SearcharxivSearch

arXiv subjects

Yupeng Xu

Publications and source records attributed to Yupeng Xu.

At least 19 recordsLinked to original sources

ImProNCDE: Impulse-Corrected Neural Controlled Differential Equations with Prototype Learning for Longitudinal Prognosis Prediction

Longitudinal ophthalmic imaging analysis is an essential step for prognosis prediction in ophthalmic diseases. However, AI-assisted prognosis models are challenged by follow-up sequences, which tend to be sparse, irregularly sampled, and incomplete. Although advanced prognosis modeling methods, especially for the methods based on neural controlled differential equations (NCDEs), provide a principled continuous-time framework for sparse and irregular longitudinal data. Unfortunately, two major concerns remain unsolved in clinical follow-up modeling. First, the smooth latent dynamics of standard NCDEs is poorly matched to abrupt pathological changes induced by therapeutic intervention, lesion recurrence, or long follow-up gaps. Second, numerical integration over long horizons can accumulate errors, which will produce unstable latent trajectories and weakened class discrimination. To address these challenges, we propose ImProNCDE, an impulse-corrected NCDE framework with prototype learning for longitudinal ophthalmic prognosis prediction. To capture abrupt pathological changes beyond smooth latent dynamics, ImProNCDE introduces Residual Impulse Calibration (RIC), which injects residual-based impulse corrections at visit times and then recalibrates the latent state when observations deviate from continuous predictions. To further mitigate error accumulation over long horizons, we introduce a Prototype-guided Trajectory Stabilizer (PTS), which aims to attract latent trajectories toward learnable prognosis prototypes to reduce class overlap and which ultimately improves long-horizon stability. Experiments on multiple private and public longitudinal ophthalmic datasets (totalling over 1206 samples) show that ImProNCDE outperforms existing SOTA methods focusing on sequence modeling.

cs.CE

The enhanced X-ray Timing and Polarimetry mission -- eXTP for launch in 2030

In this paper we present the current status of the enhanced X-ray Timing and Polarimetry mission, which has been fully approved for launch in 2030. eXTP is a space science mission designed to study fundamental physics under extreme conditions of matter density, gravity, and magnetism. The mission aims at determining the equation of state of matter at supra-nuclear density, measuring the effects of quantum electro-dynamics, and understanding the dynamics of matter in strong-field gravity. In addition to investigating fundamental physics, the eXTP mission is poised to become a leading observatory for time-domain and multi-messenger astronomy in the 2030's, as well as providing observations of unprecedented quality on a variety of galactic and extragalactic objects. After briefly introducing the history and a summary of the scientific objectives of the eXTP mission, this paper presents a comprehensive overview of: 1) the cutting-edge technology, technical specifications, and anticipated performance of the mission's scientific instruments; 2) the full mission profile, encompassing spacecraft design, operational capabilities, and ground segment infrastructure.

astro-ph.HE

PSR J1231-1411 revisited: Pulse Profile Analysis of X-ray Observation

One of the primary goals of Neutron Star Interior Composition Explorer (NICER)-like X-ray missions is to impose stringent constraints on the neutron star equation of state by precisely measuring their masses and radii. NICER has recently expanded the dataset of inferred mass-radius relations for neutron stars, including four rotation-powered millisecond pulsars PSR J0030+0451, PSR J0740+6620, PSR J0437-4715, and PSR J1231-1411. In this work, the mass-radius relation and X-ray emitting region properties of PSR J1231-1411 are inferred with an independent pulse profile modeling based on the spherical star Schwarzschild-spacetime and Doppler approximation. With one single-temperature elongated hot spot and one single-temperature crescent hot spot, the inferred gravitational mass is $M = 1.12 \pm 0.07 M_{\odot}$ and the inferred equatorial radius is $R_{eq} = 9.91_{-0.86}^{+0.88}$ km (68% credible intervals). It provides an alternative geometry configuration of the X-ray emitting region for PSR J1231-1411 to sufficiently explain the observation data of NICER and XMM-Newton. The inferred radius is smaller than that derived by \citet{salmi2024nicer} ($M = 1.04_{-0.03}^{+0.05} M_{\odot}$, $R_{eq} = 12.6 \pm 0.3$ km), and the inferred mass is slightly higher in this work. The inferred geometry configurations of the X-ray emitting region in both works are non-antipodal, which is not consistent with a centered dipole magnetic field and suggests a complex magnetic field structure.

astro-ph.HE

The Wide Field Monitor (WFM) of the China-Europe eXTP (enhanced X-ray Timing and Polarimetry) mission

