Searcharxiv⌕ Search

arXiv subjects

Yi Tao

Publications and source records attributed to Yi Tao.

52 records · Page 3Linked to original sources

Mode-resolved thermometry of trapped ion with Deep Learning

In trapped ion system, accurate thermometry of ion is crucial for evaluating the system state and precisely performing quantum operations. However, when the motional state of a single ion is far away from the ground state, the spatial dimension of the phonon state sharply increases, making it difficult to realize accurate and mode-resolved thermometry with existing methods. In this work, we apply deep learning for the first time to the thermometry of trapped ion, providing an efficient and mode-resolved method for accurately estimating large mean phonon numbers. Our trained neural network model can be directly applied to other experimental setups without retraining or post-processing, as long as the related parameters are covered by the model's effective range, and it can also be conveniently extended to other parameter ranges. We have conducted experimental verification based on our surface trap, of which the result has shown the accuracy and efficiency of the method for thermometry of single ion under large mean phonon number, and its mode resolution characteristic can make it better applied to the characterization of system parameters, such as evaluating cooling effectiveness, analyzing surface trap noise.

quant-ph↗

Search for Dark-Matter-Nucleon Interactions with a Dark Mediator in PandaX-4T

We report results of a search for dark-matter-nucleon interactions via a dark mediator using optimized low-energy data from the PandaX-4T liquid xenon experiment. With the ionization-signal-only data and utilizing the Migdal effect, we set the most stringent limits on the cross section for dark matter masses ranging from 30~$\rm{MeV/c^2}$ to 2~$\rm{GeV/c^2}$. Under the assumption that the dark mediator is a dark photon that decays into scalar dark matter pairs in the early Universe, we rule out significant parameter space of such thermal relic dark-matter model.

hep-ex↗

Noise-induced stochastic Nash equilibrium

In order to better understand the impact of environmental stochastic fluctuations on the evolution of animal behavior, we introduce the concept of a stochastic Nash equilibrium (SNE) that extends the classical concept of a Nash equilibrium (NE). Based on a stochastic stability analysis of a linear evolutionary game with temporally varying payoffs, we address the question of the existence of a SNE, either weak when the geometric mean payoff against it is the same for all other strategies or strong when it is strictly smaller for all other strategies, and its relationship with a stochastically evolutionarily stable (SES) strategy. While a strong SNE is always SES, this is not necessarily the case for a weak SNE. We give conditions for a completely mixed weak SNE not to be SES and to coexist with at least two strong SNE. More importantly, we show that a pair of two completely mixed strong SNE can emerge as the noise level increases. This not only indicates that a noise-induced SNE may possess some properties that a NE cannot possess, such as being completely mixed and strong, but also illustrates the complexity of evolutionary game dynamics in a stochastic environment.

q-bio.PE↗

Search for light dark matter from atmosphere in PandaX-4T

We report a search for light dark matter produced through the cascading decay of $η$ mesons, which are created as a result of inelastic collisions between cosmic rays and Earth's atmosphere. We introduce a new and general framework, publicly accessible, designed to address boosted dark matter specifically, with which a full and dedicated simulation including both elastic and quasi-elastic processes of Earth attenuation effect on the dark matter particles arriving at the detector is performed. In the PandaX-4T commissioning data of 0.63 tonne$\cdot$year exposure, no significant excess over background is observed. The first constraints on the interaction between light dark matter generated in the atmosphere and nucleus through a light scalar mediator are obtained. The lowest excluded cross-section is set at $5.9 \times 10^{-37}{\rm cm^2}$ for dark matter mass of $0.1$ MeV$/c^2$ and mediator mass of 300 MeV$/c^2$. The lowest upper limit of $η$ to dark matter decay branching ratio is $1.6 \times 10^{-7}$.

hep-ex↗

The First IEEE UV2022 Mathematical Modelling Competition: Backgrounds and Problems

Economic growth, people's health, and urban development face challenges in the post-epidemic era. How to promote high-quality and sustainable urban development, improve citizens' sense of happiness, and solve problems in city management have become a heated and crucial topic. Mathematical modeling is a research method that uses mathematical symbols to express practical problems, establish mathematical models, and then propose solutions. The 1$^{st}$ IEEE UV2022 Mathematical Modelling Competition is a satellite activity of the 6$^{th}$ IEEE International Conference on Universal Village, which expects participants to use mathematical modeling methods for practical problems and provide guidelines for sustainable social progress. This short paper introduces the background of the competition and publishes the problems to be solved.

