using sinogram-space interpolation is feasible and can jointly resolve cardiac and respiratory motion with better accuracy than conventional 4DCT reconstruction.

physics.med-ph

Beam monitoring for radiotherapy from conventional to FLASH dose rates using Low Gain Avalanche Silicon detectors

We report the performance of low gain avalanche Silicon detectors (LGADs) for instantaneous electron and proton beam monitoring across dose rates ranging from conventional radiotherapy to the FLASH regime, benefiting from the fast response of these detectors of a few nanoseconds. The beam sources provide a dose rate greater than 40~Gy/s through pulses of widths 0.5, 1, 2 and 3~$μ$s for electron beams and 3, 5, 10 $μ$s for proton beams. Two different LGAD devices and silicon diodes are tested, yielding a linear dose response for electron beams up to $\sim$450~Gy/s and for proton beams up to $\sim$12~Gy/s. Beyond the linear regime the response continues to increase with a reduced slope and no true signal plateau is observed, at least up to 1800 Gy/s for electrons and 150 Gy/s for protons. This study contributes towards the instantaneous monitoring of increasingly intense flash beams for radiotherapy using fast detectors such as LGADs since measurements can be performed every fraction of $μ$s.

physics.med-ph

PIVM: Diffusion-Based Prior-Integrated Variation Modeling for Anatomically Precise Abdominal CT Synthesis

Abdominal CT data are limited by high annotation costs and privacy constraints, which hinder the development of robust segmentation and diagnostic models. We present a Prior-Integrated Variation Modeling (PIVM) framework, a diffusion-based method for anatomically accurate CT image synthesis. Instead of generating full images from noise, PIVM predicts voxel-wise intensity variations relative to organ-specific intensity priors derived from segmentation labels. These priors and labels jointly guide the diffusion process, ensuring spatial alignment and realistic organ boundaries. Unlike latent-space diffusion models, our approach operates directly in image space while preserving the full Hounsfield Unit (HU) range, capturing fine anatomical textures without smoothing. Source code is available at https://github.com/BZNR3/PIVM.

cs.CV

A Respiratory Motion Analysis for Guiding Stereotactic Arrhythmia Radiotherapy Motion Management

Stereotactic Arrhythmia Radiotherapy (STAR) treats ventricular tachycardia (VT) but requires internal target volume (ITV) expansions to compensate for cardiorespiratory motion. Current clinical r4DCT imaging methods are limited, and the reconstructed r4DCTs suffer from unmanaged cardiac motion artifacts that affect the quantitative assessment of respiratory motion. A groupwise surface-to-surface deformable image registration (DIR) algorithm, named gCGF, was developed. A novel principal component filtering (PCF) mechanism and a spatial smoothing mechanism were developed and incorporated into gCGF to iteratively register heart contours from an average respiratory-phase CT to ten r4DCT phases while removing random cardiac motion from the cyclic respiratory motion. The performance of the groupwise DIR was quantitatively validated using 8 digital phantoms with simulated cardiac artifacts. An ablation study was conducted to compare gCGF to another comparable state-of-the-art groupwise DIR method. gCGF was applied to r4DCTs of 20 STAR patients to analyze the respiratory motion of the heart. Validation on digital phantoms showed that gCGF achieved a mean target registration error of 0.63+-0.51 mm while successfully achieving phase smoothness and reducing cardiac motion artifacts. Among all STAR patients, the heart's maximum and mean respiratory motion magnitudes ranged from 3.6 to 7.9 mm and 1.0 mm to 2.6 mm. The peak-to-peak motion range was from 6.2 to 14.7 mm. For VT targets, the max and mean motion magnitude ranges were 3.0 to 6.7 mm and 0.8 to 2.9 mm, respectively. The peak-to-peak range was from 4.7 to 11.8 mm. Significant dominance of the first principal component of the motion direction was observed (p = 0).

physics.med-ph

A Vessel Bifurcation Landmark Pair Dataset for Abdominal CT Deformable Image Registration (DIR) Validation

