SearcharxivSearch

arXiv subjects

Zhaoli Gao

Publications and source records attributed to Zhaoli Gao.

7 recordsLinked to original sources

Phase amplification microscopy with femtometer-level accuracy

We demonstrate a major breakthrough in laser interferometry and microscopy achieving femtometer-level measurement accuracy and beyond, termed Phase Amplification microscopy (Φ-Amp). By exploiting the native silicide substrate as a phase cavity, our phase-gain theory predicts that weak sub-atomic phase signals can be magnified over 1000-fold, thus bypassing the shot-noise limit. We experimentally achieved a 158.2-fold phase gain for graphene in ambient air, corresponding ~ 730 femtometer accuracy. To fully unleash the potential of Φ-Amp for atomic fabrication and quantum measurement, we quantified interlayer spacing differences between AB-stacked and 30-degree-twisted bilayer graphene to be ~ 0.77 Angstroms and further detected atomic impurities and defects on large atomic structures. As the first wide-field metrology tool, we envision Φ-Amp may accelerate the scaling up of atomic quantum devices.

physics.optics

Electrically Tunable Magnetoconductance of Close-Packed CVD Bilayer Graphene Layer Stacking Walls

Quantum valley Hall (QVH) domain wall states are a new class of one-dimensional (1D) one-way conductors that are topologically protected in the absence of valley mixing. Development beyond a single QVH channel raises important new questions as to how QVH channels in close spatial proximity interact with each other, and how that interaction may be controlled. Scalable epitaxial bilayer graphene synthesis produces layer stacking wall (LSW) bundles, where QVH channels are bound, providing an excellent platform to study QVH channel interactions. Here we show that distinct strain sources lead to the formation of both well-separated LSWs and close packed LSW bundles. Comparative studies of electronic transport in these two regimes reveal that close-packed LSW bundles support electrically tunable magnetoconductance. The coexistence of different strain sources offers a potential pathway to realize scalable quantum transport platform based on LSWs where electrically tunability enables programmable functionality.

cond-mat.mes-hall

Emergent Moiré fringes in direct-grown quasicrystal

Quasicrystals represent a category of rarely structured solids that challenge traditional periodicity in crystal materials. Recent advancements in the synthesis of two-dimensional (2D) van der Waals materials have paved the way for exploring the unique physical properties of these systems. Here, we report on the synthesis of 2D quasicrystals featuring 30° alternating twist angles between multiple graphene layers, using chemical vapor deposition (CVD). Strikingly, we observed periodic Moiré patterns in the quasicrystal, a finding that has not been previously reported in traditional alloy-based quasicrystals. The Moiré periodicity, varying with the parity of the constituent layers, aligns with the theoretical predictions that suggest a stress cancellation mechanism in force. The emergence of Moiré fringes is attributed to the spontaneous mismatched lattice constant in the oriented graphene layers, proving the existence of atomic relaxation. This phenomenon, which has been largely understudied in graphene systems with large twist angles, has now been validated through our use of scanning transmission electron microscopy (STEM). Our CVD-grown Moiré quasicrystal provides an ideal platform for exploring the unusual physical properties that arise from Moiré periodicity within quasicrystals.

cond-mat.mtrl-sci

Transmission-matrix Quantitative Phase Profilometry for Accurate and Fast Thickness Mapping of 2D Materials

The physical properties of two-dimensional (2D) materials may drastically vary with their thickness profiles. Current thickness profiling methods for 2D material (e.g., atomic force microscopy and ellipsometry) are limited in measurement throughput and accuracy. Here we present a novel high-speed and high-precision thickness profiling method, termed Transmission-Matrix Quantitative Phase Profilometry (TM-QPP). In TM-QPP, picometer-level optical pathlength sensitivity is enabled by extending the photon shot-noise limit of a high sensitivity common-path interferometric microscopy technique, while accurate thickness determination is realized by developing a transmission-matrix model that accounts for multiple refractions and reflections of light at sample interfaces. Using TM-QPP, the exact thickness profiles of monolayer and few-layered 2D materials (e.g., MoS2, MoSe2 and WSe2) are mapped over a wide field of view within seconds in a contact-free manner. Notably, TM-QPP is also capable of spatially resolving the number of layers of few-layered 2D materials.

physics.optics

Controlled Growth of Large-Area Bilayer Tungsten Diselenides with Lateral P-N Junctions

Bilayer two-dimensional (2D) van der Waals (vdW) materials are attracting increasing attention due to their predicted high quality electronic and optical properties. Here we demonstrate dense, selective growth of WSe2 bilayer flakes by chemical vapor deposition with the use of a 1:10 molar mixture of sodium cholate and sodium chloride as the growth promoter to control the local diffusion of W-containing species. A large fraction of the bilayer WSe2 flakes showed a 0 and 60o twist between the two layers, while moire 15 and 30o-twist angles were also observed. Well-defined monolayer-bilayer junctions were formed in the as-grown bilayer WSe2 flakes, and these interfaces exhibited p-n diode rectification and an ambipolar transport characteristic. This work provides an efficient method for the layer-controlled growth of 2D materials, in particular, 2D transition metal dichalcogenides and promotes their applications in next-generation electronic and optoelectronic devices.

cond-mat.mtrl-sci

Scalable Graphene Aptasensors for Drug Quantification

Simpler and more rapid approaches for therapeutic drug-level monitoring are highly desirable to enable use at the point-of-care. We have developed an all-electronic approach for detection of the HIV drug tenofovir based on scalable fabrication of arrays of graphene field-effect transistors (GFETs) functionalized with a commercially available DNA aptamer. The shift in the Dirac voltage of the GFETs varied systematically with the concentration of tenofovir in deionized water, with a detection limit less than 1 ng/mL. Tests against a set of negative controls confirmed the specificity of the sensor response. This approach offers the potential for further development into a rapid and convenient point-of-care tool with clinically relevant performance.

physics.app-ph

pH sensing properties of flexible, bias-free graphene microelectrodes in complex fluids: from phosphate buffer solution to human serum

Advances in techniques for monitoring pH in complex fluids could have significant impact on analytical and biomedical applications ranging from water quality assessment to in vivo diagnostics. We developed flexible graphene microelectrodes (GEs) for rapid (< 5 seconds), very low power (femtowatt) detection of the pH of complex biofluids. The method is based on real-time measurement of Faradaic charge transfer between the GE and a solution at zero electrical bias. For an idealized sample of phosphate buffer solution (PBS), the Faradaic current varied monotonically and systematically with the pH with resolution of ~0.2 pH unit. The current-pH dependence was well described by a hybrid analytical-computational model where the electric double layer derives from an intrinsic, pH-independent (positive) charge associated with the graphene-water interface and ionizable (negative) charged groups described by the Langmuir-Freundlich adsorption isotherm. We also tested the GEs in more complex bio-solutions. In the case of a ferritin solution, the relative Faradaic current, defined as the difference between the measured current response and a baseline response due to PBS, showed a strong signal associated with the disassembly of the ferritin and the release of ferric ions at pH ~ 2.0. For samples of human serum, the Faradaic current showed a reproducible rapid (<20s) response to pH. By combining the Faradaic current and real time current variation, the methodology is potentially suitable for use to detect tumor-induced changes in extracellular pH.

physics.bio-ph