SearcharxivSearch

arXiv subjects

Yongjie Sun

Publications and source records attributed to Yongjie Sun.

18 recordsLinked to original sources

Performance of the Endcap Time-of-Flight detector in the STAR beam-energy scan

The STAR experiment at RHIC at Brookhaven National Laboratory completed the installation of an endcap time-of-flight subsystem (eTOF) in February 2019. The eTOF subsystem provided essential mid-rapidity particle identification (PID) for the fixed-target (FXT) portion of phase II of the beam energy scan (BES II). The FXT program allowed BES II to include center-of-mass energies from $\sqrt{s_{_{NN}}} = 3.0$ GeV to $\sqrt{s_{_{NN}}} = 7.7$ GeV, not accessible by colliding beams. The eTOF detectors and readout electronics were designed for the CBM experiment at FAIR and adapted for use at STAR. In this paper, we describe the details of the system in terms of geometrical layout, acceptance, calibration, hit reconstruction, and particle identification. The system achieved a time resolution of about 70 ps and a PID efficiency of about 70\%, meeting the design goals of the project.

physics.ins-det

Beyond Pipelines: A Survey of the Paradigm Shift toward Model-Native Agentic AI

The rapid evolution of agentic AI marks a new phase in artificial intelligence, where Large Language Models (LLMs) no longer merely respond but act, reason, and adapt. This survey traces the paradigm shift in building agentic AI: from Pipeline-based systems, where planning, tool use, and memory are orchestrated by external logic, to the emerging Model-native paradigm, where these capabilities are internalized within the model's parameters. We first position Reinforcement Learning (RL) as the algorithmic engine enabling this paradigm shift. By reframing learning from imitating static data to outcome-driven exploration, RL underpins a unified solution of LLM + RL + Task across language, vision and embodied domains. Building on this, the survey systematically reviews how each capability -- Planning, Tool use, and Memory -- has evolved from externally scripted modules to end-to-end learned behaviors. Furthermore, it examines how this paradigm shift has reshaped major agent applications, specifically the Deep Research agent emphasizing long-horizon reasoning and the GUI agent emphasizing embodied interaction. We conclude by discussing the continued internalization of agentic capabilities like Multi-agent collaboration and Reflection, alongside the evolving roles of the system and model layers in future agentic AI. Together, these developments outline a coherent trajectory toward model-native agentic AI as an integrated learning and interaction framework, marking the transition from constructing systems that apply intelligence to developing models that grow intelligence through experience.

cs.AI

Laser tuning parameters and concentration retrieval technique for wavelength modulation spectroscopy based on the variable-radius search artificial bee colony algorithm

A novel wavelength modulation spectroscopy (WMS) laser tuning parameters and concentration retrieval technique based on the variable-radius-search artificial bee colony(VRS-ABC) algorithm is proposed. The technique imitates the foraging behavior of bees to achieve the retrieval of gas concentration and laser tuning parameters in a calibration-free WMS system. To address the problem that the basic artificial bee colony(ABC) algorithm tends to converge prematurely, we improve the search method of the scout bee. In contrast to prior concentration retrieval methods that utilized the Levenberg-Marquardt algorithm, the current technique exhibits a reduced dependence on the pre-characterization of laser parameters, leading to heightened precision and reliability in concentration retrieval. We validated the simulation with the VRS-ABC-based technique and the LM-based technique for the target gas C2H2. The simulation results show that the VRS-ABC-based technique performs better in terms of convergence speed and fitting accuracy, especially in the multi-parameter model without exact characterization.

physics.ins-det

Principle and performance analysis of the Levenberg Marquardt algorithm in WMS spectral line fitting

Calibration free wavelength modulation spectroscopy (WMS) is an efficient technique for trace gas monitoring. It is widely used due to its resistance to light intensity fluctuations, strong suppression of low frequency noise, fast response time and excellent environmental adaptability. The calibration free WMS often employs the Levenberg Marquardt algorithm for spectral fitting to retrieve gas characteristics. However, to the best of our knowledge, an analysis of the main factors affecting the operational effectiveness of the Levenberg Marquardt algorithm in calibration free WMS has merely been reported. In this paper, we have systematically analyzed the Levenberg Marquardt algorithm s operating mechanism in WMS 2f/1f. The simulation results show that the number of parameters and initial parameter estimated errors are the main factors limiting the retrieval accuracy of the algorithm.

