SearcharxivSearch

arXiv subjects

Yuntao Zhu

Publications and source records attributed to Yuntao Zhu.

7 recordsLinked to original sources

Overcoming noise-agility trade-off in integrated lasers for precision sensing

Lasers that combine narrow linewidths with rapid tunability are critical for applications such as coherent optical ranging, distributed fiber-optic sensing, and precision spectroscopy. Despite significant progress in integrated laser technologies, the concurrent realization of low phase noise and frequency agility on a single integrated platform remains challenging owing to a fundamental architectural trade-off: conventional integrated laser designs typically suppress phase noise via high-$Q$ resonators, yet the extended photon lifetimes inherent to such resonators intrinsically constrain tuning speed. Here, we address this noise-agility trade-off by introducing a laser architecture that achieves ultralow phase noise and ultrafast tunability simultaneously. Rather than relying on ultrahigh-$Q$ resonators for self-injection locking, our design employs strong synthetic feedback within a Pockels-tunable, resonator-enhanced distributed Bragg reflector to suppress phase noise. As a proof of concept, we demonstrate a hybrid integrated laser with a short-term linewidth of 29 Hz, realized using a lithium niobate external cavity with a loaded $Q$ of only 0.62 million. The adoption of a moderate resonator $Q$ relaxes the photon-lifetime constraint on tuning speed, enabling sub-exahertz-per-second tuning rates and a chirp nonlinearity as low as 0.14%. Leveraging this laser, we implement a frequency-modulated continuous-wave LiDAR system that achieves a relative ranging precision of $1.7 \times 10^{-4}$ at a measurement rate of $1\,\text{MSa s}^{-1}$, without requiring complex chirp linearization techniques. We further demonstrate fiber-optic acoustic sensing capable of detecting sub-$με$ dynamic strain, underscoring the platform's versatility for high-speed precision optical measurements. Our work provides a route toward cost-effective yet high-performance sensing and metrology systems.

physics.optics

Precise and Robust Domain Engineering Based on Faraday Cage Effect for Thin-film Lithium Niobate Photonics

Thin-film lithium niobate (TFLN) waveguides are promising for efficient second-harmonic generation (SHG) owing to their strong optical confinement and large second-order nonlinearity. However, robust fabrication of high-efficiency devices remains challenging, as existing domain engineering methods lack precise and robust controls of polarity distributions. Here, we propose and demonstrate a domain engineering technique that utilizes nanoscale Faraday cages to shape the electric-field distributions during poling, physically defining polarity distribution by the geometry of the Faraday cages without real-time monitoring. As a proof of concept, the method is used to fabricate a spatially selectively poled TFLN waveguide, where all regions are poled except for a 400-nm-wide central. This waveguide achieves a normalized SHG efficiency of 6242 %W-1cm-2. Systematic investigation of the inverted domain growth dynamics confirms the enhanced precision and robustness of this approach over conventional time-controlled methods, paving the way for scalable nonlinear photonic circuits.

physics.optics

Standardized Evaluation of Automatic Methods for Perivascular Spaces Segmentation in MRI -- MICCAI 2024 Challenge Results

Perivascular spaces (PVS), when abnormally enlarged and visible in magnetic resonance imaging (MRI) structural sequences, are important imaging markers of cerebral small vessel disease and potential indicators of neurodegenerative conditions. Despite their clinical significance, automatic enlarged PVS (EPVS) segmentation remains challenging due to their small size, variable morphology, similarity with other pathological features, and limited annotated datasets. This paper presents the EPVS Challenge organized at MICCAI 2024, which aims to advance the development of automated algorithms for EPVS segmentation across multi-site data. We provided a diverse dataset comprising 100 training, 50 validation, and 50 testing scans collected from multiple international sites (UK, Singapore, and China) with varying MRI protocols and demographics. All annotations followed the STRIVE protocol to ensure standardized ground truth and covered the full brain parenchyma. Seven teams completed the full challenge, implementing various deep learning approaches primarily based on U-Net architectures with innovations in multi-modal processing, ensemble strategies, and transformer-based components. Performance was evaluated using dice similarity coefficient, absolute volume difference, recall, and precision metrics. The winning method employed MedNeXt architecture with a dual 2D/3D strategy for handling varying slice thicknesses. The top solutions showed relatively good performance on test data from seen datasets, but significant degradation of performance was observed on the previously unseen Shanghai cohort, highlighting cross-site generalization challenges due to domain shift. This challenge establishes an important benchmark for EPVS segmentation methods and underscores the need for the continued development of robust algorithms that can generalize in diverse clinical settings.

q-bio.QM

On-chip real-time detection of optical frequency variations with ultrahigh resolution using the sine-cosine encoder approach

