Searcharxiv⌕ Search

arXiv subjects

Youssef S. Hassan

Publications and source records attributed to Youssef S. Hassan.

9 recordsLinked to original sources

Atomic clock frequency ratios with fractional uncertainty $\leq 3.2 \times 10^{-18}$

We report high-precision frequency ratio measurements between optical atomic clocks based on $^{27}$Al$^+$, $^{171}$Yb, and $^{87}$Sr. With total fractional uncertainties at or below $3.2 \times 10^{-18}$, these measurements meet an important milestone criterion for redefinition of the second in the International System of Units. Discrepancies in $^{87}$Sr ratios at approximately $1\times10^{-16}$ and the Al$^+$/Yb ratio at $1.6\times10^{-17}$ in fractional units compared to our previous measurements underscore the importance of repeated, high-precision comparisons by different laboratories. A key innovation in this work is the use of a common ultrastable reference delivered to all clocks via a 3.6 km phase-stabilized fiber link between two institutions. Derived from a cryogenic single-crystal silicon cavity, this reference improves comparison stability by a factor of 2 to 3 over previous systems, with an optical lattice clock ratio achieving a fractional instability of $1.3 \times 10^{-16}$ at 1 second. By enabling faster comparisons, this stability will improve sensitivity to non-white noise processes and other underlying limits of state-of-the-art optical frequency standards.

physics.atom-ph↗

Cryogenic Optical Lattice Clock with $1.7\times 10^{-20}$ Blackbody Radiation Stark Uncertainty

Controlling the Stark perturbation from ambient thermal radiation is key to advancing the performance of many atomic frequency standards, including state-of-the-art optical lattice clocks (OLCs). We demonstrate a cryogenic OLC that utilizes a dynamically actuated radiation shield to control the perturbation at $1.7\times10^{-20}$ fractional frequency, a factor of $\sim$40 beyond the best OLC to date. Our shield furnishes the atoms with a near-ideal cryogenic blackbody radiation (BBR) environment by rejecting external thermal radiation at the part-per-million level during clock spectroscopy, overcoming a key limitation with previous cryogenic BBR control solutions in OLCs. While the lowest BBR shift uncertainty is realized with cryogenic operation, we further exploit the radiation control that the shield offers over a wide range of temperatures to directly measure and verify the leading BBR Stark dynamic correction coefficient for ytterbium. This independent measurement reduces the literature-combined uncertainty of this coefficient by 30%, thus benefiting state-of-the-art Yb OLCs operated at room temperature. We verify the static BBR coefficient for Yb at the low $10^{-18}$ level.

physics.atom-ph↗

Lattice Light Shift Evaluations In a Dual-Ensemble Yb Optical Lattice Clock

In state-of-the-art optical lattice clocks, beyond-electric-dipole polarizability terms lead to a break-down of magic wavelength trapping. In this Letter, we report a novel approach to evaluate lattice light shifts, specifically addressing recent discrepancies in the atomic multipolarizability term between experimental techniques and theoretical calculations. We combine imaging and multi-ensemble techniques to evaluate lattice light shift atomic coefficients, leveraging comparisons in a dual-ensemble lattice clock to rapidly evaluate differential frequency shifts. Further, we demonstrate application of a running wave field to probe both the multipolarizability and hyperpolarizability coefficients, establishing a new technique for future lattice light shift evaluations.

physics.atom-ph↗

Clock-line-mediated Sisyphus Cooling

We demonstrate sub-recoil Sisyphus cooling using the long-lived $^{3}\mathrm{P}_{0}$ clock state in alkaline-earth-like ytterbium. A 1388 nm optical standing wave nearly resonant with the $^{3}\textrm{P}_{0}$$\,\rightarrow$$\,^{3}\textrm{D}_{1}$ transition creates a spatially periodic light shift of the $^{3}\textrm{P}_{0}$ clock state. Following excitation on the ultranarrow clock transition, we observe Sisyphus cooling in this potential, as the light shift is correlated with excitation to $^{3}\textrm{D}_{1}$ and subsequent spontaneous decay to the $^{1}\textrm{S}_{0}$ ground state. We observe that cooling enhances the loading efficiency of atoms into a 759 nm magic-wavelength one-dimensional (1D) optical lattice, as compared to standard Doppler cooling on the $^{1}\textrm{S}_{0}$$\,\rightarrow\,$$^{3}\textrm{P}_{1}$ transition. Sisyphus cooling yields temperatures below 200 nK in the weakly confined, transverse dimensions of the 1D optical lattice. These lower temperatures improve optical lattice clocks by facilitating the use of shallow lattices with reduced light shifts, while retaining large atom numbers to reduce the quantum projection noise. This Sisyphus cooling can be pulsed or continuous and is applicable to a range of quantum metrology applications.