The eXTP mission is a major project of the Chinese Academy of Sciences (CAS), with a large involvement of Europe. Its scientific payload includes four instruments: SFA, PFA, LAD and WFM. They offer an unprecedented simultaneous wide-band Xray timing and polarimetry sensitivity. A large European consortium is contributing to the eXTP study, both for the science and the instrumentation. Europe is expected to provide two of the four instruments: LAD and WFM; the LAD is led by Italy and the WFM by Spain. The WFM for eXTP is based on the design originally proposed for the LOFT ESA M3 mission, that underwent a Phase A feasibility study. It will be a wide field of view X-ray monitor instrument working in the 2-50 keV energy range, achieved with large-area Silicon Drift Detectors (SDDs), similar to the ones used for the LAD but with better spatial resolution. The WFM will consist of 3 pairs of coded mask cameras with a total combined field of view (FoV) of 90x180 degrees at zero response and a source localisation accuracy of ~1 arc min. The main goal of the WFM is to provide triggers for the target of opportunity observations of the SFA, PFA and LAD, in order to perform the core science programme, dedicated to the study of matter under extreme conditions of density, gravity and magnetism. In addition, the unprecedented combination of large field of view and imaging capability, down to 2 keV, of the WFM will allow eXTP to make important discoveries of the variable and transient X-ray sky, and provide X-ray coverage of a broad range of astrophysical objects covered under 'observatory science', such as gamma-ray bursts, fast radio bursts, gravitational wave electromagnetic counterparts. In this paper we provide an overview of the WFM instrument, explaining its design, configuration, and anticipated performance.

astro-ph.IM

Insight-HXMT on-orbit thermal control status and thermal deformation impact analysis

Purpose: The Hard X-ray Modulation Telescope is China's first X-ray astronomy satellite launched on June 15th, 2017, dubbed Insight-HXMT. Active and passive thermal control measures are employed to keep devices at suitable temperatures. In this paper, we analyzed the on-orbit thermal monitoring data of the first 5 years and investigated the effect of thermal deformation on the point spread function (PSF) of the telescopes. Methods: We examined the data of the on-orbit temperatures measured using 157 thermistors placed on the collimators, detectors and their support structures and compared the results with the thermal control requirements. The thermal deformation was evaluated by the relative orientation of the two star sensors installed on the main support structure. its effect was estimated with evolution of the PSF obtained with calibration scanning observations of the Crab nebula. Conclusion: The on-orbit temperatures met the thermal control requirements thus far, and the effect of thermal deformation on the PSF was negligible after the on-orbit pointing calibration.

astro-ph.IM

In-orbit Performance of ME onboard Insight-HXMT in the first 5 years

Introduction: The Medium Energy X-ray telescope (ME) is a collimated X-ray telescope onboard the Insight hard X-ray modulation telescope (Insight-HXMT) satellite. It has 1728 Si-PIN pixels readout using 54 low noise application-specific integrated circuits (ASICs). ME covers the energy range of 5-30 keV and has a total detection area of 952 cm2. The typical energy resolution of ME at the beginning of the mission is 3 keV at 17.8 keV (Full Width at Half Maximum, FWHM) and the time resolution is 255 us. In this study, we present the in-orbit performance of ME in its first 5 years of operation. Methods: The performance of ME was monitored using onboard radioactive sources and astronomical X-ray objects. ME carries six 241Am radioactive sources for onboard calibration, which can continuously illuminate the calibration pixels. The long-term performance evolution of ME can be quantified using the properties of the accumulated spectra of the calibration pixels. In addition, observations of the Crab Nebula and the pulsar were used to check the long-term evolution of the detection efficiency as a function of energy. Conclusion: After 5 years of operation, 742 cm2 of the Si-PIN pixels were still working normally. The peak positions of 241Am emission lines gradually shifted to the high energy region, implying a slow increase in ME gain of 1.43%. A comparison of the ME spectra of the Crab Nebula and the pulsar shows that the E-C relations and the redistribution matrix file are still acceptable for most data analysis works, and there is no detectable variation in the detection efficiency.

