The Research and Development of New Electronics System and its Testing on the JNE-1ton Prototype Detector

The Jinping Neutrino Experiment (JNE), a next-generation neutrino observatory under construction at the China Jinping Underground Laboratory II (CJPL-II), requires high-precision waveform-based event reconstruction, imposing stringent demands on its readout electronics. To meet these requirements, we have developed a high-performance readout system featuring 1 GSa/s real-time sampling, 14-bit physical resolution with an effective number of bits (ENOB) of 10.6, a total data throughput of 64 Gbps, and a deterministic zero-delay clock distribution architecture. The new single-crate 64-channel system (PDS1500) was validated through bench tests and deployment on the upgraded JNE-1ton prototype detector. Its performance was further evaluated against a commercial reference system. The results demonstrate that all key metrics meet the JNE experimental requirements: zero data loss within a 1000 ns acquisition window, baseline noise reduced to one-third of the reference level, timing drift limited to 0.3 ns across power cycles, and an energy threshold as low as 0.1 MeV, enabling the detection of low-energy solar neutrinos. While the 14-bit physical resolution provides significantly higher waveform fidelity, the overall energy resolution in this test remains dominated by the intrinsic limitations of the JNE-1ton detector, as expected. Furthermore, the modular architecture provides the throughput and scalability required to support the full-scale 3000-channel JNE detector. These results collectively demonstrate that the newly developed electronics system fully satisfies the technical requirements of the future JNE experiment.

physics.ins-det

Combined Effects of Transient Ionizing and Electromagnetic Pulse on Vertical NPN Bipolar Transistor

Combined effects of transient ionizing and electromagnetic pulse on vertical NPN bipolar transistor were experimentally investigated under pulsed X-ray irradiation. Technology computer-aided design (TCAD) simulation method was also employed to explore the underlying physical mechanisms. The results demonstrate that the combined effect of a positive pulse injected into the collector (CEMP) and pulsed X-ray irradiation exceeds the linear superposition of their individual effects. Conversely, the combined effect of a positive pulse injected into the base (BEMP) and pulsed X-ray irradiation aligns closely with the results observed under BEMP acting alone. Mechanism analysis reveals that when CEMP and pulsed X-ray irradiation act simultaneously, there is a significant increase in both the drift photocurrent at the collector junction and the diffusion photocurrent near the collector junction. However, when BEMP and pulsed X-ray irradiation act simultaneously, these photocurrent components remain small, leading to a combined effect similar to the results observed when BEMP acts alone. These findings provide critical insights for the radiation-hardening design of bipolar circuits in harsh radiation environments.

physics.ins-det

Nonperiodic dynamic CT reconstruction using backward-warping INR with regularization of diffeomorphism (BIRD)

Dynamic computed tomography (CT) reconstruction faces significant challenges in addressing motion artifacts, particularly for nonperiodic rapid movements such as cardiac imaging with fast heart rates. Traditional methods struggle with the extreme limited-angle problems inherent in nonperiodic cases. Deep learning methods have improved performance but face generalization challenges. Recent implicit neural representation (INR) techniques show promise through self-supervised deep learning, but have critical limitations: computational inefficiency due to forward-warping modeling, difficulty balancing DVF complexity with anatomical plausibility, and challenges in preserving fine details without additional patient-specific pre-scans. This paper presents a novel INR-based framework, BIRD, for nonperiodic dynamic CT reconstruction. It addresses these challenges through four key contributions: (1) backward-warping deformation that enables direct computation of each dynamic voxel with significantly reduced computational cost, (2) diffeomorphism-based DVF regularization that ensures anatomically plausible deformations while maintaining representational capacity, (3) motion-compensated analytical reconstruction that enhances fine details without requiring additional pre-scans, and (4) dimensional-reduction design for efficient 4D coordinate encoding. Through various simulations and practical studies, including digital and physical phantoms and retrospective patient data, we demonstrate the effectiveness of our approach for nonperiodic dynamic CT reconstruction with enhanced details and reduced motion artifacts. The proposed framework enables more accurate dynamic CT reconstruction with potential clinical applications, such as one-beat cardiac reconstruction, cinematic image sequences for functional imaging, and motion artifact reduction in conventional CT scans.

