Searcharxiv⌕ Search

arXiv subjects

Yuehuan Wei

Publications and source records attributed to Yuehuan Wei.

At least 37 records · Page 2Linked to original sources

Position reconstruction and surface background model for the PandaX-4T detector

We report the position reconstruction methods and surface background model for the PandaX-4T dark matter direct search experiment. This work develops two position reconstruction algorithms: template matching (TM) method and photon acceptance function (PAF) method. Both methods determine the horizontal position of events based on the light pattern of secondary scintillation collected by the light sensors. After a comprehensive evaluation of resolution, uniformity, and robustness, the PAF method was selected for position reconstruction, while the TM method was employed for verification. The PAF method achieves a bulk event resolution of 1.0 mm and a surface event resolution of 4.4 mm for a typical $S2$ signal with a bottom charge of 1500 PE (about 14 keV). The uniformity is around 20\%. Robustness studies reveal average deviations of 5.1 mm and 8.8 mm for the commissioning run (Run0) and the first science run (Run1), respectively, due to the deactivation of certain PMTs. A data-driven surface background model is developed based on the PAF method. The surface background is estimated to be $0.09 \pm 0.06$ events for Run0 (0.54 tonne$\cdot$year) and $0.17 \pm 0.11$ events for Run1 (1.00 tonne$\cdot$year).

physics.ins-det↗

Convolutional Neural Network-Based Neutron and Gamma Discrimination in EJ-276 for Low-Energy Detection

Organic scintillators are important in advancing nuclear detection and particle physics experiments. Achieving a high signal-to-noise ratio necessitates efficient pulse shape discrimination techniques to accurately distinguish between neutrons, gamma rays, and other particles within scintillator detectors. Although traditional charge comparison methods perform adequately for ~MeVee particles, their efficacy is significantly reduced in the lower energy region(<200 keVee). This paper introduces a particle identification method that harnesses the power of a convolutional neural network. We focused on the convolutional neural network's exceptional ability to discriminate between neutrons and gamma rays in the low-energy spectrum, utilizing a setup comprising a plastic scintillator EJ-276 and Silicon photomultiplier readout. Our findings reveal remarkable accuracies of 97.3% and 98.6% in the 0~100 keVee and 100~200 keVee energy ranges, respectively. These results represent substantial improvements of 13.8% and 4.25% over conventional methods. The enhanced discrimination power of the convolutional neural network method opens new frontiers for the application of organic scintillation detectors in low-energy rare event searches, including dark matter and neutrino detection.

physics.ins-det↗

Dark Matter Search Results from 1.54 Tonne$\cdot$Year Exposure of PandaX-4T

In this letter, we report the dark matter search results from the commissioning run and the first science run of the PandaX-4T experiment. A blind analysis is carried out on the entire data set. The data processing is improved compared to previous work, unifying the low-level signal reconstruction in a wide energy range up to 120 keV. With a total exposure of 1.54 tonne$\cdot$year, no significant excess of nuclear recoil events is found. The lowest 90% confidence level exclusion on the spin-independent cross section is $1.6 \times 10^{-47}\,\mathrm{cm}^2$ at a dark matter mass of 40 GeV$/c^2$. Our results represent the most stringent constraint for a dark matter mass above 100 GeV$/c^2$.

hep-ex↗

Exploring New Physics with PandaX-4T Low Energy Electronic Recoil Data

New particles beyond the standard model of particle physics, such as axions, can be effectively searched through their interactions with electrons. We use the large liquid xenon detector PandaX-4T to search for novel electronic recoil signals induced by solar axions, neutrinos with anomalous magnetic moment, axionlike particles, dark photons, and light fermionic dark matter. A detailed background model is established using the latest datasets with 1.54 $\rm ton \cdot yr$ exposure. No significant excess above the background has been observed, and we have obtained competitive constraints for axion couplings, neutrino magnetic moment, and fermionic dark matter interactions.

hep-ex↗

Searching for Neutrinoless Double-Beta Decay of $^{136}$Xe with PandaX-4T

We report the search for neutrinoless double-beta decay of $^{136}$Xe from the PandaX-4T experiment with a 3.7-tonne natural xenon target. The data reconstruction and the background modeling are optimized in the MeV energy region. A blind analysis is performed with data from the commissioning run and the first science run. No significant excess of signal over the background is observed. A lower limit on the half-life of $^{136}$Xe neutrinoless double-beta decay is established to be $2.1 \times 10^{24}$~yr at the 90\% confidence level, with a $^{136}$Xe exposure of 44.6~kg$\cdot$year. Our result represents the most stringent constraint from a natural xenon detector to date.

