SearcharxivSearch

arXiv subjects

Yuanbo Du

Publications and source records attributed to Yuanbo Du.

6 recordsLinked to original sources

Practical Lossless Volumetric Medical Image Compression via Tri-plane Context Tree Learning

Lossless compression of volumetric medical images is of paramount importance for clinical and research applications where data fidelity is essential. Traditional compression methods are often limited in efficiency due to rigid, handcrafted models. Conversely, deep neural network (DNN)-based compression methods, while effective, demand substantial computational resources, hindering deployment in resource-constrained settings. To address these challenges, we propose a novel tri-plane context tree (TCT)-based method for lossless volumetric medical image compression that delivers high performance without relying on DNNs or external training data. To exploit intra-slice and inter-slice redundancies, we introduce a compact tri-plane context representation that decomposes complex 3D context modeling into efficient 2D modeling on three orthogonal planes. By integrating this representation with a context tree framework, we develop an input-specific TCT model employing an adaptive binary tree structure. At each tree node, the model dynamically selects from a suite of tri-plane based predictors and contextual feature extractors, enabling data-adaptive context modeling tailored to local structural characteristics. Instead of offline training, we sample a subset of the input volume to learn the TCT model by optimizing the minimum description length (MDL) through iterative construction and pruning. With the learned TCT model, each pixel retrieves its corresponding context, computes the prediction residual using the predictor dictated by the context, and performs entropy encoding based on the associated histograms. Experimental results demonstrate that the proposed method achieves compression performance on par with recent DNN-based methods on multiple datasets, while maintaining low computational cost and fast coding speeds, making it highly applicable in practice.

eess.IV

Progress of the TianQin project

TianQin is a future space-based gravitational wave observatory targeting the frequency window of $10^{-4}$ Hz $\sim 1$ Hz. A large variety of gravitational wave sources are expected in this frequency band, including the merger of massive black hole binaries, the inspiral of extreme/intermediate mass ratio systems, stellar-mass black hole binaries, Galactic compact binaries, and so on. TianQin will consist of three Earth orbiting satellites on nearly identical orbits with orbital radii of about $10^5$ km. The satellites will form a normal triangle constellation whose plane is nearly perpendicular to the ecliptic plane. The TianQin project has been progressing smoothly following the ``0123" technology roadmap. In step ``0", the TianQin laser ranging station has been constructed and it has successfully ranged to all the five retro-reflectors on the Moon. In step ``1", the drag-free control technology has been tested and demonstrated using the TianQin-1 satellite. In step ``2", the inter-satellite laser interferometry technology will be tested using the pair of TianQin-2 satellites. The TianQin-2 mission has been officially approved and the satellites will be launched around 2026. In step ``3", i.e., the TianQin-3 mission, three identical satellites will be launched around 2035 to form the space-based gravitational wave detector, TianQin, and to start gravitational wave detection in space.

gr-qc

Development of a Cesium Fountain Clock at HUST: Preliminary Results

A cesium atomic fountain clock is under development at Huazhong University of Science and Technology (HUST) in China. In this paper, we describe the construction of the entire fountain clock system and report the preliminary results. A frequency stability of $2.5\times 10^{-13} τ^{-1/2}$ has been achieved by inter-comparison with a hydrogen maser, and the factors limiting the frequency stability are also discussed.

physics.atom-ph

A simple scheme of low phase noise microwave synthesizers based on the sub-sampling phase lock loop

In this paper, we demonstrate a simple scheme of 6.835 GHz microwave frequency synthesizer based on the sub-sampling phase lock loop (PLL) technique. The application of the sub-sampling PLL is the key to simplify the architecture of the synthesizer in this scheme. A 100 MHz oven controlled crystal oscillator (OCXO) with ultra-low phase noise is used as the initial signal source. Then a dielectric resonant oscillator (DRO) of 6.8 GHz is directly phase locked to the 100 MHz OCXO utilizing the sub-sampling PLL. Benefiting from the sub-sampling PLL, the processes of microwave frequency multiplication and phase lock which are necessary in the development of microwave synthesizer are greatly simplified. Therefore, the architecture of the synthesizer is very simple. Correspondingly, the power consumption and cost of the synthesizer are low. The absolute phase noises of the 6.835 GHz output signal are measured to be -47 dBc/Hz, -77 dBc/Hz, -104 dBc/Hz and -121 dBc/Hz at 1 Hz, 10 Hz, 100 Hz and 1 kHz offset frequencies, respectively. he synthesizer can be used as the local oscillator of the Rb atomic clocks. For the Rb atomic clocks operated in the continuous or pulsed optically pumped (POP) mode, Tthe short-term frequency stability limited by the absolute phase noises of the synthesizer through the intermodulation or the Dick effect is theoretically calculated to be better than 5.0E10^-14/t^1/2. This low phase noise microwave frequency synthesizer can be used in other experiments of fundamental physics measurement.

physics.atom-ph

A low phase noise microwave frequency synthesizer based on parameters optimized NLTL for Cs fountain clock

We report on the development and phase noise performance of a 9.1926 GHz microwave frequency synthesizer to be used as the local oscillator for a Cs fountain clock. It is based on frequency multiplication and synthesis from an ultralow phase noise 5 MHz Oven Controlled Crystal Oscillator (OCXO) and 100 MHz Voltage Controlled Crystal Oscillator (VCXO).The key component of the frequency multiplication is a non-linear transmission-line (NLTL) used as a frequency comb generator. The phase noise of the synthesizer is improved by carefully optimizing the input power, the input and output impedances of the NLTL. The absolute phase noises of the 9.1926 GHz output signal are measured to be -64 dBc/Hz, -83 dBc/Hz, -92 dBc/Hz, -117 dBc/Hz and -119 dBc/Hz at 1 Hz, 10Hz, 100Hz, 1 kHz and 10 kHz offset frequencies, respectively. The residual phase noise of the synthesizer is measured to be -82 dBc/Hz at 1 Hz offset frequency. The measurement result shows that the absolute phase noise at the frequency range of 1 - 100 Hz is mainly limited by the phase noise of the OCXO. The contribution of the absolute phase noise to the fountain clock short-term frequency stability is calculated to be 7.0x10^(-14). The residual frequency stability of the synthesizer is measured to be1.5x10^(-14), which is consistent with the calculated frequency stability due to the residual phase noise of the synthesizer. Meanwhile we designed and realized an interferometric microwave switch in the synthesizer to eliminate the frequency shifts induced by the microwave leakage. The extinction ratio of the switch is measured to be more than 50 dB. In the scheme, we use only commercially available components to build the microwave frequency synthesizer with excellent phase noise performance for high-performance Cs fountain clocks.

physics.atom-ph

Decreasing the uncertainty of atomic clocks via real-time noise distinguish

The environmental perturbation on atoms is the key factor restricting the performance of atomic frequency standards, especially in long term scale. In this letter, we demonstrate a real-time noise distinguish operation of atomic clocks. The operation improves the statistical uncertainty by about an order of magnitude of our fountain clock which is deteriorated previously by extra noises. The frequency offset bring by the extra noise is also corrected. The experiment proves the real-time noise distinguish operation can reduce the contribution of ambient noises and improve the uncertainty limit of atomic clocks.

physics.atom-ph