physics.ins-det

Concentration retrieval in a calibration-free wavelength modulation spectroscopy system using particle swarm optimization algorithm

This paper develops a spectral fitting technology based on the particle swarm optimization (PSO) algorithm, which is applied to a calibration-free wavelength modulation spectroscopy system to achieve concentration retrieval. As compared with other spectral fitting technology based on the Levenberg-Marquardt (LM) algorithm, this technology is relatively weakly dependent on the pre-characterization of the laser parameters. The gas concentration is calculated by fitting the simulated spectra to the measured spectra using the PSO algorithm. We validated the simulation with the LM algorithm and PSO algorithm for the target gas C2H2. The results showed that the convergence speed of the spectral fitting technique based on the PSO algorithm was about 63 times faster than the LM algorithm when the fitting accuracy remained the same. Within 5 seconds, the PSO algorithm can produce findings that are generally consistent with the values anticipated.

physics.ins-det

Simulation of the Signal Propagation for Thin-gap RPC in the ATLAS Phase-II Upgrade

Thin-gap Resistive Plate Chambers (RPCs) with a 1 mm gap size are introduced in the Phase-II ATLAS upgrade. Smaller avalanche charge due to the reduced gap size raises concerns for signal integrity. This work focuses on the RPC signal propagation process in lossless conditions, and an analytical study is implemented for the ATLAS RPC. Detector modeling is presented, and the simulation of the RPC signal is discussed in detail. Simulated characteristic impedance and crosstalk have been compared with the measured value to validate this model. This method is applied to different RPC design geometries, including the newly proposed $η-η$ readout scheme.

physics.ins-det

A Firefly Algorithm-based Spectral Fitting Technique for Wavelength Modulation Spectroscopy Systems

This paper proposes a novel calibration-free wavelength modulated spectroscopy (WMS) spectral fitting technique based on the firefly algorithm. The technique by simulating the information interaction behavior between fireflies to achieve the retrieval of gas concentration and laser parameters. Contrasted with the spectral fitting technique based on the classical Levenberg-Marquardt (LM) algorithm, the retrieval of gas concentrations by this technique is weakly dependent on the pre-characterization of the laser parameters. We select the P(13) absorption line of C2H2 at 1532.82 nm as the target spectra and compare the performance of two optimization method (LM and firefly) on gas concentration and laser parameters retrieval by simulation. The simulation results show that the spectral fitting technique based on the firefly algorithm performs better in terms of convergence speed and fitting accuracy, especially in the multi-parameter model without exact characterization.

physics.ins-det

Non-extensive statistical distributions of charmed meson production in Pb-Pb and pp($\overline{\text{p}}$) collisions

The mid-rapidity transverse-momentum spectra of charmed meson in Pb-Pb and pp($\overline{\text{p}}$) collisions are analyzed by Tsallis-Pareto distribution derived from non-extensive statistics. We perform uniform descriptions for both small and large systems over a wide range of collision energy and hadron transverse momentum. By establishing the relation between the event multiplicity and the Tsallis parameters, we observe that there is significant linearity between thermal temperature and Tsallis-q parameter in Pb-Pb collisions at $\sqrt{s_{NN}}$ = 2.76 TeV and 5.02 TeV. And the slope of the T $-$ (q - 1) parameter is positively correlated with the hadron mass. In addition, the charm mesons have higher thermal temperature than the light hadrons at the same q - 1, indicating that charmed flavor requires a higher temperature to achieve the same degree of non-extensive as light flavors in the heavy-ion collision. The same fit is performed to the transverse momentum spectra of charmed meson in pp($\overline{\text{p}}$) collision over a large energy range with Tsallis-Pareto distribution. It is found that the thermal temperature increases with system energy while the q parameter shows a saturated trend and stops at pp($\overline{\text{p}}$) limit, q - 1 = 0.142 $\pm$ 0.010. Meanwhile, the results of most peripheral Pb-Pb collisions are found to approach the pp($\overline{\text{p}}$) limit, which suggests that less medium effect and more in similarity with pp($\overline{\text{p}}$) collisions are found in more peripheral heavy-ion collisions.