astro-ph.IM

In-orbit performance of LE onboard Insight-HXMT in the first 5 years

Purpose: The Low-Energy X-ray telescope (LE) is a main instrument of the Insight-HXMT mission and consists of 96 Swept Charge Devices (SCD) covering the 1-10 keV energy band. The energy gain and resolution are continuously calibrated by analysing Cassiopeia A (Cas A) and blank sky data, while the effective areas are also calibrated with the observations of the Crab Nebula. In this paper, we present the evolution of the in-orbit performances of LE in the first 5 years since launch. Methods: The Insight-HXMT Data Analysis Software package (HXMTDAS) is utilized to extract the spectra of Cas A, blank sky, and Crab Nebula using different Good Time Interval (GTI) selections. We fit a model with a power-law continuum and several Gaussian lines to different ranges of Cas A and blank sky spectra to get peak energies of their lines through xspec. After updating the energy gain calibration in CALibration DataBase (CALDB), we rerun the Cas A data to obtain the energy resolution. An empirical function is used to modify the simulated effective areas so that the background-subtracted spectrum of the Crab Nebula can best match the standard model of the Crab Nebula. Results: The energy gain, resolution, and effective areas are calibrated every month. The corresponding calibration results are duly updated in CALDB, which can be downloaded and used for the analysis of Insight-HXMT data. Simultaneous observations with NuSTAR and NICER can also be used to verify our derived results. Conclusion: LE is a well calibrated X-ray telescope working in 1-10 keV band. The uncertainty of LE gain is less than 20 eV in 2-9 keV band and the uncertainty of LE resolution is less than 15eV. The systematic errors of LE, compared to the model of the Crab Nebula, are lower than 1.5% in 1-10 keV.

astro-ph.IM

The 100-m X-ray Test Facility at IHEP

The 100-m X-ray Test Facility of the Institute of High Energy Physics (IHEP) was initially proposed in 2012 for the test and calibration of the X-ray detectors of the Hard X-ray Modulation Telescope (HXMT) with the capability to support future X-ray missions. The large instrument chamber connected with a long vacuum tube can accommodate the X-ray mirror, focal plane detector and other instruments. The X-ray sources are installed at the other end of the vacuum tube with a distance of 105 m, which can provide an almost parallel X-ray beam covering 0.2$\sim$60 keV energy band. The X-ray mirror modules of the Einstein Probe (EP) and the enhanced X-ray Timing and Polarimetry mission (eXTP) and payload of the Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) have been tested and calibrated with this facility. It has been also used to characterize the focal plane camera and aluminum filter used on the Einstein Probe. In this paper, we will introduce the overall configuration and capability of the facility, and give a brief introduction of some calibration results performed with this facility.

astro-ph.IM

An Insight-HXMT view of the mHz quasi-regular modulation phenomenon in the black hole X-ray binary 4U 1630-47

Here we report the spectral-timing results of the black hole X-ray binary 4U 1630-47 during its 2021 outburst using observations from the Hard X-ray Modulation Telescope. Type-C quasi-periodic oscillations (QPOs) in 1.6--4.2 Hz and quasi-regular modulation (QRM) near 60 mHz are detected during the outburst. The mHz QRM has a fractional rms of 10%--16% in the 8--35 keV energy band with a Q factor (frequency/width) of 2--4. Benefiting from the broad energy band of hxmt, we study the energy dependence of the 60 mHz QRM in 1--100 keV for the first time. We find that the fractional rms of the mHz QRM increases with photon energy, while the time lags of the mHz QRM are soft and decrease with photon energy. Fast recurrence of the mHz QRM, in a timescale of less than one hour, has been observed during the outburst. During this period, the corresponding energy spectra moderately change when the source transitions from the QRM state to the non-QRM state. The QRM phenomena also shows a dependence with the accretion rate. We suggest that the QRM could be caused by an unknown accretion instability aroused from the corona.

astro-ph.HE

Quasi-periodic oscillations of the X-ray burst from the magnetar SGR J1935+2154 and associated with the fast radio burst FRB 200428

The origin(s) and mechanism(s) of fast radio bursts (FRBs), which are short radio pulses from cosmological distances, have remained a major puzzle since their discovery. We report a strong Quasi-Periodic Oscillation(QPO) of 40 Hz in the X-ray burst from the magnetar SGR J1935+2154 and associated with FRB 200428, significantly detected with the Hard X-ray Modulation Telescope (Insight-HXMT) and also hinted by the Konus-Wind data. QPOs from magnetar bursts have only been rarely detected; our 3.4 sigma (p-value is 2.9e-4) detection of the QPO reported here reveals the strongest QPO signal observed from magnetars (except in some very rare giant flares), making this X-ray burst unique among magnetar bursts. The two X-ray spikes coinciding with the two FRB pulses are also among the peaks of the QPO. Our results suggest that at least some FRBs are related to strong oscillation processes of neutron stars. We also show that we may overestimate the significance of the QPO signal and underestimate the errors of QPO parameters if QPO exists only in a fraction of the time series of a X-ray burst which we use to calculate the Leahy-normalized periodogram.