Real-time measurement of optical frequency variations (OFVs) is crucial for various applications including laser frequency control, optical computing, and optical sensing. Traditional devices, though accurate, are often too large, slow and costly. Here we present a photonic integrated circuit (PIC) chip, utilizing the sine-cosine encoder principle, for high-speed and high-resolution real-time OFV measurement. Fabricated on a thin film lithium niobate (TFLN) platform, this chip-sized optical frequency detector (OFD) (5.5 mm * 2.7 mm) achieves a speed of up to 2500 THz/s and a resolution as fine as 2 MHz over a range exceeding 160 nm. Our robust algorithm overcomes the device imperfections and ensures precise quantification of OFV parameters. As a practical demonstration, the PIC OFD surpasses existing fiber Bragg grating (FBG) interrogators in sensitivity and speed for strain and vibration measurements. This work opens new avenues for on-chip OFV detection and offers significant potential for diverse applications involving OFV measurement.

physics.optics

120 GOPS Photonic Tensor Core in Thin-film Lithium Niobate for Inference and in-situ Training

Photonics offers a transformative approach to artificial intelligence (AI) and neuromorphic computing by enabling low-latency, high-speed, and energy-efficient computations. However, conventional photonic tensor cores face significant challenges in constructing large-scale photonic neuromorphic networks. Here, we propose a fully integrated photonic tensor core, consisting of only two thin-film lithium niobate (TFLN) modulators, a III-V laser, and a charge-integration photoreceiver. Despite its simple architecture, it is capable of implementing an entire layer of a neural network with a computational speed of 120 GOPS, while also allowing flexible adjustment of the number of inputs (fan-in) and outputs (fan-out). Our tensor core supports rapid in-situ training with a weight update speed of 60 GHz. Furthermore, it successfully classifies (supervised learning) and clusters (unsupervised learning) 112 * 112-pixel images through in-situ training. To enable in-situ training for clustering AI tasks, we offer a solution for performing multiplications between two negative numbers.

physics.optics

Morphology Edge Attention Network and Optimal Geometric Matching Connection model for vascular segmentation

There are many unsolved problems in vascular image segmentation, including vascular structural connectivity, scarce branches and missing small vessels. Obtaining vessels that preserve their correct topological structures is currently a crucial research issue, as it provides an overall view of one vascular system. In order to preserve the topology and accuracy of vessel segmentation, we proposed a novel Morphology Edge Attention Network (MEA-Net) for the segmentation of vessel-like structures, and an Optimal Geometric Matching Connection (OGMC) model to connect the broken vessel segments. The MEA-Net has an edge attention module that improves the segmentation of edges and small objects by morphology operation extracting boundary voxels on multi-scale. The OGMC model uses the concept of curve touching from differential geometry to filter out fragmented vessel endpoints, and then employs minimal surfaces to determine the optimal connection order between blood vessels. Finally, we calculate the geodesic to repair missing vessels under a given Riemannian metric. Our method achieves superior or competitive results compared to state-of-the-art methods on four datasets of 3D vascular segmentation tasks, both effectively reducing vessel broken and increasing vessel branch richness, yielding blood vessels with a more precise topological structure.

eess.IV

Towards Data-Efficient Learning: A Benchmark for COVID-19 CT Lung and Infection Segmentation

Purpose: Accurate segmentation of lung and infection in COVID-19 CT scans plays an important role in the quantitative management of patients. Most of the existing studies are based on large and private annotated datasets that are impractical to obtain from a single institution, especially when radiologists are busy fighting the coronavirus disease. Furthermore, it is hard to compare current COVID-19 CT segmentation methods as they are developed on different datasets, trained in different settings, and evaluated with different metrics. Methods: To promote the development of data-efficient deep learning methods, in this paper, we built three benchmarks for lung and infection segmentation based on 70 annotated COVID-19 cases, which contain current active research areas, e.g., few-shot learning, domain generalization, and knowledge transfer. For a fair comparison among different segmentation methods, we also provide standard training, validation and testing splits, evaluation metrics and, the corresponding code. Results: Based on the state-of-the-art network, we provide more than 40 pre-trained baseline models, which not only serve as out-of-the-box segmentation tools but also save computational time for researchers who are interested in COVID-19 lung and infection segmentation. We achieve average Dice Similarity Coefficient (DSC) scores of 97.3\%, 97.7\%, and 67.3\% and average Normalized Surface Dice (NSD) scores of 90.6\%, 91.4\%, and 70.0\% for left lung, right lung, and infection, respectively. Conclusions: To the best of our knowledge, this work presents the first data-efficient learning benchmark for medical image segmentation and the largest number of pre-trained models up to now. All these resources are publicly available, and our work lays the foundation for promoting the development of deep learning methods for efficient COVID-19 CT segmentation with limited data.

eess.IV