SearcharxivSearch

arXiv · 2603.29294

Assessment of the Imaging Performance of the CITIUS High-Resolution Detector for Heavy Charged Particles and Neutrons

Abstract

We report on the assessment of the imaging performance of CITIUS -- a high-speed X-ray detector developed for the large-scale synchrotron radiation facility SPring-8-II -- for heavy charged particles and neutrons. To characterize the detector response, an irradiation experiment was performed using alpha particles from an $^{241}$Am source at four back-bias voltages of 400V, 300 V, 200 V, and 170 V, thereby controlling the amount of charge diffusion. A Geant4 model of the experiment was constructed, and four model parameters were determined by template fitting to the measured signal cluster shape distributions. The best-fit values are: an intrinsic energy spread of 5% for the source, a gold fraction of 0.4 for the Au-Pd coating, a lateral charge diffusion spread of 26.5 ${\mu}$m over a drift distance of 650 ${\mu}$m at 400V back-bias, and a per-pixel readout noise of 10000 $e^{-}$ in the medium-gain channel. Using the obtained sensor model, simulations were performed for 4 MeV alpha particles and cold neutrons to evaluate the expected spatial resolution. In both cases, simulated CITIUS, when operated in a gain-selecting mode between high and medium gains, yields a substantial improvement: at a pixel size of 70 ${\mu}$m for example, the resolution improves from 9.1 ${\mu}$m to 1.2 ${\mu}$m for alpha particles, and from 26 ${\mu}$m to 1.9 ${\mu}$m for cold neutrons. These results suggest that two key features of CITIUS -- its gain-selecting architecture and the substantial charge sharing enabled by the long carrier drift distance -- extend its imaging capabilities beyond X-rays to heavy charged particles and neutrons.

Explore related subjects

Keep this discovery

BibTeXRIS

Yoshio Kamiya, Haruki Nishino, Takaki Hatsui. 2026-03-31. Assessment of the Imaging Performance of the CITIUS High-Resolution Detector for Heavy Charged Particles and Neutrons. https://doi.org/10.1016/j.nima.2026.171677

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det