astro-ph.HE

Performance of a focal plane detector for soft X-ray imaging spectroscopy based on back-illuminated sCMOS

Spectroscopy focusing array (SFA) and Polarimetry focusing array (PFA) are the two major payloads of enhanced X-ray Timing and Polarimetry mission (eXTP). Nested Wolter-\RNum{1} X-ray mirror module is implemented in SFA and PFA to achive high effective area. When evaluating the properties of the mirror module, the alignment of the optical axis of the X-ray mirror module and a quasi-parallel X-ray beam is a prerequisite to ensure the accuracy of the results. Hence, to assist the alignment of the X-ray mirror module, an X-ray focal plane detector is designed based on the back-illuminated scientific Complementary Metal-Oxide-Semiconductor Transistor (sCMOS) sensor GSENSE6060BSI, one of the largest detection areas, is produced by \textit{Gpixel Inc}. Then the characteristics of readout noise, dark current, and split-pixel event properties of the detector are studied with the self-developed multi-target fluorescence X-ray source in a 100 m long X-ray test facility. The energy calibration is carried out with the single-pixel event and the energy non-linearity of the detector is also obtained. Eventually, the simulation of the eXTP mirror module based on the optical model is conducted and the alignment test of the Wolter-\RNum{1} X-ray mirror module designed for \textit{EP/FXT} (Einstein Probe/Follow-up X-ray Telescope) with "Burkert test" method is shown.

physics.ins-det

In-orbit timing calibration of the Insight-Hard X-ray Modulation Telescope

We describe the timing system and the timing calibration results of the three payloads on-board the Insight-Hard X-ray Modulation Telescope (Insight-HXMT). These three payloads are the High Energy X-ray telescope (HE, 20-250 keV), the Medium Energy X-ray telescope (ME, 5-30 keV) and the low Energy X-ray telescope (LE, 1-10 keV). We present a method to correct the temperature-dependent period response and the long-term variation of the on-board crystal oscillator, especially for ME that does not carry a temperature-compensated crystal oscillator. The time of arrivals (ToAs) of the Crab pulsar are measured to evaluate the accuracy of the timing system. As the ephemeris of the Crab pulsar given by Jodrell Bank observatory has systematic errors around 40 {\mu}s (Rots et al. 2014), we use the quasi-simultaneous observations of the X-ray Timing Instrument (XTI) on-board the Neutron star Interior Composition Explorer (NICER) to produce the Crab ephemerides and to verify the timing system of Insight-HXMT. The energy-dependent ToAs' offsets relative to the NICER measurements including physical and instrumental origins are about 24.7{\mu}s, 10.1{\mu}s and 864.7{\mu}s, and the systematic errors of the timing system are determined as 12.1{\mu}s, 8.6{\mu}s, and 15.8{\mu}s, for HE, ME and LE respectively.

astro-ph.HE

Design and test of a portable Gamma-Ray Burst simulator for GECAM

The main scientific goal of the Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) is to monitor various types of Gamma-Ray Bursts (GRB) originated from merger of binary compact stars, which could also produce gravitational wave, and collapse of massive stars. In order to study the response of GECAM Gamma-Ray Detectors (GRDs) to high-energy bursts and test the in-flight trigger and localization software of GECAM before the launch, a portable GRB simulator device is designed and implemented based on grid controlled X-ray tube (GCXT) and direct digital synthesis (DDS) technologies. The design of this GRB simulator which modulates X-ray flux powered by high voltage up to 20 kV is demonstrated, and the time jitter (FWHM) of the device is about 0.9 $\mu$s. Before the launch in December, 2020, both two GECAM satellites were irradiated by different types of GRBs (including short and long bursts in duration) generated by this GRB simulator. The light curves detected with GECAM/GRDs are consistent with the programmed input functions within statistical uncertainties, indicating the good performance of both the GRDs and the GRB simulator.

physics.ins-det

Insight-HXMT observations of jet-like corona in a black hole X-ray binary MAXI J1820+070