nucl-ex↗

PandaX-xT: a Multi-ten-tonne Liquid Xenon Observatory at the China Jinping Underground Laboratory

We propose a major upgrade to the existing PandaX-4T experiment in the China Jinping Underground Laboratory. The new experiment, PandaX-xT, will be a multi-ten-tonne liquid xenon, ultra-low background, and general-purpose observatory. The full-scaled PandaX-xT contains a 43-tonne liquid xenon active target. Such an experiment will significantly advance our fundamental understanding of particle physics and astrophysics. The sensitivity of dark matter direct detection will be improved by nearly two orders of magnitude compared to the current best limits, approaching the so-called "neutrino floor" for a dark matter mass above 10 GeV/$c^2$, providing a decisive test to the Weakly Interacting Massive Particle paradigm. By searching for the neutrinoless double beta decay of $^{136}$Xe isotope in the detector, the effective Majorana neutrino mass can be measured to a [10 -- 41] meV/$c^2$ sensitivity, providing a key test to the Dirac/Majorana nature of neutrino s. Astrophysical neutrinos and other ultra-rare interactions can also be measured and searched for with an unprecedented background level, opening up new windows of discovery. Depending on the findings, PandaX-xT will seek the next stage upgrade utilizing isotopic separation on natural xenon.

hep-ex↗

Reactor neutrino liquid xenon coherent elastic scattering experiment

Coherent elastic neutrino-nucleus scattering (CEvNS) provides a unique probe for neutrino properties Beyond the Standard Model (BSM) physics. REactor neutrino LIquid xenon Coherent Scattering experiment (RELICS), a proposed reactor neutrino program using liquid xenon time projection chamber (LXeTPC) technology, aims to investigate the CEvNS process of antineutrinos off xenon atomic nuclei. In this work, the design of the experiment is studied and optimized based on Monte Carlo (MC) simulations. To achieve a sufficiently low energy threshold for CEvNS detection, an ionization-only analysis channel is adopted for RELICS. A high emission rate of delayed electrons after a big ionization signal is the major background, leading to an analysis threshold of 120 photo-electrons in the CEvNS search. The second largest background, nuclear recoils induced by cosmic-ray neutrons, is suppressed via a passive water shield. The physics potential of RELICS is explored with a 32 kg*yr exposure at a baseline of 25 m from a reactor core with a 3 GW thermal power. In an energy range of 120 to 300 PE, corresponding to an average nuclear recoil from 0.63 to 1.36 keV considering the liquid xenon response and detector-related effect, we expect 4639.7 CEvNS and 1687.8 background events. The sensitivity of RELICS to the weak mixing angle is investigated at a low momentum transfer. Our study shows that RELICS can further improve the constraints on the non-standard neutrino interaction (NSI) compared to the current best results.

hep-ex↗

First Indication of Solar $^8$B Neutrino Flux through Coherent Elastic Neutrino-Nucleus Scattering in PandaX-4T

The PandaX-4T liquid xenon detector at the China Jinping Underground Laboratory is used to measure the solar $^8$B neutrino flux by detecting neutrinos through coherent scattering with xenon nuclei. Data samples requiring the coincidence of scintillation and ionization signals (paired), as well as unpaired ionization-only signals (US2), are selected with energy threshold of approximately 1.1 keV (0.33 keV) nuclear recoil energy. Combining the commissioning run and the first science run of PandaX-4T, a total exposure of 1.20 and 1.04 tonne$\cdot$year are collected for the paired and US2, respectively. After unblinding, 3 and 332 events are observed with an expectation of 2.8$\pm$0.5 and 251$\pm$32 background events, for the paired and US2 data, respectively. A combined analysis yields a best-fit $^8$B neutrino signal of 3.5 (75) events from the paired (US2) data sample, with $\sim$37\% uncertainty, and the background-only hypothesis is disfavored at 2.64$σ$ significance. This gives a solar $^8$B neutrino flux of ($8.4\pm3.1$)$\times$10$^6$ cm$^{-2}$s$^{-1}$, consistent with the standard solar model prediction. It is also the first indication of solar $^8$B neutrino ``fog'' in a dark matter direct detection experiment.