cs.CY↗

A Search for Light Fermionic Dark Matter Absorption on Electrons in PandaX-4T

We report a search on a sub-MeV fermionic dark matter absorbed by electrons with an outgoing active neutrino using the 0.63 tonne-year exposure collected by PandaX-4T liquid xenon experiment. No significant signals are observed over the expected background. The data are interpreted into limits to the effective couplings between such dark matter and electrons. For axial-vector or vector interactions, our sensitivity is competitive in comparison to existing astrophysical bounds on the decay of such dark matter into photon final states. In particular, we present the first direct detection limits for an axial-vector (vector) interaction which are the strongest in the mass range from 25 to 45 (35 to 50) keV/c$^2$.

hep-ex↗

A First Search for Solar $^8$B Neutrino in the PandaX-4T Experiment using Neutrino-Nucleus Coherent Scattering

A search for interactions from solar $^8$B neutrinos elastically scattering off xenon nuclei using PandaX-4T commissioning data is reported. The energy threshold of this search is further lowered compared with the previous search for dark matter, with various techniques utilized to suppress the background that emerges from data with the lowered threshold. A blind analysis is performed on the data with an effective exposure of 0.48 tonne$\cdot$year, and no significant excess of events is observed. Among results obtained using the neutrino-nucleus coherent scattering, our results give the best constraint on the solar $^8$B neutrino flux. We further provide a more stringent limit on the cross section between dark matter and nucleon in the mass range from 3 to 9 GeV/c$^2$.

hep-ex↗

Measurement of Double Beta Decay Half-life of $^{136}$Xe with the PandaX-4T Detector

Precise measurement of two-neutrino double beta decay (DBD) half-life is an important step for the searches of Majorana neutrinos with neutrinoless double beta decay. We report the measurement of DBD half-life of $^{136}$Xe using the PandaX-4T dual-phase Time Projection Chamber (TPC) with 3.7-tonne natural xenon and the first 94.9-day physics data release. The background model in the fiducial volume is well constrained in situ by events in the outer active region. With a $^{136}$Xe exposure of 15.5 kg-year, we establish the half-life as $2.27 \pm 0.03 (stat.)\pm 0.10 (syst.)\times 10^{21}$ years. This is the first DBD half-life measurement with natural xenon and demonstrates the physics capability of a large-scale liquid xenon TPC in the field of rare event searches.

nucl-ex↗

First search for the absorption of fermionic dark matter with the PandaX-4T experiment

Compared with the signature of dark matter elastic scattering off nuclei, the absorption of fermionic dark matter by nuclei opens up a new searching channel for light dark matter with a characteristic monoenergetic signal. In this Letter, we explore the $95.0$-day data from the PandaX-4T commissioning run and report the first dedicated searching results of the fermionic dark matter absorption signal through a neutral current process. No significant signal was found, and the lowest limit on the dark matter-nucleon interaction cross section is set to be $1.5\times10^{-50}$ cm$^2$ for a fermionic dark matter mass of $40$ MeV/$c^2$ with 90\% confidence level.

hep-ex↗

Neutron-induced nuclear recoil background in the PandaX-4T experiment

Neutron-induced nuclear recoil background is critical to the dark matter searches in the PandaX-4T liquid xenon experiment. This paper studies the feature of neutron background in liquid xenon and evaluates their contribution in the single scattering nuclear recoil events through three methods. The first method is fully Monte Carlo simulation based. The last two are data-driven methods that also use the multiple scattering signals and high energy signals in the data, respectively. In the PandaX-4T commissioning data with an exposure of 0.63 tonne-year, all these methods give a consistent result that there are $1.15\pm0.57$ neutron-induced background in dark matter signal region within an approximated nuclear recoil energy window between 5 and 100 keV.