hep-ex

A new layout about the graphite layers in RPC

The Resistive Plate Chamber (RPC) is widely used in experiments of high energy physics as trigger detector as its good time resolution and high efficiency. In the traditional layout of RPC, the graphite layers are indispensable parts. The working voltage is applied on these layers and the charge of avalanche dissipates through them. In this paper, a new design which removes the graphate layers is proposed to improve the structure of this detector. With this new design, the negative effect from the ununiformity of graphite is eliminated and the structure of detector is simplified.

physics.ins-det

Quality Assurance Test of Silicon Photomultipliers and Electronic Boards for STAR Event Plane Detector

The event plane detector (EPD), installed in the Solenoid Tracker at the Relativistic Heavy-Ion Collider located at the Brookhaven National Laboratory is a plastic scintillator-based device that measures the reaction centrality and event plane in the forward region of the relativistic heavy-ion collisions. We used silicon photomultiplier (SiPM) arrays to detect the photons produced in the scintillator via the fiber connection. Signals from the SiPM arrays were amplified by the front-end electronic (FEE) board, and sent to the analog-to-digital converter (ADC) boards for further processing via the receiver(RX) board. The full EPD system consisted of 24 super-sectors (SSs); each SS was equipped with two SiPM boards, two FEE boards and two RX boards, and they corresponded to 744 readout channels. All these boards were mass produced at the University of Science and Technology of China, with a dedicated quality assurance (QA) procedures applied to identify any problems before deployment. This article describes the details of the QA method and the related test system. The QA test results are presented along with the discussions.

physics.ins-det

Extensive beam test study of prototype MRPCs for the T0 detector at the CSR external-target experiment

The CSR External-target Experiment (CEE) will be the first large-scale nuclear physics experiment device at the Cooling Storage Ring (CSR) of the Heavy-Ion Research Facility in Lanzhou (HIRFL) in China. A new T0 detector has been proposed to measure the multiplicity, angular distribution and timing information of charged particles produced in heavy-ion collisions at the target region. Multi-gap resistive plate chamber (MRPC) technology was chosen as part of the construction of the T0 detector, which provides precision event collision times (T0) and collision geometry information. The prototype was tested with hadron and heavy-ion beams to study its performance. By comparing the experimental results with a Monte Carlo simulation, the time resolution of the MRPCs are found to be $\sim$ 50 ps or better. The timing performance of the T0 detector, including both detector and readout electronics, we found to fulfil the requirements of the CEE.

physics.ins-det

Multiplicity Dependence of Charged Particle, $ϕ$ Meson and Multi-strange Particle Productions in p+p Collisions at $\sqrt{\rm s}$ = 200 GeV with PYTHIA Simulation

We report the multiplicity dependence of charged particle productions for $π^{\pm}$, $K^{\pm}$, $p$, $\overline{p}$ and $ϕ$ meson at $|y| < 1.0$ in p+p collisions at $\sqrt{\rm s}$ = 200 GeV with $\rm PYTHIA$ simulation. The impact of parton multiple interactions and gluon contributions is studied and found to be possible sources of the particle yields splitting as a function of $p_T$ with respect to multiplicity. No obvious particle species dependence for the splitting is observed. The multiplicity dependence on ratios of $K^-/π^-$, $K^+/π^+$, $\overline{p}/π^-$, $p/π^+$ and $Λ/K^{0}_{s}$ in mid-rapidity in p+p collisions is found following the similar tendency as that in Au+Au collisions at $\sqrt{s_{NN}}$ = 200 GeV from RHIC, which heralds the similar underlying initial production mechanisms despite the differences in the initial colliding systems.