hep-ex↗

Search for Cosmic-ray Boosted Sub-MeV Dark-Matter-Electron Scattering in PandaX-4T

We report the first search for the elastic scatterings between cosmic-ray boosted sub-MeV dark matter and electrons in the PandaX-4T liquid xenon experiment. Sub-MeV dark matter particles can be accelerated by scattering with electrons in the cosmic rays and produce detectable electron recoil signals in the detector. Using the commissioning data from PandaX-4T of 0.63~tonne$\cdot$year exposure, we set new constraints on DM-electron scattering cross sections for DM masses ranging from 10~eV/$c^2$ to 3~keV/$c^2$.

hep-ex↗

Constraints on the axial-vector and pseudo-scalar mediated WIMP-nucleus interactions from PandaX-4T experiment

We present the constraints on the axial-vector and pseudo-scalar mediated WIMP-nucleus interactions from the PandaX-4T experiment, using the data set corresponding to a total exposure of 0.63~tonne$\cdot$year. No significant signal excess is observed, and the most stringent upper limits to date on the spin-dependent WIMP-neutron scattering cross section are set at 90\% confidence level with the minimum WIMP-neutron scattering cross section of 5.8$\times 10^{-42}$\si{\cm^{2}} for WIMP mass of 40~\si{\GeV/}$c^2$. Exclusion limits on the axial-vector and pseudo-scalar simplified models are also derived.

hep-ex↗

Measurement of Solar $pp$ Neutrino Flux using Electron Recoil Data from PandaX-4T Commissioning Run

The proton-proton ($pp$) fusion chain dominates the neutrino production from the Sun. The uncertainty of the predicted $pp$ neutrino flux is at the sub-percent level, whereas that of the best measurement is $\mathcal{O}(10\%)$. In this paper, we present the first result to measure the solar $pp$ neutrinos in the electron recoil energy range from 24 to 144 keV, using the PandaX-4T commissioning data with 0.63 tonne$\times$year exposure. The $pp$ neutrino flux is determined to be $(8.0 \pm 3.9 \,{\rm{(stat)}} \pm 10.0 \,{\rm{(syst)}} )\times 10^{10}\, $$\rm{s}^{-1} \rm{cm}^{-2}$, consistent with Standard Solar Model and existing measurements, corresponding to a flux upper limit of $23.3\times 10^{10}\, $$\rm{s}^{-1} \rm{cm}^{-2}$ at 90\% C.L..

hep-ex↗

Signal Response Model in PandaX-4T

PandaX-4T experiment is a deep-underground dark matter direct search experiment that employs a dual-phase time projection chamber with a sensitive volume containing 3.7 tonne of liquid xenon. The detector of PandaX-4T is capable of simultaneously collecting the primary scintillation and ionization signals, utilizing their ratio to discriminate dark matter signals from background sources such as gamma rays and beta particles. The signal response model plays a crucial role in interpreting the data obtained by PandaX-4T. It describes the conversion from the deposited energy by dark matter interactions to the detectable signals within the detector. The signal response model is utilized in various PandaX-4T results. This work provides a comprehensive description of the procedures involved in constructing and parameter-fitting the signal response model for the energy range of approximately 1 keV to 25 keV for electronic recoils and 6 keV to 90 keV for nuclear recoils. It also covers the signal reconstruction, selection, and correction methods, which are crucial components integrated into the signal response model.

physics.ins-det↗

Waveform Simulation in PandaX-4T

Signal reconstruction through software processing is a crucial component of the background and signal models in the PandaX-4T experiment, which is a multi-tonne dark matter direct search experiment. The accuracy of signal reconstruction is influenced by various detector artifacts, including noise, dark count of photomultiplier, impurity photoionization in the detector, and other relevant considerations. In this study, we present a detailed description of a semi-data-driven approach designed to simulate the signal waveform. This work provides a reliable model for the efficiency and bias of the signal reconstruction in the data analysis of PandaX-4T. By comparing critical variables which relate to the temporal shape and hit pattern of the signals, we demonstrate a good agreement between the simulation and data.