hep-ex↗

Evolutionary rationality of risk preference

Selection shapes all kinds of behaviors, including how we make decisions under uncertainty. The risk attitude reflected from it should be simple, flexible, yet consistent. In this paper we engaged evolutionary dynamics to find the decision making rule concerning risk that is evolutionarily superior, and developed the theory of evolutionary rationality. We highlight the importance of selection intensity and fitness, as well as their equivalents in the human mind, named as attention degree and meta-fitness, in the decision making process. Evolutionary rationality targets the maximization of the geometric mean of meta-fitness (or fitness), and attention degree (or selection intensity) holds the key in the change of attitude of the same individual towards different events and under varied situations. Then as an example, the Allais paradox is presented to show the application of evolutionary rationality, in which the anomalous choices made by the majority of people can be well justified by a simple change in the attention degree.

econ.TH↗

A search for two-component Majorana dark matter in a simplified model using the full exposure data of PandaX-II experiment

In the two-component Majorana dark matter model, one dark matter particle can scatter off the target nuclei, and turn into a slightly heavier component. In the framework of a simplified model with a vector boson mediator, both the tree-level and loop-level processes contribute to the signal in direct detection experiment. In this paper, we report the search results for such dark matter from PandaX-II experiment, using total data of the full 100.7 tonne$\cdot$day exposure. No significant excess is observed, so strong constraints on the combined parameter space of mediator mass and dark matter mass are derived. With the complementary search results from collider experiments, a large range of parameter space can be excluded.

hep-ex↗

Low Radioactive Material Screening and Background Control for the PandaX-4T Experiment

PandaX-4T is a ton-scale dark matter direct detection experiment using a dual-phase TPC technique at the China Jinping Underground Laboratory. Various ultra-low background technologies have been developed and applied to material screening for PandaX-4T, including HPGe gamma spectroscopy, ICP-MS, NAA, radon emanation measurement system, krypton assay station, and alpha detection system. Low background materials were selected to assemble the detector. Surface treatment procedures were investigated to further suppress radioactive background. Combining measured results and Monte Carlo simulation, the total material background rates of PandaX-4T in the energy region of 1-25 keV$\rm{}_{ee}$ are estimated to be (9.9 $\pm$ 1.9) $\times \ 10^{-3}$ mDRU for electron recoil and (2.8 $\pm$ 0.6) $\times \ 10^{-4}$ mDRU for nuclear recoil. In addition, $^{nat}$Kr in the detector is estimated to be <8 ppt.

physics.ins-det↗

A Search for the Cosmic Ray Boosted Sub-GeV Dark Matter at the PandaX-II Experiment

We report a novel search for the cosmic ray boosted dark matter using the 100~tonne$\cdot$day full data set of the PandaX-II detector located at the China Jinping Underground Laboratory. With the extra energy gained from the cosmic rays, sub-GeV dark matter particles can produce visible recoil signals in the detector. The diurnal modulations in rate and energy spectrum are utilized to further enhance the signal sensitivity. Our result excludes the dark matter-nucleon elastic scattering cross section between 10$^{-31}$cm$^{2}$ and 10$^{-28}$cm$^{2}$ for a dark matter masses from 0.1 MeV/$c^2$ to 0.1 GeV/$c^2$, with a large parameter space previously unexplored by experimental collaborations.

hep-ex↗

Dark Matter Search Results from the PandaX-4T Commissioning Run

We report the first dark matter search results using the commissioning data from PandaX-4T. Using a time projection chamber with 3.7-tonne of liquid xenon target and an exposure of 0.63 tonne$\cdot$year, 1058 candidate events are identified within an approximate nuclear recoil energy window between 5 and 100 keV. No significant excess over background is observed. Our data set a stringent limit to the dark matter-nucleon spin-independent interactions, with a lowest excluded cross section (90% C.L.) of $3.8\times10^{-47} $cm$^2$ at a dark matter mass of 30 GeV/$c^2$.

hep-ex↗

Light yield and field dependence measurement in PandaX-II dual-phase xenon detector

The dual-phase xenon time projection chamber (TPC) is one of the most sensitive detector technology for dark matter direct search, where the energy deposition of incoming particle can be converted into photons and electrons through xenon excitation and ionization. The detector response to signal energy deposition varies significantly with the electric field in liquid xenon. We study the detector's light yield and its dependence on the electric field in the PandaX-II dual-phase detector containing 580~kg liquid xenon in the sensitive volume. From our measurements, the light yield at electric fields from 0~V/cm to 317~V/cm is obtained for energy depositions up to 236~keV.

physics.ins-det↗