Reduction of quantum noise using the quantum locking with an optical spring for gravitational wave detectors

In our previous research, simulation showed that a quantum locking scheme with homodyne detection in sub-cavities is effective in surpassing the quantum noise limit for Deci-hertz Interferometer Gravitational Wave Observatory (DECIGO) in a limited frequency range. This time we have simulated an optical spring effect in the sub-cavities of the quantum locking scheme. We found that the optimized total quantum noise is reduced in a broader frequency band, compared to the case without the optical spring effect significantly improving the sensitivity of DECIGO to the primordial gravitational waves.

gr-qc↗

Prospects for improving the sensitivity of the cryogenic gravitational wave detector KAGRA

Upgrades to improve the sensitivity of gravitational wave detectors enable more frequent detections and more precise source parameter estimation. Unlike other advanced interferometric detectors such as Advanced LIGO and Advanced Virgo, KAGRA requires different approach for the upgrade since it is the only detector which employs cryogenic cooling of the test masses. In this paper, we describe possible KAGRA upgrades with technologies focusing on different detector bands, and compare the impacts on the detection of compact binary coalescences. We show that either fivefold improvement in the $100 M_{\odot}$--$100 M_{\odot}$ binary black hole range, a factor of 1.3 improvement in the binary neutron star range, or a factor of 1.7 improvement in the sky localization of binary neutron stars is well feasible with upgrades that do not require changes in the existing cryogenic or vacuum infrastructure. We also show that twofold broadband sensitivity improvement is possible by applying multiple upgrades to the detector.

gr-qc↗

Atto-Nm Torque Sensing with a Macroscopic Optomechanical Torsion Pendulum

Precise measurements of the displacement of, and force acting on, a mechanical oscillator can be performed by coupling the oscillator to an optical cavity. Brownian thermal forces represent a fundamental limit to measurement sensitivity which impedes the ability to use precise force measurements as a tool of fundamental enquiry, particularly in the context of macroscopic quantum measurements and table-top gravitational experiments. A torsion pendulum with a low mechanical resonant frequency can be limited by very small thermal forces - from its suspensions - at frequencies above resonance. Here, we report torque sensing of a 10-mg torsion pendulum formed by a bar mirror, using two optical cavities on either edge. The rotational mode was measured by subtracting the two signals from the cavities, while intracavity radiation pressure forces were used to trap the torsional mode with a 1 kHz optical spring. The resulting torque sensitivity of 20 aNm/$\sqrt{\rm Hz}$ is a record for a milligram scale torsion pendulum. Such a massive optomechanical device featuring high sensitivity can shed light on macroscopic quantum mechanics and gravitational physics.

quant-ph↗

Design and experimental demonstration of a laser modulation system for future gravitational-wave detectors

Detuning the signal-recycling cavity length from a cavity resonance significantly improves the quantum noise beyond the standard quantum limit, while there is no km-scale gravitational-wave detector successfully implemented the technique. The detuning technique is known to introduce great excess noise, and such noise can be reduced by a laser modulation system with two Mach-Zehnder interferometers in series. This modulation system, termed Mach-Zehnder Modulator (MZM), also makes the control of the gravitational-wave detector more robust by introducing the third modulation field which is non-resonant in any part of the main interferometer. On the other hand, mirror displacements of the Mach-Zehnder interferometers arise a new kind of noise source coupled to the gravitational-wave signal port. In this paper, the displacement noise requirement of the MZM is derived, and also results of our proof-of-principle experiment is reported.

astro-ph.IM↗

Mirror actuation design for the interferometer control of the KAGRA gravitational wave telescope

KAGRA is a 3-km cryogenic interferometric gravitational wave telescope located at an underground site in Japan. In order to achieve its target sensitivity, the relative positions of the mirrors of the interferometer must be finely adjusted with attached actuators. We have developed a model to simulate the length control loops of the KAGRA interferometer with realistic suspension responses and various noises for mirror actuation. Using our model, we have designed the actuation parameters to have sufficient force range to acquire lock as well as to control all the length degrees of freedom without introducing excess noise.