physics.atom-ph↗

Ratchet Loading and Multi-Ensemble Operation in an Optical Lattice Clock

We demonstrate programmable control over the spatial distribution of ultra-cold atoms confined in an optical lattice. The control is facilitated through a combination of spatial manipulation of the magneto-optical trap and atomic population shelving to a metastable state. We first employ the technique to load an extended (5 mm) atomic sample with uniform density in an optical lattice clock, reducing atomic interactions and realizing remarkable frequency homogeneity across the atomic cloud. We also prepare multiple spatially separated atomic ensembles and realize multi-ensemble clock operation within the standard one-dimensional (1D) optical lattice clock architecture. Leveraging this technique, we prepare two oppositely spin-polarized ensembles that are independently addressable, offering a platform for implementing spectroscopic protocols for enhanced tracking of local oscillator phase. Finally, we demonstrate a relative fractional frequency instability at one second of $2.4(1) \times10^{-17}$ between two ensembles, useful for characterization of intra-lattice differential systematics.

physics.atom-ph↗

Optical coherence between atomic species at the second scale: improved clock comparisons via differential spectroscopy

Comparisons of high-accuracy optical atomic clocks \cite{Ludlow2015} are essential for precision tests of fundamental physics \cite{Safronova2018}, relativistic geodesy \cite{McGrew2018, Grotti2018, Delva2019}, and the anticipated redefinition of the SI second \cite{Riehle2018}. The scientific reach of these applications is restricted by the statistical precision of interspecies comparison measurements. The instability of individual clocks is limited by the finite coherence time of the optical local oscillator (OLO), which bounds the maximum atomic interrogation time. In this letter, we experimentally demonstrate differential spectroscopy \cite{Hume2016}, a comparison protocol that enables interrogating beyond the OLO coherence time. By phase-coherently linking a zero-dead-time (ZDT) \cite{Schioppo2017} Yb optical lattice clock with an Al$^+$ single-ion clock via an optical frequency comb and performing synchronised Ramsey spectroscopy, we show an improvement in comparison instability relative to our previous result \cite{network2020frequency} of nearly an order of magnitude. To our knowledge, this result represents the most stable interspecies clock comparison to date.

physics.atom-ph↗

Optical Atomic Clock Comparison through Turbulent Air

We use frequency comb-based optical two-way time-frequency transfer (O-TWTFT) to measure the optical frequency ratio of state-of-the-art ytterbium and strontium optical atomic clocks separated by a 1.5 km open-air link. Our free-space measurement is compared to a simultaneous measurement acquired via a noise-cancelled fiber link. Despite non-stationary, ps-level time-of-flight variations in the free-space link, ratio measurements obtained from the two links, averaged over 30.5 hours across six days, agree to $6\times10^{-19}$, showing that O-TWTFT can support free-space atomic clock comparisons below the $10^{-18}$ level.

physics.optics↗

Frequency Ratio Measurements with 18-digit Accuracy Using a Network of Optical Clocks

Atomic clocks occupy a unique position in measurement science, exhibiting higher accuracy than any other measurement standard and underpinning six out of seven base units in the SI system. By exploiting higher resonance frequencies, optical atomic clocks now achieve greater stability and lower frequency uncertainty than existing primary standards. Here, we report frequency ratios of the $^{27}$Al$^+$, $^{171}$Yb and $^{87}$Sr optical clocks in Boulder, Colorado, measured across an optical network spanned by both fiber and free-space links. These ratios have been evaluated with measurement uncertainties between $6\times10^{-18}$ and $8\times10^{-18}$, making them the most accurate reported measurements of frequency ratios to date. This represents a critical step towards redefinition of the SI second and future applications such as relativistic geodesy and tests of fundamental physics.

physics.atom-ph↗

Coherent Optical Clock Down-Conversion for Microwave Frequencies with 10-18 Instability

Optical atomic clocks are poised to redefine the SI second, thanks to stability and accuracy more than one hundred times better than the current microwave atomic clock standard. However, the best optical clocks have not seen their performance transferred to the electronic domain, where radar, navigation, communications, and fundamental research rely on less stable microwave sources. By comparing two independent optical-to-electronic signal generators, we demonstrate a 10 GHz microwave signal with phase that exactly tracks that of the optical clock phase from which it is derived, yielding an absolute fractional frequency instability of 1*10-18 in the electronic domain. Such faithful reproduction of the optical clock phase expands the opportunities for optical clocks both technologically and scientifically for time-dissemination, navigation, and long-baseline interferometric imaging.

physics.optics↗