hep-ph

First results of the new endcap TOF commissioning at BESIII

The upgrade of the current BESIII Endcap TOF (ETOF) is carried out with the Multi-gap Resistive Plate Chamber (MRPC) technology. The installation of the new ETOF has been finished in October 2015. The first results of the MRPCs commissioning at BESIII are reported in this paper.

physics.ins-det

The upgrade system of BESIII ETOF with MRPC technology

The Beijing Spectrometer III (BESIII) endcap Time-Of-Filght (ETOF) was proposed to upgrade with Multigap Resistive Plate Chamber (MRPC) technology to substitute the current ETOF of scintillator+PMT for extending time resolutin better than 80 ps and enhance the particle identification capability to satisfy the higher precision requirement of physics. The ETOF system including MRPC modules, front end electronics (FEE), CLOCK module, fast control boards and time to digital modules (TDIG), has been designed, constructed and done some experimental tests seperately. Aiming at examining the quality of entire ETOF system and training the operation of all participated parts, a cosmic ray test system was built at the laboratory and underwent about three months to guarantee performance. In this paper the results will be presented indicating that the entire ETOF system works well and satisfies the requirements of the upgrade.

physics.ins-det

The cosmic ray test of MRPCs for the BESIII ETOF upgrade

In order to improve the particle identification capability of the Beijing Spectrometer III (BESIII),t is proposed to upgrade the current endcap time-of-flight (ETOF) detector with multi-gap resistive plate chamber (MRPC) technology. Aiming at extending ETOF overall time resolution better than 100ps, the whole system including MRPC detectors, new-designed Front End Electronics (FEE), CLOCK module, fast control boards and time to digital modules (TDIG), was built up and operated online 3 months under the cosmic ray. The main purposes of cosmic ray test are checking the detectors' construction quality, testing the joint operation of all instruments and guaranteeing the performance of the system. The results imply MRPC time resolution better than 100$ps$, efficiency is about 98$\%$ and the noise rate of strip is lower than 1$Hz/$($scm^{2}$) at normal threshold range, the details are discussed and analyzed specifically in this paper. The test indicates that the whole ETOF system would work well and satisfy the requirements of upgrade.

physics.ins-det

A Cosmic Ray Test Platform Based on the High Time Resolution MRPC Technology

In order to test the performance of detector/prototype in environment of laboratory, we design and build a larger area ($90\times52$ $cm^2$) test platform of cosmic ray based on well-designed Multi-gap Resistive Plate Chamber (MRPC) with an excellent time resolution and a high detection efficiency for the minimum ionizing particles (MIPs). The time resolution of the MRPC module used is tested to be ~80 ps, and the position resolution along the strip is ~5 mm, while the position resolution perpendicular to the strip is ~12.7 mm. The platform constructed by four MRPC modules can be functional for tracking the cosmic rays with a spatial resolution ~6.3 mm, and provide a reference time ~40 ps.

physics.ins-det

A Large area GEM Detector Using an improved Self-stretch Technique

A GEM detector with an effective area of 30*30 cm2 has been constructed using an improved self-stretch technique, which enables an easy and fast GEM assembling. The design and assembling of the detector is described. Results from tests of the detector with 8 keV X-rays on effective gain and energy resolution are presented.

physics.ins-det

A GEANT4 Simulation Studyof BESIII endcap TOF Upgrade

A GEANT4-based Monte-Carlo model is developed to study the performance of Endcap Time-Of-Flight (ETOF) at BESIII. It's found that the multiple scattering effects, mainly from the materials at the MDC endcap, can cause multi-hit on the ETOF's readout cell and significantly influence the timing property of ETOF. Multi-gap Resistive Plate Chamber (MRPC) with a smaller readout cell structure is more suitable for ETOF detector due to significantly reduced multi-hit rate, from 71.5% for currently-used scintillator-based ETOF to 21.8% or 16.7% for MRPC-based ETOF, depending on the readout pad size used. The timing performance of a MRPC ETOF is also improved. These simulation results suggest and guide an ETOF upgrade effort at BESIII.

physics.ins-det