Searcharxiv⌕ Search

arXiv subjects

Yuki Sakurai

Publications and source records attributed to Yuki Sakurai.

At least 19 recordsLinked to original sources

Model of the instrumental polarization induced by a rotating HWP with anti-reflective sub-wavelength structures for CMB polarimetry

Future CMB polarization experiments require precise control of instrumental systematics in the search for primordial $B$-mode polarization. A rotating half-wave plate (HWP) provides effective polarization modulation, but its non-ideal electromagnetic response can generate HWP-synchronous instrumental polarization. In this work, we characterize the response of a multi-layer sapphire HWP with anti-reflective sub-wavelength structures (SWS) using rigorous coupled-wave analysis. For three asymmetric SWS models, we find no substantial differences in the transmittance, polarization efficiency, or instrumental-polarization response that can be attributed to the type of SWS asymmetry. The fourth-harmonic instrumental polarization relevant to CMB polarization reconstruction is typically of order $10^{-4}$ in the CMB bands, which is expected to be mitigated. We further evaluate an actually fabricated SWS geometry, whose asymmetry enhances the retardance, and compare its response with that of an idealized model having the same type of asymmetry. Comparison of the realistic SWS with the idealized model shows that higher transmittance tends to be associated with lower instrumental polarization. These results suggest that improving the total transmission, including the effect of the fabricated SWS profile, may be more important for reducing HWP-induced instrumental polarization than tuning the SWS asymmetry itself.

astro-ph.IM↗

Search for Dark Photon Dark Matter at 74--159 $μ$eV/$c^2$ Using Broadband Cryogenic Receivers

Dark photons are hypothetical massive vector bosons that couple to ordinary photons through kinetic mixing $χ$. Dark photon dark matter (DPDM) converts into photons at a metal surface, with a frequency set by its mass. Using cryogenic K- and Ka-band receivers with a broadband spectrometer, we searched for this signal over 74--159 $μ$eV/$c^2$ (18--38.5 GHz) with an integration time of $4.8\times10^5$ s per frequency bin. We found no statistically significant signal and set upper limits of $χ<(3.1$--$17)\times10^{-12}$ at the 95% confidence level over 99.8% of the search range, assuming DPDM constitutes all local dark matter. These results improve on previous limits by more than an order of magnitude over most of 74--110 $μ$eV/$c^2$ and provide the first direct limits over most of 110--159 $μ$eV/$c^2$, approximately two orders of magnitude below cosmological bounds.

hep-ex↗

HWP-synchronous signal induced by misalignment of the sapphire crystal axis

We investigate the optical response of a rotating sapphire half-wave plate (HWP) with optic axis misalignment, defined as a deviation of the optic axis from the ideal a-cut orientation. We extend the transfer-matrix formalism for calculating the modulated transmittance of multi-layer wave plates with optic axis misalignment and oblique incidence. Using this formalism, we compute the modulated response of a rotating HWP with an optic axis misalignment to linearly polarized incident light. We experimentally validate the model at 90 GHz using sapphire wave plates with intentionally introduced optic axis misalignments of up to 30 degrees. Additional even harmonics are observed for oblique incidence and optic axis misalignment, with odd harmonics appearing when both effects are present. The measured modulation signals are in good agreement with the model predictions. We also evaluate the potential impact of a illustrative small optic axis misalignment of 3 degrees on precision polarimetry. For the configuration considered, the model predicts odd-harmonic amplitudes at the percent level for a single-layer HWP and up to 8% at individual frequencies for a five-layer achromatic HWP.

astro-ph.IM↗

The Simons Observatory: Rotation Performance of Cryogenic Half-Wave Plate Polarization Modulators

We present the on-site rotation performance of the first three cryogenic continuously rotating half-wave plate (HWP) polarization modulators for the Simons Observatory small aperture telescopes (SATs). The SATs operate at an altitude of 5200 m in the Atacama Desert in northern Chile, and measure the degree-scale cosmic microwave background polarization to search for primordial $B$-mode polarization. To this end, the SATs employ a 505 mm diameter 50 K cryogenic HWP polarization modulator to suppress atmospheric $1/f$ noise and to mitigate systematic uncertainties. We present methods for reconstructing the rotation of our polarization modulators, enabling detailed evaluations of their rotation angle accuracy, stability, displacements, and vibrations. We achieve the required rotation angle accuracy in more than 99.9% of observations, with a median noise level of $0.16\,μ\text{rad}\sqrt{\text{s}}$. We also achieve one-dimensional measurement of the rotor displacement with an accuracy of $0.06\,μ\text{m}\sqrt{\text{s}}$. Our results demonstrate the on-site rotation performance, rotation angle reconstruction method, and robustness of the polarization modulators. This is a crucial step towards achieving the SAT science goals.

