SearcharxivSearch

arXiv subjects

Zisis Papandreou

Publications and source records attributed to Zisis Papandreou.

4 recordsLinked to original sources

Beam test of a Pb/SciFi prototype for the Barrel Imaging Calorimeter at the Electron-Ion Collider

A Lead-Scintillating Fiber (Pb/SciFi) prototype for the Barrel Imaging Calorimeter (BIC) at the Electron--Ion Collider (EIC) was tested with electron beams at the CERN PS T10 beam line in August 2024. The prototype consisted of unit modules with a sampling structure of lead sheets and scintillating fibers, corresponding to a total depth of approximately $10.9\,X_{0}$. Beam tests were performed with electron momenta between 0.5 and 3~GeV/$c$ to evaluate the energy and timing performance of the prototype. This study characterizes the performance of a Pb/SciFi prototype and provides input for future beam tests, calibration and readout optimization, and the development of larger-scale prototypes.

physics.ins-det

Evaluation of the Response to Electrons and Pions in the Scintillating Fiber and Lead Calorimeter for the Future Electron-Ion Collider

The performance of the Baby Barrel Electromagnetic Calorimeter (Baby BCAL) - a small-scale lead-scintillating-fiber (Pb/ScFi) prototype of the GlueX Barrel Electromagnetic Calorimeter (BCAL) - was tested in a dedicated beam campaign at the Fermilab Test Beam Facility (FTBF). This study provides a benchmark for the Pb/ScFi component of the future Barrel Imaging Calorimeter (BIC) in the ePIC detector at the Electron-Ion Collider (EIC). The detector response to electrons and pions was studied at beam energies between 4 and 10 GeV, extending previous GlueX tests [NIM A 596 (2008) 327-337 and arXiv:1801.03088] to a higher energy regime. The calibrated detector exhibits good linearity within uncertainties, and its electron energy resolution meets EIC requirements. The data further constrain the constant term in the energy resolution to below 1.9%, improving upon previous constraints at lower energies. Simulations reproduce key features of the electron and pion data within the limitations of the collected dataset and the FTBF test environment. Electron-pion separation in the test beam setup was analyzed using multiple methods, incorporating varying degrees of beam-related effects. The inclusion of longitudinal shower profile information enhanced the separation performance, underscoring its relevance for the full-scale BIC in ePIC. These results provide essential benchmarks for the Pb/ScFi section of the future BIC, validating detector simulations and guiding optimization strategies for electron-pion discrimination.

physics.ins-det

Strange Hadron Spectroscopy with Secondary KL Beam in Hall D

We propose to create a secondary beam of neutral kaons in Hall D at Jefferson Lab to be used with the GlueX experimental setup for strange hadron spectroscopy. The superior CEBAF electron beam will enable a flux on the order of $1\times 10^4~K_L/sec$, which exceeds the flux of that previously attained at SLAC by three orders of magnitude. The use of a deuteron target will provide first measurements ever with neutral kaons on neutrons. The experiment will measure both differential cross sections and self-analyzed polarizations of the produced $\Lambda$, $\Sigma$, $\Xi$, and $\Omega$ hyperons using the GlueX detector at the Jefferson Lab Hall D. The measurements will span CM $\cos\theta$ from $-0.95$ to 0.95 in the range W = 1490 MeV to 2500 MeV. The new data will significantly constrain the partial wave analyses and reduce model-dependent uncertainties in the extraction of the properties and pole positions of the strange hyperon resonances, and establish the orbitally excited multiplets in the spectra of the $\Xi$ and $\Omega$ hyperons. Comparison with the corresponding multiplets in the spectra of the charm and bottom hyperons will provide insight into he accuracy of QCD-based calculations over a large range of masses. The proposed facility will have a defining impact in the strange meson sector through measurements of the final state $K\pi$ system up to 2 GeV invariant mass. This will allow the determination of pole positions and widths of all relevant $K^\ast(K\pi)$ $S$-,$P$-,$D$-,$F$-, and $G$-wave resonances, settle the question of the existence or nonexistence of scalar meson $\kappa/K_0^\ast(700)$ and improve the constrains on their pole parameters. Subsequently improving our knowledge of the low-lying scalar nonet in general.

nucl-ex

Construction and Performance of the Barrel Electromagnetic Calorimeter for the GlueX Experiment

The barrel calorimeter is part of the new spectrometer installed in Hall D at Jefferson Lab for the GlueX experiment. The calorimeter was installed in 2013, commissioned in 2014 and has been operating routinely since early 2015. The detector configuration, associated Monte Carlo simulations, calibration and operational performance are described herein. The calorimeter records the time and energy deposited by charged and neutral particles created by a multi-GeV photon beam. It is constructed as a lead and scintillating-fiber calorimeter and read out with 3840 large-area silicon photomultiplier arrays. Particles impinge on the detector over a wide range of angles, from normal incidence at 90 degrees down to 11.5 degrees, which defines a geometry that is fairly unique among calorimeters. The response of the calorimeter has been measured during a running experiment and performs as expected for electromagnetic showers below 2.5 GeV. We characterize the performance of the BCAL using the energy resolution integrated over typical angular distributions for $\pi^0$ and $\eta$ production of $\sigma_E/E$=5.2\%/$\sqrt{E(\rm{GeV})} \oplus$ 3.6\% and a timing resolution of $\sigma$\,=\,150\,ps at 1\,GeV.

physics.ins-det