SearcharxivSearch

arXiv subjects

Yuanchun Liu

Publications and source records attributed to Yuanchun Liu.

14 recordsLinked to original sources

Search for neutrinoless quadruple beta decay of $^{136}$Xe in PandaX-4T detector

The observation of neutrinoless quadruple beta decay (0$\nu$4$\beta$) in the absence of neutrinoless double beta decay (0$\nu$2$\beta$) has been argued to provide a strong indication that neutrinos are Dirac particles. We report a search for 0$\nu$4$\beta$ decay of $^{136}\text{Xe}$ using a total $^{136}\text{Xe}$ exposure of 148.4 kg$\cdot$yr, collected during the commissioning and the first science runs of the PandaX-4T experiment. No significant excess of events over the background is observed. A lower limit on the 0$\nu$4$\beta$ decay half-life of $^{136}\text{Xe}$ is set at 6.01 x $10^{24}$ yr at the 90% confidence level. This result establishes the most stringent constraint on this process in xenon, demonstrating the unique capability of the PandaX-4T detector in probing lepton number violation and shedding light on the fundamental nature of neutrinos.

nucl-ex

Measurement of solar $pp$ neutrino flux with the new PandaX-4T data

We report a new measurement of the solar proton--proton ($pp$) neutrino flux via neutrino--electron elastic scattering using the PandaX-4T Run 2 data set collected between 2024 and 2026, corresponding to an exposure of 1.9 tonne$\cdot$yr. Before Run 2 data taking, the detector underwent a series of upgrades to improve its response and background conditions. Time variations of radioactive noble-gas impurities are constrained using the physics data themselves, complemented by measurements from the gas-assay system. The analysis introduced improvements in the data processing chain, detector response characterization, and background models. A blind spectral analysis was then performed on the electronic-recoil data across a wide energy range from 20 to 1000 keV. In combination with the Run 0 data published earlier, the fitted $pp$ flux is $(8.5 \pm 3.5)\times 10^{10}$ $\mathrm{cm^{-2}s^{-1}}$, consistent with the prediction of the Standard Solar Model. With a statistical significance of $2.2\sigma$ above background, this marks the first positive indication of solar $pp$ neutrino--electron scattering below an electronic-recoil energy of 165 keV.

hep-ex

A MIDAS-based Data Acquisition System for Gaseous Detectors

We present a data acquisition~(DAQ) software based on the MIDAS framework, specifically for gaseous detectors to support the detector deployments and applications. It implements a comprehensive suite of functions, including parameter configuration, data acquisition, decoding, and storage, alongside web-based operation and real-time monitoring capabilities. We establish a fully unified workflow spanning data acquisition to offline analysis, enabling real-time visualization of signal waveforms and energy spectra. The system has been successfully deployed in the PandaX-III experiment, which utilized a high-pressure gaseous detector to search for neutrinoless double beta decay. Its performance and stability have been validated through tests involving two distinct electronics setups and joint commissioning with the detector.

physics.ins-det

Comparative study of equilibrium and non-equilibrium predictions by different models for a hypersonic cone at high-altitude

Targeting a cone with the half-angle as 10-deg at M = 27 and H = 72 km, simulations were conducted comparatively to analyze the predictions by different equilibrium and non-equilibrium gas models. Following validation and grid studies, systematic comparisons on aerodynamic performance, flow structures, and characteristic distributions were performed. The key findings are: (1) While the overall flow structures are broadly similar, discrepancies exist in the features at the base locations, e.g., the diverse high-temperature distributions. Notably, the vibrational temperatures distribute differently under slip and non-slip boundary conditions near the wall; (2) The equilibrium gas model predicts higher drag coefficient, wall heat flux, and skin friction than those of non-equilibrium models. Predictions also vary among the non-equilibrium models themselves. Specifically, compared to the three-temperature model, the one- and two-temperature models predict larger drag coefficients with the relative difference exceeding 5%. Nevertheless, the results from the three-temperature model with and without slip conditions are largely consistent; (3) The disparities between equilibrium and non-equilibrium characteristics are primarily manifested in the shock layer and wake regions. Within these regions, the overall temperature for the equilibrium gas is lower than that for the non-equilibrium cases, while in the latter specific non-equilibrium features are distinctly exhibited, e.g., the translational-rotational temperature is generally higher than that from the one-temperature model, and the vibrational-electronic temperature shows the opposite trend. Notably, in the slip flow within the three-temperature model, the translational-rotational temperature is higher and, particularly, the vibrational temperature is even larger than counterparts of the non-slip flows near the wall and base center line.

physics.flu-dyn

Optimization of gain uniformity in thermal bonding Micromegas for the PandaX-III experiment