astro-ph.IM↗

The Simons Observatory: Commissioning of the Mid-Frequency Small Aperture Telescopes

The Simons Observatory (SO) is a cosmic microwave background (CMB) survey experiment observing from an altitude of 5,200 m in the Atacama Desert in Chile. The SO Small Aperture Telescopes (SATs) will cover six spectral bands between 30 and 280 GHz primarily to search for evidence of primordial gravitational waves in the large angular scale $B$-modes of the CMB polarization. The first two Mid-Frequency (MF) SATs, operating in the 90 and 150 GHz frequency bands, began commissioning observations in late 2023, and we present the results of those observations here. Each MF SAT operates with approximately 9,400 biased transition-edge sensors (TES) at 1 mm of precipitable water vapor (PWV), representing a typical 80% yield. Planet observations confirm the telescope optics performance, calibrate the instrument response, and measure the end-to-end optical efficiency of the SATs. The realized instrument efficiencies are within the range expected based on instrument model predictions. In nominal observing conditions, the noise equivalent temperatures from both telescopes combined are $2.4~\mathrm{μK_{CMB}\sqrt{s}}$ at 90 GHz and $3.2~\mathrm{μK_{CMB}\sqrt{s}}$ at 150 GHz, substantially outperforming the baseline instantaneous sensitivity targets for the observatory.

astro-ph.IM↗

The Simons Observatory: Overview of the Cryogenic Half-wave Plate Polarization Modulators

The Simons Observatory (SO) is a ground-based Cosmic Microwave Background (CMB) experiment that is located in the Atacama plateau. The Small Aperture Telescopes (SATs) of SO are optimized for polarimetry on the degree scale. Atmospheric $1/f$ contamination of the CMB signal poses a significant challenge for observations at this angular scale. In order to control the $1/f$ noise, the SATs utilize a Cryogenic Half-Wave Plate (CHWP) in their optics. The CHWP modulates the polarization signal to a higher frequency to separate it from the unpolarized atmospheric noise. Precision measurements of the CHWP rotation angle are required to successfully recover the target polarized signals. We present a method to reconstruct the CHWP rotation angle that achieves a noise level of 0.16 $μ\mathrm{rad\sqrt{s}}$, meeting our requirement.

astro-ph.IM↗

3D Printed Alumina as a Millimeter-Wave Optical Element

We present millimeter and sub-millimeter room temperature transmission and loss measurements of 3D printed alumina disc and of a disc with one-sided 3D printed sub-wavelength structures anti-reflection coatings (SWS-ARC). For four bands spanning 158 - 700~GHz we find an index of refraction consistent with $n= 3.107 \pm 0.007$. The loss over the entire frequency band between 158~GHz and 700~GHz spans $ 1 \cdot 10^{-3} \leq \tan δ\leq 2.49 \cdot 10^{-3}$ with 10%-30% uncertainty at the lower range of frequencies shrinking to $\sim\!2\%$ at the higher frequencies. As expected, constructive and destructive interference fringes that are apparent with the flat disc data are absent with the disc that has SWS-ARC. The measured data are consistent with finite element analysis predictions that are based on the measured shape of the SWS. At frequencies between 158~GHz and 200~GHz, below the onset of diffraction effects, reflectance is reduced from a maximum of 64% to about 25%, closely matching predictions. These measurements of the index, loss, and SWS-ARC of 3D printed alumina suggest that the material and fabrication technique could be useful for astrophysical applications.

astro-ph.IM↗

Laser ablated sub-wavelength structure anti-reflection coating on an alumina lens