physics.ins-det↗

Prospects for improving the sensitivity of KAGRA gravitational wave detector

KAGRA is a new gravitational wave detector which aims to begin joint observation with Advanced LIGO and Advanced Virgo from late 2019. Here, we present KAGRA's possible upgrade plans to improve the sensitivity in the decade ahead. Unlike other state-of-the-art detectors, KAGRA requires different investigations for the upgrade since it is the only detector which employs cryogenic cooling of the test mass mirrors. In this paper, investigations on the upgrade plans which can be realized by changing the input laser power, increasing the mirror mass, and injecting frequency dependent squeezed vacuum are presented. We show how each upgrade affects to the detector frequency bands and also discuss impacts on gravitational-wave science. We then propose an effective progression of upgrades based on technical feasibility and scientific scenarios.

gr-qc↗

Particle swarm optimization of the sensitivity of a cryogenic gravitational wave detector

Cryogenic cooling of the test masses of interferometric gravitational wave detectors is a promising way to reduce thermal noise. However, cryogenic cooling limits the incident power to the test masses, which limits the freedom of shaping the quantum noise. Cryogenic cooling also requires short and thick suspension fibers to extract heat, which could result in the worsening of thermal noise. Therefore, careful tuning of multiple parameters is necessary in designing the sensitivity of cryogenic gravitational wave detectors. Here, we propose the use of particle swarm optimization to optimize the parameters of these detectors. We apply it for designing the sensitivity of the KAGRA detector, and show that binary neutron star inspiral range can be improved by 10%, just by retuning seven parameters of existing components. We also show that the sky localization of GW170817-like binaries can be further improved by a factor of 1.6 averaged across the sky. Our results show that particle swarm optimization is useful for designing future gravitational wave detectors with higher dimensionality in the parameter space.

gr-qc↗

A Direct Approach for the Fluctuation-Dissipation Theorem under Non-Equilibrium Steady-State Conditions

The test mass suspensions of cryogenic gravitational-wave detectors such as the KAGRA project are tasked with extracting the heat deposited on the optics. Thus these suspensions have a non-uniform temperature, requiring the calculation of thermal noise in non-equilibrium conditions. While it is not possible to describe the whole suspension system with one temperature, the local temperature anywhere in the system is still well defined. We therefore generalize the application of the fluctuation-dissipation theorem to mechanical systems, pioneered by Saulson and Levin, to non-equilibrium conditions in which a temperature can only be defined locally. The result is intuitive in the sense that the temperature-averaging relevant for the thermal noise in the observed degree of freedom is given by averaging the temperature field, weighted by the dissipation density associated with that particular degree of freedom. After proving this theorem we apply the result to examples of increasing complexity: a simple spring, the bending of a pendulum suspension fiber, as well as a model of the KAGRA cryogenic suspension. We conclude by outlining the application to non-equilibrium thermo-elastic noise.

gr-qc↗

Standard quantum limit of angular motion of a suspended mirror and homodyne detection of ponderomotively squeezed vacuum field

Compared to the quantum noise in the measurement of the translational motion of a suspended mirror using laser light, the quantum noise in the measurement of the angular motion of a suspended mirror has not been investigated intensively despite its potential importance. In this article, an expression for the quantum noise in the angular motion measurement is explicitly derived. The expression indicates that one quadrature of the vacuum field of the first-order Hermite-Gaussian mode of light causes quantum sensing noise and the other causes quantum backaction noise, or in other words the first-order vacuum field is ponderomotively squeezed. It is also shown that the Gouy phase shift the light acquires between the mirror and the position of detection of the light corresponds to the homodyne angle. Therefore, the quantum backaction noise can be cancelled and the standard quantum limit can be surpassed by choosing the appropriate position of detection analogously to the cancellation of quantum radiation pressure noise by choosing an appropriate homodyne angle.

quant-ph↗