cs.CV

Preliminary Design of Scalable Hardware Integrated Platform for LLRF Application

In this paper, the SHIP4LLRF (Scalable Hardware Integrated Platform for LLRF) based on 6U VPX-standard was designed preliminarily, which includes 6U mother board and two HPC FPGA mezzanine cards (FMCs). The ADC and DAC FMC is based on ADS54J60 from TI and LTC2000Y-16 form ADI, respectively. The system mother board is based on Xilinx Kintex UltraScale KU060, which also features 64-bit DDR4 SDRAM, QSFP and USB3.0 interfaces. Each FMC connector is assigned 58 pairs of LVDS standard IOs and 8 pairs of GTH high-speed serial lanes. Besides, the mother board is equipped with the self-developed ZYNQBee2 module based on ZYNQ7010 for slow control such as EPICS. All ADC or DAC raw data in each SHIP4LLEF is compressed loss-less without triggering and transmitted to the process board. A scalar quantization method which is in development is used for lossless compression of ADC raw data, the process board will decompress the ADC data and perform a digital algorithm to measure the amplitude and phase of the high frequency signal. This de-sign is scalable for testing and upgradability, mean-while, the trigger-less data transmission enable this system participate in both local (rack-scale) and accelerator-wide communication networks.

cs.AR

Optimal Design of Waveform Digitisers for Both Energy Resolution and Pulse Shape Discrimination

Fast digitisers and digital pulse processing have been widely used for spectral application and pulse shape discrimination (PSD) owing to their advantages in terms of compactness, higher trigger rates, offline analysis, etc. Meanwhile, the noise of readout electronics is usually trivial for organic, plastic, or liquid scintillator with PSD ability because of their poor intrinsic energy resolution. However, LaBr3(Ce) has been widely used for its excellent energy resolution and has been proven to have PSD ability for alpha/gamma particles. Therefore, designing a digital acquisition system for such scintillators as LaBr3(Ce) with both optimal energy resolution and promising PSD ability is worthwhile. Several experimental research studies about the choice of digitiser properties for liquid scintillators have already been conducted in terms of the sampling rate and vertical resolution. Quantitative analysis on the influence of waveform digitisers, that is, fast amplifier (optional), sampling rates, and vertical resolution, on both applications is still lacking. The present paper provides quantitative analysis of these factors and, hence, general rules about the optimal design of digitisers for both energy resolution and PSD application according to the noise analysis of time-variant gated charge integration.

physics.ins-det

Investigation of domain gap problem in several deep-learning-based CT metal artefact reduction methods

Metal artefacts in CT images may disrupt image quality and interfere with diagnosis. Recently many deep-learning-based CT metal artefact reduction (MAR) methods have been proposed. Current deep MAR methods may be troubled with domain gap problem, where methods trained on simulated data cannot perform well on practical data. In this work, we experimentally investigate two image-domain supervised methods, two dual-domain supervised methods and two image-domain unsupervised methods on a dental dataset and a torso dataset, to explore whether domain gap problem exists or is overcome. We find that I-DL-MAR and DudoNet are effective for practical data of the torso dataset, indicating the domain gap problem is solved. However, none of the investigated methods perform satisfactorily on practical data of the dental dataset. Based on the experimental results, we further analyze the causes of domain gap problem for each method and dataset, which may be beneficial for improving existing methods or designing new ones. The findings suggest that the domain gap problem in deep MAR methods remains to be addressed.

cs.CV

Insight-HXMT observations of jet-like corona in a black hole X-ray binary MAXI J1820+070

A black hole X-ray binary produces hard X-ray radiation from its corona and disk when the accreting matter heats up. During an outburst, the disk and corona co-evolves with each other. However, such an evolution is still unclear in both its geometry and dynamics. Here we report the unusual decrease of the reflection fraction in MAXI J1820+070, which is the ratio of the coronal intensity illuminating the disk to the coronal intensity reaching the observer, as the corona is observed to contrast during the decay phase. We postulate a jet-like corona model, in which the corona can be understood as a standing shock where the material flowing through. In this dynamical scenario, the decrease of the reflection fraction is a signature of the corona's bulk velocity. Our findings suggest that as the corona is observed to get closer to the black hole, the coronal material might be outflowing faster.