We used laser ablation to fabricate sub-wavelength structure anti-reflection coating (SWS-ARC) on a 5 cm diameter alumina lens. With an aspect ratio of 2.5, the SWS-ARC are designed to give a broad-band low reflectance response between 110 and 290 GHz. SWS shape measurements conducted on both sides of the lens give 303 $μ$m pitch and total height between 750 and 790 $μ$m, matching or exceeding the aspect ratio design values. Millimeter-wave transmittance measurements in a band between 140 and 260 GHz show the increase in transmittance expected with the ARC when compared to finite element analysis electromagnetic simulations. To our knowledge, this is the first demonstration of SWS-ARC on an alumina lens, opening the path for implementing the technique for larger diameter lenses.

astro-ph.IM↗

The Simons Observatory: Large Diameter and Large Load-Capacity Superconducting Magnetic Bearing for a Millimeter-Wave Polarization Modulator

We present the design methodology and characterization of a superconducting magnetic bearing (SMB) system for the polarization modulator in the SAT-LF, one of the small aperture telescopes (SATs) in the Simons Observatory (SO) that is sensitive at 30/40 GHz frequency bands. SO is a ground-based cosmic microwave background (CMB) polarization experiment, with the SATs specifically aiming to search for primordial parity-odd polarization anisotropies at degree scales. Each SAT is equipped with a cryogenic, continuously rotating half-wave plate (HWP) as a polarization modulator to mitigate atmospheric $1/f$ noise and instrumental systematics. The HWP system employs an SMB, consisting of a ring-shaped magnet and superconductor, to achieve a 550 mm clear aperture and stable 2 Hz rotation at a temperature of around 50 K. One challenge for the HWP system in the SAT-LF is the large 35 kg load on the SMB due to the thicker HWP than in previous telescopes. Since the SMB stiffness is critical for maintaining the alignment of the HWP in the telescope, we developed a method to quantitatively predict the stiffness using finite element simulations with the so-called H-formulation. We evaluated the stiffness for various geometries of the magnet and superconductor, thereby optimizing their dimensions. The prediction is in excellent agreement with experimental measurements of the fabricated SMB, demonstrating a $\sim$5\% accuracy. We also demonstrated that the SMB achieves sufficiently low friction-induced heat dissipation, measured at 0.26 W when rotating at 2 Hz. The design methodology and the implementation of the SMB demonstrated here not only provides an enabling technology for the SO SAT-LF, but also is a crucial stepping stone for future CMB experiments that make use of HWP polarization modulators.

astro-ph.IM↗

The Simons Observatory: Design, integration, and testing of the small aperture telescopes

The Simons Observatory (SO) is a cosmic microwave background (CMB) survey experiment that includes small-aperture telescopes (SATs) observing from an altitude of 5,200 m in the Atacama Desert in Chile. The SO SATs will cover six spectral bands between 27 and 280 GHz to search for primordial B-modes to a sensitivity of $σ(r)=0.002$, with quantified systematic errors well below this value. Each SAT is a self-contained cryogenic telescope with a 35$^\circ$ field of view, 42 cm diameter optical aperture, 40 K half-wave plate, 1 K refractive optics, and $<0.1$ K focal plane that holds $>12,000$ TES detectors. We describe the nominal design of the SATs and present details about the integration and testing for one operating at 93 and 145 GHz.

astro-ph.IM↗

The Simons Observatory: Development and Optical Evaluation of Achromatic Half-Wave Plates

The Simons Observatory (SO) experiment is a cosmic microwave background (CMB) experiment located in the Atacama Desert, Chile. The SO' s small aperture telescopes (SATs) consist of three telescopes designed for precise CMB polarimetry at large angular scales. Each SAT uses a cryogenic rotating half-wave plate (HWP) as a polarization modulator to mitigate atmospheric 1/f noise and other systematics. To realize efficient polarization modulation over the observation bands, we fabricated an achromatic HWP (AHWP) consisting of three sapphire plates with anti-reflection coatings. The AHWP is designed to have broadband modulation efficiency and transmittance. This paper reports on the design and the preliminary characterization of the AHWPs for SATs.

astro-ph.IM↗

Anti-reflection coating with mullite and Duroid for large-diameter cryogenic sapphire and alumina optics