Micro-pattern gas detectors (MPGDs) are widely utilized in physics experiments owing to their excellent spatial resolution and high-rate capabilities. Within the PandaX-III experiment, which aims to investigate neutrinoless double beta decay, Micromegas detectors serve as charge readout devices. High energy resolution is a critical requirement for the readout plane in this context, and gain uniformity significantly impacts the achievable resolution, primarily because of the extended tracks of primary ionization electrons. However, scaling up MPGDs to larger active areas exacerbates the challenge of maintaining gain uniformity, and effectively controlling the uniformity of the avalanche gap is a key factor in the detector manufacturing process via the thermal bonding method. This study demonstrates that optimizing the thermal bonding films specifically at the detector edges can effectively improve the gain uniformity, achieving a gain uniformity of < 5% over the entire 200*200 mm2 active area in a 1 bar Ar/isobutane (96.5/3.5) gas mixture. Additionally, the gain uniformity of approximately 14% was characterized at high pressures of up to 10 bar, revealing promising potential for high resolution measurements in the PandaX-III experiment and other high-pressure applications.

physics.ins-det

Precise $^{136}$Xe Double Beta Decay Measurement in PandaX-4T with Implications on the Nuclear Matrix Elements and Majorons

The continuous spectrum of double beta decay ($\beta\beta$) provides a sensitive probe to test the predictions of the standard model and to search for signatures of new physics beyond it. We present a comprehensive analysis of the $^{136}$Xe $\beta\beta$ spectrum utilizing $39.1 \pm 0.7~\textrm{kg}\cdot\textrm{yr}$ of $^{136}$Xe exposure from the PandaX-4T experiment. The analysis yields the most precise measurement to date of the $^{136}$Xe two-neutrino double beta decay ($2\nu\beta\beta$) half-life, $(2.14 \pm 0.05) \times 10^{21}$ years, the uncertainty of which is reduced by a factor of 2 compared to our previous result. We measure the parameter $\xi_{31}^{2\nu}$, defined as the ratio between the subleading and leading components of the $^{136}$Xe $2\nu\beta\beta$ nuclear matrix element, to be $0.59^{+0.41}_{-0.38}$, which is consistent with theoretical predictions. We also search for Majoron-emitting modes of $^{136}$Xe $\beta\beta$, establishing the most stringent limit for the spectral index $n=7$.

nucl-ex

GPS-Synchronized Monitoring of Core-collapse Supernova Bursts with PandaX-4T via Coherent Elastic Neutrino Nuclear Scattering

The landmark detection of neutrinos from SN1987A marked the dawn of neutrino astrophysics. The neutrino burst provided essential insights into fundamental properties of neutrinos, and served as key probes of stellar evolution and supernova dynamics. The recent advancement in coherent elastic neutrino-nucleus scattering enables the detection of core-collapse supernova burst neutrinos using tonne-scale liquid xenon detectors originally designed for dark matter direct detection. Leveraging this capability, we developed and deployed an online supernova monitoring system for the PandaX-4T experiment. This system features a GPS module with millisecond-level timing precision, a low false-alarm rate, and high sensitivity to galactic core-collapse supernova explosion events. The methodology is robust, directly scalable, and planned for implementation in the next-generation PandaX-20T experiment.

hep-ex

Probing scalar-neutrino and scalar-dark-matter interactions with PandaX-4T

Scalar-mediated interactions may exist among neutrinos, dark matter particles, or between the two. Double $\beta$-decay experiments provide a powerful tool to probe such exotic interactions. Using $^{136}$Xe double $\beta$-decay data from PandaX-4T, we perform the first direct spectral search in the energy range of 20 to 2800~keV, setting the most stringent limits to date on scalar-mediated neutrino self-interactions for mediator masses below 2~MeV$/c^2$. These results place significant constraints on models invoking such interactions to alleviate the Hubble Tension. Assuming the same scalar also mediates dark matter self-interactions, constraints on the dark matter-scalar interactions can be placed in conjunction with cosmological constraints.

hep-ex

Tomographic beta-gamma spectroscopy of nuclear beta decay

Nuclear $\beta$ decay, a sensitive probe of nuclear structure and weak interactions, has become a precision test bed for physics beyond the Standard Model, driven by recent advances in spectrometric techniques. Here we introduce tomographic $\beta$-$\gamma$ spectroscopy (TBGS) of nuclear $\beta$ decay, a method that detects the energies of $\beta$, $\gamma$, and internal conversion electrons while simultaneously reconstructing the energy deposition vertices. Using the PandaX-4T detector operated as a TBGS, we obtain a precise and unbiased decay scheme of $^{214}$Pb, a key background isotope in searches for dark matter and Majorana neutrinos. For the first time, transitions of $^{214}$Pb to both the ground and excited states of $^{214}$Bi are measured concurrently, revealing discrepancies in branching ratios of up to 4.7$\sigma$ relative to previous evaluations. Combined with state-of-the-art theoretical spectral-shape calculations, these results establish a new benchmark for background modelling in rare-event searches and highlight the potential of TBGS as a versatile tool for fundamental physics and nuclear applications.