astro-ph.HE

Ionization-density-dependent Scintillation Pulse Shape and Mechanism of Luminescence Quenching in LaBr3:Ce

Pulse-shape discrimination (PSD) is usually achieved using the different fast and slow decay components of inorganic scintillators, such as BaF2, CsI:Tl, etc. However, LaBr3:Ce is considered to not possess different components at room temperature, but has been proved to have the capability of discriminating γ and α events using fast digitizers. In this paper, ionization-density-dependent transport and rate equations are used to quantitatively model the competing processes in a particle track. With one parameter set, the model reproduces the nonproportionality response of electrons or α particles, and explains the measured α and γ pulse-shape difference well. In particular, the nonlinear quenching of excited dopant ions, Ce3+, is confirmed herein to mainly contribute observable ionization α and γ pulse-shape differences. Further study of the luminescence quenching can also help to better understand the fundamental physics of nonlinear quenching and thus improve the crystal engineering. Moreover, based on the mechanism of dopant quenching, the ionization-density-dependent pulse-shape differences in other fast single-decay-component inorganic scintillators, such as lutetium yttrium oxyorthosilicate, Lu2(1-x)Y2xSiO5:Ce (LYSO) and CeBr3, are also predicted and verified with experiments.

physics.ins-det

Preliminary Design of a FADC Readout System for the Alpha/Beta Discrimination in a Large Area Plastic Scintillation Detector

This paper describes a FADC Readout system developed for the tap water $α/β$ dose monitoring system which is based on EJ444 phoswich scintillation detector and wavelength shifting fiber readout. The Readout system contains dual sampling channels that can supply sampling rate up to 1 GSPS, 14-Bit vertical resolution and adequate effective number of bits (9.7 Bits at 10 MHz), which is optimum for the discrimination of the minimal difference between alpha/beta signals. Moreover, the system is based on a ZYNQ SoC which provides high data throughput speed, low latency and excellent flexibility. As for the discrimination algorithms, a simple least-square classification method is used to discriminate the $α/β$ signals and shows high discrimination capability. Besides, the front-end electronics and high voltage supply modules are also briefly introduced in the paper.

physics.ins-det

Noise Analysis of Current Sensitive Preamplifiers and Influence on Energy Resolution of NaI:Tl Detector System

Current Sensitive Preamplifiers (CSPs) are widely used in front-end electronics in data acquire system (DAQ), due to their ability to amplify signals directly. The optimization of energy resolution requires CSPs with suitable parameters such as gain, bandwidth, and low noise, etc. With the rapid improvement of CSP's bandwidth and trans-impedance gain, it is necessary to know how does the output noise of CSPs effect the energy resolution. For this purpose, we built the noise model of CSPs and analyzed the output noise voltage density of CSPs based on different commercial operation amplifiers (OP AMPs). Theoretical and experimental results shown that OP AMPs with low input noise voltage density is superior than others on energy resolution. Moreover, noise normalization factor has been defined to verify the relationship between energy resolution and noise of CSPs. The experimental results shown that the energy resolution and noise normalization factor are linearly conformable. This paper can provide reference on selecting commercial OP AMPs to design CSPs for optimization of energy resolution.

physics.ins-det

Performance of Linear Classification Algorithms on alpha/gamma Discrimination for LaBr3:Ce Scintillation Detectors with Various Pulse Digitizer Properties

