SearcharxivSearch

arXiv subjects

Yoshio Kamiya

Publications and source records attributed to Yoshio Kamiya.

7 recordsLinked to original sources

Assessment of the Imaging Performance of the CITIUS High-Resolution Detector for Heavy Charged Particles and Neutrons

We report on the assessment of the imaging performance of CITIUS -- a high-speed X-ray detector developed for the large-scale synchrotron radiation facility SPring-8-II -- for heavy charged particles and neutrons. To characterize the detector response, an irradiation experiment was performed using alpha particles from an $^{241}$Am source at four back-bias voltages of 400V, 300 V, 200 V, and 170 V, thereby controlling the amount of charge diffusion. A Geant4 model of the experiment was constructed, and four model parameters were determined by template fitting to the measured signal cluster shape distributions. The best-fit values are: an intrinsic energy spread of 5% for the source, a gold fraction of 0.4 for the Au-Pd coating, a lateral charge diffusion spread of 26.5 ${\mu}$m over a drift distance of 650 ${\mu}$m at 400V back-bias, and a per-pixel readout noise of 10000 $e^{-}$ in the medium-gain channel. Using the obtained sensor model, simulations were performed for 4 MeV alpha particles and cold neutrons to evaluate the expected spatial resolution. In both cases, simulated CITIUS, when operated in a gain-selecting mode between high and medium gains, yields a substantial improvement: at a pixel size of 70 ${\mu}$m for example, the resolution improves from 9.1 ${\mu}$m to 1.2 ${\mu}$m for alpha particles, and from 26 ${\mu}$m to 1.9 ${\mu}$m for cold neutrons. These results suggest that two key features of CITIUS -- its gain-selecting architecture and the substantial charge sharing enabled by the long carrier drift distance -- extend its imaging capabilities beyond X-rays to heavy charged particles and neutrons.

physics.ins-det

Development of a Neutron Imager using CMOS Pixelated Sensor

We acquired an image of the Siemens Star Chart using the 10B-INTPIX4 CMOS pixelated imager at J-PARC MLF BL21 (NOVA). The image blurriness, characterized by a root mean square (rms) value of 17 um in the line spread function, corresponds to an rms beam divergence of 2.7 mrad. for the neutron beam. This is equivalent to the effective geometrical ratio (L/D ratio) of 370. The contrast of the image was analyzed as a function of structural scale of the chart, and based on this contrast, the modulation transfer function (MTF) of the imaging system was evaluated. The results indicate that the structure corresponding to the 50% cutoff is 12 line-space pairs per mm.

physics.ins-det

Robustness of a SiECAL used in Particle Flow Reconstruction

The physics program of future lepton colliders such as the ILC, will benefit from a jet energy resolution in the range 3-4%. The International Large Detector (ILD) reaches this goal over a large range of jet energies. In this paper, we report on the dependence of the simulated ILD performance on various parameters of its silicon-tungsten ECAL. We investigate the effects of dead areas in the silicon sensors, the thickness of the PCB at the heart of the detector, and the robustness of its performance with respect to dead channels, noise, mis-calibration and cross-talk.

physics.ins-det

A study of silicon sensor for ILD ECAL

The International Large Detector (ILD) is a proposed detector for the International Linear Collider (ILC). It has been designed to achieve an excellent jet energy resolution by using Particle Flow Algorithms (PFA), which rely on the ability to separate nearby particles within jets. PFA requires calorimeters with high granularity. The ILD Electromagnetic Calorimeter (ECAL) is a sampling calorimeter with thirty tungsten absorber layers. The total thickness of this ECAL is about 24 X$_0$, and it has between 10 and 100 million channels to make high granularity. Silicon sensors are a candidate technology for the sensitive layers of this ECAL. Present prototypes of these sensors have 256 5.5$\times$5.5 mm$^2$ pixels in an area of 9$\times$9 cm$^2$.We have measured various properties of these prototype sensors: the leakage current, capacitance, and full depletion voltage. We have also examined the response to an infrared laser to understand the sensor's response at its edge and between pixel readout pads, as well the effect of different guard ring designs. In this paper, we show results from these measurements and discuss future works.

physics.ins-det

A Search for non-Newtonian force in a precision measurement of the scattering of slow neutrons in Xenon gas

An experimental search for non-newtonian, gravity-like force in a precision measurement of the scattering of slow neutrons in Xenon gas is proposed. A preliminary experiment with small statistics of 25 hours irradiation time was performed and the observed scattering distribution is consistent with the expectation with no additional forces. A 95% CL limit on the coupling strength for a hypothetical force of 1 nm interaction range was evaluated to be 2*10^-15. The expected sensitivity for a planned high statistics runs is discussed.

hep-ex

Shintake Monitor in ATF2 : Present Status

A beam size monitor so called Shintake monitor, which uses the inverse Compton scattering between the laser interference fringe and the electron beam was designed for and installed at ATF2. The commissioning at ATF2 was started in the end of 2008 and succeeded in the measurement of the fringe pattern from the scattered gamma-rays. The present status of the Shintake monitor is described here.

physics.ins-det

Design of a Nanometer Beam Size Monitor for ATF2

We developed an electron beam size monitor for extremely small beam sizes. It uses a laser interference fringe for a scattering target with the electron beam. Our target performance is < 2 nm systematic error for 37 nm beam size and < 10% statistical error in a measurement using 90 electron bunches for 25 - 6000 nm beam size. A precise laser interference fringe control system using an active feedback function is incorporated to the monitor to achieve the target performance. We describe an overall design, implementations, and performance estimations of the monitor.

physics.ins-det