hep-ex↗

Searching for Two-Neutrino and Neutrinoless Double Beta Decay of $^{134}$Xe with the PandaX-4T Experiment

$^{134}$Xe is a candidate isotope for neutrinoless double beta decay~($0νββ$) search. In addition, the two-neutrino case ($2νββ$) allowed by the Standard Model of particle physics has not yet been observed. Utilizing the 10.4% of $^{134}$Xe in the natural xenon in the PandaX-4T detector and its first 94.9-day exposure, we have established the most stringent constraints on $2νββ$ and $0νββ$ of $^{134}$Xe half-lives, with limits of $2.8\times10^{22}$ yr and $3.0\times10^{23}$ yr at 90% confidence level, respectively. The $2νββ$ ($0νββ$) limit surpasses the previously reported best result by a factor of 32 (2.7), highlighting the potential of large monolithic natural xenon detectors.

nucl-ex↗

Detecting Neutrinos from Supernova Bursts in PandaX-4T

Neutrinos from core-collapse supernovae are essential for the understanding of neutrino physics and stellar evolution. The dual-phase xenon dark matter detectors can provide a way to track explosions of galactic supernovae by detecting neutrinos through coherent elastic neutrino-nucleus scatterings. In this study, a variation of progenitor masses as well as explosion models are assumed to predict the neutrino fluxes and spectra, which result in the number of expected neutrino events ranging from 6.6 to 13.7 at a distance of 10 kpc over a 10-second duration with negligible backgrounds at PandaX-4T. Two specialized triggering alarms for monitoring supernova burst neutrinos are built. The efficiency of detecting supernova explosions at various distances in the Milky Way is estimated. These alarms will be implemented in the real-time supernova monitoring system at PandaX-4T in the near future, providing the astronomical communities with supernova early warnings.

hep-ex↗

Search for Dark-Matter-Nucleon Interactions with a Dark Mediator in PandaX-4T

We report results of a search for dark-matter-nucleon interactions via a dark mediator using optimized low-energy data from the PandaX-4T liquid xenon experiment. With the ionization-signal-only data and utilizing the Migdal effect, we set the most stringent limits on the cross section for dark matter masses ranging from 30~$\rm{MeV/c^2}$ to 2~$\rm{GeV/c^2}$. Under the assumption that the dark mediator is a dark photon that decays into scalar dark matter pairs in the early Universe, we rule out significant parameter space of such thermal relic dark-matter model.

hep-ex↗

Search for light dark matter from atmosphere in PandaX-4T

We report a search for light dark matter produced through the cascading decay of $η$ mesons, which are created as a result of inelastic collisions between cosmic rays and Earth's atmosphere. We introduce a new and general framework, publicly accessible, designed to address boosted dark matter specifically, with which a full and dedicated simulation including both elastic and quasi-elastic processes of Earth attenuation effect on the dark matter particles arriving at the detector is performed. In the PandaX-4T commissioning data of 0.63 tonne$\cdot$year exposure, no significant excess over background is observed. The first constraints on the interaction between light dark matter generated in the atmosphere and nucleus through a light scalar mediator are obtained. The lowest excluded cross-section is set at $5.9 \times 10^{-37}{\rm cm^2}$ for dark matter mass of $0.1$ MeV$/c^2$ and mediator mass of 300 MeV$/c^2$. The lowest upper limit of $η$ to dark matter decay branching ratio is $1.6 \times 10^{-7}$.

hep-ex↗

Design optimization of JUNO-TAO plastic scintillator with WLS-fiber and SiPM readout

Plastic scintillators (PSs)embedded with wavelength-shifting fibers are widely used in high-energy particle physics, such as in muon taggers,as well as in medical physics and other applications. In this study,a simulation package was built to evaluate the effects of the diameter and layout of optical fibers on the light yield with different configurations. The optimal optical configuration was designed based on simulations and validated using two PS prototypes under certain experimental conditions. Atop veto tracker (TVT) for the JUNO-TAO experiment, comprising four layers of 160 strips of PS, was designed and evaluated. The threshold was evaluated when the muon tagging efficiency of a PS strip was >99%. The efficiency of three layer out of four layer of TVT is >99%,even with a tagging efficiency of a single strip as low as 97%, using a threshold of 10 photoelectrons and assuming a 40%silicon PM photon detection efficiency.

physics.ins-det↗