With the development of high-speed readout electronics, the digital pulse shape discrimination (PSD) methods have attracted the attention of more researchers, especially in the field of high energy physics and neutron detection. How to choose a PSD algorithm and corresponding data acquisition system (DAQ) naturally becomes a critical problem to settle down for the detection system designers. In this paper, the relationship between the classification performance of different PSD algorithms and digitizers' sampling properties (including sampling rate and the effective number of bits) has been researched based on $\mathrm{LaBr_3}$:Ce scintillation detectors. A self-developed integrated digitizer configured with five different ADCs and a WavePro 404HD oscilloscope were deployed to digitize the waveforms from $\mathrm{LaBr_3}$:Ce scintillators. Moreover, three PSD methods, charge comparison method (CCM), least square for classification method (LS) and Fisher's linear discriminant analysis (LDA), based on linear model were applied to discriminate the alpha signals from the intrinsic isotope $^{227}$Ac. With the LS method and a 125 MSPS 14-Bit ADC, the FoM value was 1.424$\pm$0.042, which is similar to the result from LDA but 31\% better than the result of CCM. The discrimination results showed that the performances of LS and LDA are less affected by the sampling rate with respect to the CCM method, which reflects in a better PSD capability. The results of this paper can help the developers of detector systems to make a trade-off among sampling properties, desirable discrimination results and the cost of systems.

physics.ins-det

A PXI-based Multi-channel Data Acquisition System for Fast Transient Pulses

In this paper, we design a PXI-based, multi-channel data-acquisition system (DAS) mainly applicable to recording one-shot fast transient pulses in nuclear physics experiments. The system consists of one NI PXIe-1085 chassis, containing a controller card and at most 16 data-acquisition (DAQ) cards. Every single DAQ card has a sampling rate of 1GS/s and a 12bit vertical resolution with the PXI interface and SFP+ transceiver for data transmission. When the system is put into operation near the pulsed radiation source, the SFP+ optical fiber channel enables a timely data transmission to a remote server. All of these cards in the chassis can be synchronized using PXI timing and triggering resources. Additionally, a simple DAS software is developed to display the pulsed signals captured and communicate with the host PC for remote control and data upload. After careful calibration, preliminary tests show that every DAQ channel achieves an analog bandwidth higher than 200MHz and an ENOB of more than 9 bits at a 1GS/s sampling rate. Owing to such high speed and resolution, the system may facilitate improvements in extracting maximum information from transient signals. Furthermore, with great scalability and high-speed data transmission, the system can be used for other nuclear physics experiments.

physics.ins-det

Optimization of Energy Resolution and Pulse Shape Discrimination for a CLYC Detector with Integrated Digitizers

Sufficient current pulse information of nuclear radiation detectors can be retained by direct waveform digitization owing to the improvement of digitizer's performance. In many circumstances, reasonable cost and power consumption are on demand while the energy resolution and PSD performance should be ensured simultaneously for detectors. This paper will quantitatively analyse the influence of vertical resolution and sampling rate of digitizers on the energy resolution and PSD performance. The energy resolution and PSD performance can be generally optimized by improving the sampling rate and ENOB (effective number of bits) of digitizers. Several integrated digitizers, with sampling rates varying from 100 MSPS to 500 MSPS and vertical resolution ranging from 12-Bit to 16-Bit, were designed and integrated with a CLYC detector for verifications. Experimental results show good accordance with theoretical calculations. The conclusion can give guidance to designs of digitizes for similar applications in need of optimizing the energy resolution and PSD performance, and help to choose proper digitizers for different requirements.

physics.ins-det

Insight-HXMT observations of Swift J0243.6+6124 during its 2017-2018 outburst

The recently discovered neutron star transient Swift J0243.6+6124 has been monitored by {\it the Hard X-ray Modulation Telescope} ({\it Insight-\rm HXMT). Based on the obtained data, we investigate the broadband spectrum of the source throughout the outburst. We estimate the broadband flux of the source and search for possible cyclotron line in the broadband spectrum. No evidence of line-like features is, however, found up to $\rm 150~keV$. In the absence of any cyclotron line in its energy spectrum, we estimate the magnetic field of the source based on the observed spin evolution of the neutron star by applying two accretion torque models. In both cases, we get consistent results with $B\rm \sim 10^{13}~G$, $D\rm \sim 6~kpc$ and peak luminosity of $\rm >10^{39}~erg~s^{-1}$ which makes the source the first Galactic ultraluminous X-ray source hosting a neutron star.