Deformable image registration (DIR) is an enabling technology in many diagnostic and therapeutic tasks. Despite this, DIR algorithms have limited clinical use, largely due to a lack of benchmark datasets for quality assurance during development. To support future algorithm development, here we introduce our first-of-its-kind abdominal CT DIR benchmark dataset, comprising large numbers of highly accurate landmark pairs on matching blood vessel bifurcations. Abdominal CT image pairs of 30 patients were acquired from several public repositories as well as the authors' institution with IRB approval. The two CTs of each pair were originally acquired for the same patient on different days. An image processing workflow was developed and applied to each image pair: 1) Abdominal organs were segmented with a deep learning model, and image intensity within organ masks was overwritten. 2) Matching image patches were manually identified between two CTs of each image pair 3) Vessel bifurcation landmarks were labeled on one image of each image patch pair. 4) Image patches were deformably registered, and landmarks were projected onto the second image. 5) Landmark pair locations were refined manually or with an automated process. This workflow resulted in 1895 total landmark pairs, or 63 per case on average. Estimates of the landmark pair accuracy using digital phantoms were 0.7+/-1.2mm. The data is published in Zenodo at https://doi.org/10.5281/zenodo.14362785. Instructions for use can be found at https://github.com/deshanyang/Abdominal-DIR-QA. This dataset is a first-of-its-kind for abdominal DIR validation. The number, accuracy, and distribution of landmark pairs will allow for robust validation of DIR algorithms with precision beyond what is currently available.

cs.CV

Small metal artifact detection and inpainting in cardiac CT images

Background: Quantification of cardiac motion on pre-treatment CT imaging for stereotactic arrhythmia radiotherapy patients is difficult due to the presence of image artifacts caused by metal leads of implantable cardioverter-defibrillators (ICDs). New methods are needed to accurately reduce the metal artifacts in already reconstructed CTs to recover the otherwise lost anatomical information. Purpose: To develop a methodology to automatically detect metal artifacts in cardiac CT scans and inpaint the affected volume with anatomically consistent structures and values. Methods: ECG-gated 4DCT scans of 12 patients who underwent cardiac radiation therapy for treating ventricular tachycardia were collected. The metal artifacts in the images were manually contoured. A 2D U-Net deep learning (DL) model was developed to segment the metal artifacts. A dataset of synthetic CTs was prepared by adding metal artifacts from the patient images to artifact-free CTs. A 3D image inpainting DL model was trained to refill the metal artifact portion in the synthetic images with realistic values. The inpainting model was evaluated by analyzing the automated segmentation results of the four heart chambers on the synthetic dataset. Additionally, the raw cardiac patient cases were qualitatively inspected. Results: The artifact detection model produced a Dice score of 0.958 +- 0.008. The inpainting model was able to recreate images with a structural similarity index of 0.988 +- 0.012. With the chamber segmentations improved surface Dice scores from 0.684 +- 0.247 to 0.964 +- 0.067 and the Hausdorff distance reduced from 3.4 +- 3.9 mm to 0.7 +- 0.7 mm. The inpainting model's use on cardiac patient CTs was visually inspected and the artifact-inpainted images were visually plausible. Conclusion: We successfully developed two deep models to detect and inpaint metal artifacts in cardiac CT images.

physics.med-ph

A comprehensive liver CT landmark pair dataset for evaluating deformable image registration algorithms