We developed a broadband two-layer anti-reflection (AR) coating for use on a sapphire half-wave plate (HWP) and an alumina infrared (IR) filter for the cosmic microwave background (CMB) polarimetry. Measuring the faint CMB B-mode signals requires maximizing the number of photons reaching the detectors and minimizing spurious polarization due to reflection with an off-axis incident angle. Sapphire and alumina have high refractive indices of 3.1 and are highly reflective without an AR coating. This paper presents the design, fabrication, quality control, and measured performance of an AR coating using thermally-sprayed mullite and Duroid 5880LZ. This technology enables large optical elements with diameters of 600 mm. We also present a newly developed thermography-based nondestructive quality control technique, which is key to assuring good adhesion and preventing delamination when thermal cycling. We demonstrate the average reflectance of about 2.6% (0.9%) for two observing bands centered at 90/150 (220/280) GHz. At room temperature, the average transmittance of a 105 mm square test sample at 220/280 GHz is 83%, and it will increase to 90% at 100 K, attributed to reduced absorption losses. Therefore, our developed layering technique has proved effective for 220/280 GHz applications, particularly in addressing dielectric loss concerns. This AR coating technology has been deployed in the cryogenic HWP and IR filters of the Simons Array and the Simons observatory experiments and applies to future experiments such as CMB-S4.

astro-ph.IM↗

Vibration characteristics of a continuously rotating superconducting magnetic bearing and potential influence to TES and SQUID

We measured the vibration of a prototype superconducting magnetic bearing (SMB) operating at liquid nitrogen temperature. This prototype system was designed as a breadboard model for LiteBIRD low-frequency telescope (LFT) polarization modulator unit. We set an upper limit of the vibration amplitude at $36~\mathrm{μm}$ at the rotational synchronous frequency. During the rotation, the amplitude of the magnetic field produced varies. From this setup, we compute the static and AC amplitude of the magnetic fields produced by the SMB magnet at the location of the LFT focal plane as $0.24~\mathrm{G}$ and $3\times10^{-5}$$~\mathrm{G}$, respectively. From the AC amplitude, we compute TES critical temperature variation of $7\times10^{-8}$$~\mathrm{K}$ and fractional change of the SQUID flux is $δΦ/Φ_0|_{ac}=3.1\times10^{-5}$. The mechanical vibration can be also estimated to be $3.6\times 10^{-2}$$~\mathrm{N}$ at the rotation mechanism location.

physics.ins-det↗

Broadband multi-layer anti-reflection coatings with mullite and duroid for half-wave plates and alumina filters for CMB polarimetry

A broadband two-layer anti-reflection (AR) coating was developed for use on a sapphire half-wave plate (HWP) and an alumina infrared (IR) filter for cosmic microwave background (CMB) polarimetry. Measuring tiny CMB B-mode signals requires maximizing the number of photons reaching the detectors and minimizing spurious polarization due to reflection with an off-axis incident angle. However, a sapphire HWP and an alumina IR filter have high refractive indices of about 3.1, and an AR coating must be applied to them. Thermally sprayed mullite and Duroid 5880LZ were selected in terms of index and coefficient of thermal expansion for use at cryogenic temperatures. With these materials, the reflectivity was reduced to about 2% at 90/150 GHz and <1% at 220/280 GHz. The design, fabrication, and optical performance evaluation of the AR coatings are described. The coatings were used in a current ground-based CMB experiment called the Simons Array. They could also be applied to next-generation CMB experiments, such as the Simons Observatory.

astro-ph.IM↗

Testbed preparation of a small prototype polarization modulator for LiteBIRD low-frequency telescope

LiteBIRD is the Cosmic Microwave Background (CMB) radiation polarization satellite mission led by ISAS/JAXA. The main scientific goal is to search for primordial gravitational wave signals generated from the inflation epoch of the Universe. LiteBIRD telescopes employ polarization modulation units (PMU) using continuously rotating half-wave plates (HWP). The PMU is a crucial component to reach unprecedented sensitivity by mitigating systematic effects, including 1/f noise. We have developed a 1/10 scale prototype PMU of the LiteBIRD LFT, which has a 5-layer achromatic HWP and a diameter of 50 mm, spanning the observational frequency range of 34-161 GHz. The HWP is mounted on a superconducting magnetic bearing (SMB) as a rotor and levitated by a high-temperature superconductor as a stator. In this study, the entire PMU system is cooled down to 10 K in the cryostat chamber by a 4-K Gifford-McMahon (GM) cooler. We propagate an incident coherent millimeter-wave polarized signal throughout the rotating HWP and detect the modulated signal. We study the modulated optical signal and any rotational synchronous signals from the rotation mechanism. We describe the testbed system and the preliminary data acquired from this setup. This testbed is built to integrate the broadband HWP PMU and evaluate the potential systematic effects in the optical data. This way, we can plan with a full-scale model, which takes a long time for preparation and testing.