astro-ph.HE

single-electron events and 0νββ events in CdZnTe: A Monte Carlo simulation study

In neutrinoless double beta (0νββ) decay experiments, the diversity of topological signatures of different particles provides an important tool to distinguish double beta events from background events and reduce background rates. Aiming at suppressing the single-electron backgrounds which are most challenging, several groups have established Monte Carlo simulation packages to study the topological characteristics of single-electron events and 0νββ events and develop methods to differentiate them. In this paper, applying the knowledge of graph theory, a new topological signature called REF track (Refined Energy-Filtered track) is proposed and proven to be an accurate approximation of the real particle trajectory. Based on the analysis of the energy depositions along the REF track of single-electron events and 0νββ events, the REF energy deposition models for both events are proposed to indicate the significant differences between them. With these differences, this paper presents a new discrimination method, which, in the Monte Carlo simulation, achieved a single-electron rejection factor of 93.8+-0.3 (stat.)% as well as a 0νββ efficiency of 85.6+-0.4 (stat.)% with optimized parameters in CdZnTe.

physics.ins-det

Electron Track Reconstruction and Improved Modulation for Photoelectric X-ray Polarimetry

The key to photoelectric X-ray polarimetry is the determination of the emission direction of photoelectrons. Because of the low mass of an electron, the ionisation trajectory is not straight and the useful information needed for polarimetry is stored mostly in the initial part of the track where less energy is deposited. We present a new algorithm, based on the shortest path problem in graph theory, to reconstruct the 2D electron track from the measured image that is blurred due to transversal diffusion along drift and multiplication in the gas chamber. Compared with previous methods based on moment analysis, this algorithm allows us to identify the photoelectric interaction point more accurately and precisely for complicated tracks resulting from high energy photons or low pressure chambers. This leads to a better position resolution and a higher degree of modulation toward high energy X-rays. The new algorithm is justified using simulations and measurements with the gas pixel detector (GPD), and it should also work for other polarimetric techniques such as a time projection chamber (TPC). As the improvement is restricted in the high energy band, this new algorithm shows limited improvement for the sensitivity of GPD polarimeters, but it may have a larger potential for low-pressure TPC polarimeters.

physics.ins-det

Quantitative Analysis and Efficiency Study of PSD Methods for a LaBr3:Ce Detector

The LaBr3:Ce scintillator has been widely studied for nuclear spectroscopy because of its optimal energy resolution (<3%@ 662 keV) and time resolution (~300 ps). Despite these promising properties, the intrinsic radiation background of LaBr3:Ce is a critical issue, and pulse shape discrimination (PSD) has been shown to be an efficient potential method to suppress the alpha background from the 227Ac. In this paper, the charge comparison method (CCM) for alpha and gamma discrimination in LaBr3:Ce is quantitatively analysed and compared with two other typical PSD methods using digital pulse processing. The algorithm parameters and discrimination efficiency are calculated for each method. Moreover, for the CCM, the correlation between the CCM feature value distribution and the total charge (energy) is studied, and a fitting equation for the correlation is inferred and experimentally verified. Using the equations, an energy-dependent threshold can be chosen to optimize the discrimination efficiency. Additionally, the experimental results show a potential application in low-activity high-energy γ measurement by suppressing the alpha background.

physics.ins-det

A Transmissive X-ray Polarimeter Design For Hard X-ray Focusing Telescopes

The X-ray Timing and Polarization (XTP) is a mission concept for a future space borne X-ray observatory and is currently selected for early phase study. We present a new design of X-ray polarimeter based on the time projection gas chamber. The polarimeter, placed above the focal plane, has an additional rear window that allows hard X-rays to penetrate (a transmission of nearly 80% at 6 keV) through it and reach the detector on the focal plane. Such a design is to compensate the low detection efficiency of gas detectors, at a low cost of sensitivity, and can maximize the science return of multilayer hard X-ray telescopes without the risk of moving focal plane instruments. The sensitivity in terms of minimum detectable polarization, based on current instrument configuration, is expected to be 3% for a 1mCrab source given an observing time of 10^5 s. We present preliminary test results, including photoelectron tracks and modulation curves, using a test chamber and polarized X-ray sources in the lab.

astro-ph.IM