Purpose: Evaluating deformable image registration (DIR) algorithms is vital for enhancing algorithm performance and gaining clinical acceptance. However, there's a notable lack of dependable DIR benchmark datasets for assessing DIR performance except for lung images. To address this gap, we aim to introduce our comprehensive liver computed tomography (CT) DIR landmark dataset library. Acquisition and Validation Methods: Thirty CT liver image pairs were acquired from several publicly available image archives as well as authors' institutions under institutional review board approval. The images were processed with a semi-automatic procedure to generate landmark pairs: 1) for each case, liver vessels were automatically segmented on one image; 2) landmarks were automatically detected at vessel bifurcations; 3) corresponding landmarks in the second image were placed using the deformable image registration method; 4) manual validation was applied to reject outliers and confirm the landmarks' positional accuracy. This workflow resulted in an average of ~68 landmark pairs per image pair, in a total of 2028 landmarks for all 30 cases. The general landmarking accuracy of this procedure was evaluated using digital phantoms. Estimates of the mean and standard deviation of landmark pair target registration errors (TRE) on digital phantoms were 0.64 and 0.40 mm. 99% of landmark pairs had TREs below 2 mm. Data Format and Usage Notes: All data are publicly available at Zenodo. Instructions for using our data and MATLAB code can be found on our GitHub page. Potential Applications: The landmark dataset generated in this work is the first collection of large-scale liver CT DIR landmarks prepared on real patient images. This dataset can provide researchers with a dense set of ground truth benchmarks for the quantitative evaluation of DIR algorithms within the liver.

physics.med-ph

Large-Language-Model Empowered Dose Volume Histogram Prediction for Intensity Modulated Radiotherapy

Treatment planning is currently a patient specific, time-consuming, and resource demanding task in radiotherapy. Dose-volume histogram (DVH) prediction plays a critical role in automating this process. The geometric relationship between DVHs in radiotherapy plans and organs-at-risk (OAR) and planning target volume (PTV) has been well established. This study explores the potential of deep learning models for predicting DVHs using images and subsequent human intervention facilitated by a large-language model (LLM) to enhance the planning quality. We propose a pipeline to convert unstructured images to a structured graph consisting of image-patch nodes and dose nodes. A novel Dose Graph Neural Network (DoseGNN) model is developed for predicting DVHs from the structured graph. The proposed DoseGNN is enhanced with the LLM to encode massive knowledge from prescriptions and interactive instructions from clinicians. In this study, we introduced an online human-AI collaboration (OHAC) system as a practical implementation of the concept proposed for the automation of intensity-modulated radiotherapy (IMRT) planning. In comparison to the widely-employed DL models used in radiotherapy, DoseGNN achieved mean square errors that were 80$\%$, 76$\%$ and 41.0$\%$ of those predicted by Swin U-Net Transformer, 3D U-Net CNN and vanilla MLP, respectively. Moreover, the LLM-empowered DoseGNN model facilitates seamless adjustment to treatment plans through interaction with clinicians using natural language.

cs.AI

A quality assurance framework for real-time monitoring of deep learning segmentation models in radiotherapy

To safely deploy deep learning models in the clinic, a quality assurance framework is needed for routine or continuous monitoring of input-domain shift and the models' performance without ground truth contours. In this work, cardiac substructure segmentation was used as an example task to establish a QA framework. A benchmark dataset consisting of Computed Tomography (CT) images along with manual cardiac delineations of 241 patients were collected, including one 'common' image domain and five 'uncommon' domains. Segmentation models were tested on the benchmark dataset for an initial evaluation of model capacity and limitations. An image domain shift detector was developed by utilizing a trained Denoising autoencoder (DAE) and two hand-engineered features. Another Variational Autoencoder (VAE) was also trained to estimate the shape quality of the auto-segmentation results. Using the extracted features from the image/segmentation pair as inputs, a regression model was trained to predict the per-patient segmentation accuracy, measured by Dice coefficient similarity (DSC). The framework was tested across 19 segmentation models to evaluate the generalizability of the entire framework. As results, the predicted DSC of regression models achieved a mean absolute error (MAE) ranging from 0.036 to 0.046 with an averaged MAE of 0.041. When tested on the benchmark dataset, the performances of all segmentation models were not significantly affected by scanning parameters: FOV, slice thickness and reconstructions kernels. For input images with Poisson noise, CNN-based segmentation models demonstrated a decreased DSC ranging from 0.07 to 0.41, while the transformer-based model was not significantly affected.

eess.IV