astro-ph.IM↗

Modelling TES non-linearity induced by a rotating HWP in a CMB polarimeter

Most upcoming CMB experiments are planning to deploy between a few thousand and a few hundred thousand TES bolometers in order to drastically increase sensitivity and unveil the B-mode signal. Differential systematic effects and $1/f$ noise are two of the challenges that need to be overcome in order to achieve this result. In recent years, rotating Half-Wave Plates have become increasingly more popular as a solution to mitigate these effects, especially for those experiments that are targeting the largest angular scales. However, other effects may appear when a rotating HWP is being employed. In this paper we focus on HWP synchronous signals, which are due to intensity to polarization leakage induced by a rotating cryogenic multi-layer sapphire HWP employed as the first optical element of the telescope system. We use LiteBIRD LFT as a case study and we analyze the interaction between these spurious signals and TES bolometers, to determine whether this signal can contaminate the bolometer response. We present the results of simulations for a few different TES model assumptions and different spurious signal amplitudes. Modelling these effects is fundamental to find what leakage level can be tolerated and minimize non-linearity effects of the bolometer response.

astro-ph.IM↗

Testing magnetic interference between TES detectors and the telescope environment for future CMB satellite missions

The two most common components of several upcoming CMB experiments are large arrays of superconductive TES (Transition-Edge Sensor) detectors and polarization modulator units, e.g. continuously-rotating Half-Wave Plates (HWP). A high detector count is necessary to increase the instrument raw sensitivity, however past experiments have shown that systematic effects are becoming one of the main limiting factors to reach the sensitivity required to detect primordial $B$-modes. Therefore, polarization modulators have become popular in recent years to mitigate several systematic effects. Polarization modulators based on HWP technologies require a rotating mechanism to spin the plate and modulate the incoming polarized signal. In order to minimize heat dissipation from the rotating mechanism, which is a stringent requirement particularly for a space mission like $LiteBIRD$, we can employ a superconductive magnetic bearing to levitate the rotor and achieve contactless rotation. A disadvantage of this technique is the associated magnetic fields generated by those systems. In this paper we investigate the effects on a TES detector prototype and find no detectable $T_c$ variations due to an applied constant (DC) magnetic field, and a non-zero TES response to varying (AC) magnetic fields. We quantify a worst-case TES responsivity to the applied AC magnetic field of $\sim10^5$ pA/G, and give a preliminary interpretation of the pick-up mechanism.

astro-ph.IM↗

A Large Diameter Millimeter-Wave Low-Pass Filter Made of Alumina with Laser Ablated Anti-Reflection Coating

We fabricated a 302 mm diameter low-pass filter made of alumina that has an anti-reflection coating (ARC) made with laser-ablated sub-wavelength structures (SWS). The filter has been integrated into and is operating with the MUSTANG2 instrument, which is coupled to the Green Bank Telescope. The average transmittance of the filter in the MUSTANG2 operating band between 75 and 105 GHz is 98%. Reflective loss due to the ARC is 1%. The difference in transmission between the s- and p-polarization states is less than 1%. To within 1% accuracy we observe no variance in these results when transmission is measured in six independent filter spatial locations. The alumina filter replaced a prior MUSTANG2 Teflon filter. Data taken with the filter heat sunk to its nominal 40 K stage show performance consistent with expectations: a reduction of about 50% in filters-induced optical power load on the 300 mK stage, and in in-band optical loading on the detectors. It has taken less than 4 days to laser-ablate the SWS on both sides of the alumina disk. This is the first report of an alumina filter with SWS ARC deployed with an operating instrument, and the first demonstration of a large area fabrication of SWS with laser ablation.

astro-ph.IM↗