A black hole X-ray binary produces hard X-ray radiation from its corona and disk when the accreting matter heats up. During an outburst, the disk and corona co-evolves with each other. However, such an evolution is still unclear in both its geometry and dynamics. Here we report the unusual decrease of the reflection fraction in MAXI J1820+070, which is the ratio of the coronal intensity illuminating the disk to the coronal intensity reaching the observer, as the corona is observed to contrast during the decay phase. We postulate a jet-like corona model, in which the corona can be understood as a standing shock where the material flowing through. In this dynamical scenario, the decrease of the reflection fraction is a signature of the corona's bulk velocity. Our findings suggest that as the corona is observed to get closer to the black hole, the coronal material might be outflowing faster.

astro-ph.HE

Learning Discriminative Representations for Fine-Grained Diabetic Retinopathy Grading

Diabetic retinopathy (DR) is one of the leading causes of blindness. However, no specific symptoms of early DR lead to a delayed diagnosis, which results in disease progression in patients. To determine the disease severity levels, ophthalmologists need to focus on the discriminative parts of the fundus images. In recent years, deep learning has achieved great success in medical image analysis. However, most works directly employ algorithms based on convolutional neural networks (CNNs), which ignore the fact that the difference among classes is subtle and gradual. Hence, we consider automatic image grading of DR as a fine-grained classification task, and construct a bilinear model to identify the pathologically discriminative areas. In order to leverage the ordinal information among classes, we use an ordinal regression method to obtain the soft labels. In addition, other than only using a categorical loss to train our network, we also introduce the metric loss to learn a more discriminative feature space. Experimental results demonstrate the superior performance of the proposed method on two public IDRiD and DeepDR datasets.

cs.CV

In-flight calibration of the Insight-Hard X-ray Modulation Telescope

We present the calibration of the Insight-Hard X-ray Modulation Telescope (Insight-HXMT) X-ray satellite, which can be used to perform timing and spectral studies of bright X-ray sources. Insight-HXMT carries three main payloads onboard: the High Energy X-ray telescope (HE), the Medium Energy X-ray telescope (ME) and the Low Energy X-ray telescope (LE). In orbit, the radioactive sources, activated lines, the fluorescence lines and celestial sources are used to calibrate the energy scale and energy resolution of the payloads. The Crab nebular is adopted as the primary effective area calibrator and empirical functions are constructed to modify the simulated effective areas of the three payloads respectively. The systematic errors of HE, compared to the model of the Crab nebular, are less than 2% in 28--120 keV and 2%--10% above 120 keV. The systematic errors of ME are less than 1.5% in 10--35 keV. The systematic errors of LE are less than 1% in 1--7 keV except the Si K--edge (1.839 keV, up to 1.5%) and less than 2% in 7--10 keV.

astro-ph.IM

Design and Calibration of the High Energy Particle Monitor onboard the Insight-HXMT

Three high energy particle monitors (HPMs) employed onboard the Hard X-ray Modulation Telescope Insight-HXMT) can detect the charged particles from South Atlantic Anomaly (SAA) and hence provide the alert trigger for switch-on/off of the main detectors. Here a typical design of HPM with high stability and reliability is adopted by taking a plastic scintillator coupled with a small photomultiplier tube (PMT). The window threshold of HPM is designed as 1 MeV and 20 MeV for the incident electron and proton, respectively. Before the launch of Insight-HXMT, we performed in details the ground calibration of HPM. The measured energy response and its dependence on temperature are taken as essential input of Geant4 simulation for estimating the HPM count rate given with an incident particle energy spectrum. This serves as a guidance for choosing a reasonable working range of the PMT high voltage once the real SAA count rate is measured by HPM in orbit. So far the three HPMs have been working in orbit for more than two years. Apart from providing reliable alert trigger, the HPMs data are used as well to map the SAA region.

physics.ins-det

The Medium Energy (ME) X-ray telescope onboard the Insight-HXMT astronomy satellite

The Medium Energy X-ray telescope (ME) is one of the three main telescopes on board the Insight Hard X-ray Modulation Telescope (Insight-HXMT) astronomy satellite. ME contains 1728 pixels of Si-PIN detectors sensitive in 5-30 keV with a total geometrical area of 952 cm2. Application Specific Integrated Circuit (ASIC) chips, VA32TA6, is used to achieve low power consumption and low readout noise. The collimators define three kinds of field of views (FOVs) for the telescope, 1{\deg}{\times}4{\deg}, 4{\deg}{\times}4{\deg}, and blocked ones. Combination of such FOVs can be used to estimate the in-orbit X-ray and particle background components. The energy resolution of ME is ~3 keV at 17.8 keV (FWHM) and the time resolution is 255 {\mu}s. In this paper, we introduce the design and performance of ME.

astro-ph.IM