nucl-ex

Precise Measurement of $^{216}$Po Half-life with Exact Parent-daughter Pairing in PandaX-4T

We report a precise measurement of $^{216}\rm Po$ half-life using the PandaX-4T liquid xenon time projection chamber (TPC). $^{220}\rm Rn $, emanating from a $^{228}\rm Th $ calibration source, is injected to the detector and undergoes successive $\alpha$ decays, first to $^{216}\rm Po$ and then to $^{212}\rm Pb$. PandaX-4T detector measures the 5-dimensional (5D) information of each decay, including time, energy, and 3-dimensional positions. Therefore, we can identify the $^{220}\rm Rn $ and $^{216}\rm Po$ decay events and pair them exactly to extract the lifetime of each $^{216}\rm Po$. With a large data set and high-precision $^{220}\rm $Rn-$^{216}\rm $Po pairing technique, we measure the $^{216}\rm Po$ half-life to be $143.7\pm0.5$ ms, which is the most precise result to date and agrees with previously published values. The leading precision of this measurement demonstrates the power of 5D calorimeter and the potential of exact parent-daughter pairing in the xenon TPC.

nucl-ex

Search for Light Dark Matter with 259-day data in PandaX-4T

We present a search for light dark matter particles through their interactions with atomic electrons and nucleons, utilizing PandaX-4T data with an effective exposure of 1.04 tonne$\cdot$year for ionization-only data and 1.20 tonne$\cdot$year for paired data. Our analysis focuses on the energy range (efficiency$>$0.01) of approximately 0.33 to 3 keV for nuclear recoils, and from 0.04 to 0.39 keV for electronic recoils. We establish the most stringent constraints on spin-independent dark matter-nucleon interactions within a mass range of 2.5 to 5.0 GeV/$c^2$, spin-dependent neutron-only interactions within 2.0 to 5.3 GeV/$c^2$, and spin-dependent proton-only interactions within 2.0 to 3.8 GeV/$c^2$. Their corresponding limits at 3\,GeV/$c^2$ are $1.1 \times 10^{-43}$, $1.6 \times 10^{-38}$, and $5.6 \times 10^{-37}$\,cm$^2$, respectively. Additionally, our results improve the upper limits on the dark matter-electron scattering cross-section by a factor of 1.5 and 9.3 for heavy and light mediator scenarios respectively within 50 MeV/$c^2$ to 10 GeV/$c^2$, compared with previous best results.

hep-ex

Characterization of a gaseous time projection chamber with an internal \ce{^{37}Ar} source

We report on a novel calibration method of gaseous detectors using an internal \ce{^{37}Ar} source. The \ce{^{37}Ar} is a fast-decaying and low-energy calibration source that provides a mono-energetic peak of 2.82 keV. A gaseous \ce{^{37}Ar} source is injected and uniformly distributed in a Micromegas-based gaseous time projection chamber (TPC). Key performance parameters of the detector, such as electron transmission, gain, energy resolution, gain uniformity, and drift field evolution, are effectively and quickly calibrated. The gain uniformity, related to the homogeneity of the avalanche gap of Micromegas, is calibrated quickly thanks to the event-by-event position reconstruction and quasi-point energy deposition of \ce{^{37}Ar}. The energy resolution is improved with the obtained gain uniformity map. The most noticeable improvement in energy resolution, from 44.9\% to 35.4\%, is observed at a working pressure of 7 bar. The internal calibration source is also used to characterize the dependence of the detector's electric field distortion on the drift field.

physics.ins-det

Status and Prospects of the PandaX-III Experiment

The PandaX-III experiment searches the neutrinoless double beta decay of $^{136}$Xe with a high-pressure xenon gaseous time projection chamber~(TPC). Thermal-bonding Micromegas modules are used for charge collection. Benefitting from the excellent energy resolution and imaging capability, the background rate can be significantly suppressed through the topological information of events. The technology is successfully demonstrated by a prototype detector. The final detector has been constructed. In this paper, we will report the status of the PandaX-III experiment, including the construction and commissioning of the final detector, and the Micromegas-based TPC performance test in the prototype detector.

physics.ins-det

Calibration of a Micromegas-based Gaseous Time Projection Chamber Using Cosmic Ray Muons

We report the calibration of a gaseous Time Projection Chamber based on Micromegas charge readout modules with cosmic ray muons, utilizing their penetrating power and relatively uniform energy deposition per unit length. Muon events were selected through track reconstruction to characterize detector performances, such as the drift velocity, electron lifetime, detector gain, and electric field distortion. The evolution of detector performances with gas purities and electric drift fields over a 50-day data-taking cycle was measured by the muon calibration method. For instance, the drift velocity degraded with gas impurities from ${3.40\pm 0.07 ~ cm/μs}$ to ${3.06\pm 0.06 ~ cm/μs}$, and then recovered with gas purification. A ${^{137}Cs}$ calibration source was also placed inside the detector as a reference for muon calibrations.

physics.ins-det