SearcharxivSearch

arXiv subjects

Zu-Ke Feng

Publications and source records attributed to Zu-Ke Feng.

4 recordsLinked to original sources

Design and preliminary performance study of the broad-band spectrometer detector for POLAR-2

POLAR-2, the successor of the POLAR experiment aboard China's Tiangong-2 space lab, is set to be deployed on the China Space Station. The POLAR-2 mission aims to conducting high-precision polarization measurements of high-energy transients with a primary focus on Gamma-Ray Bursts (GRBs), following POLAR's pioneering accurate polarization measurements of GRB prompt emission. One of the key advancements in POLAR-2 is the inclusion of a dedicated Broad-band Spectrometer Detector (BSD) instrument, designed to provide precise measurements of GRB location and spectral parameters, which are critical inputs for accurate polarization analysis of POLAR-2's dedicated High-energy Polarimetry Detector (HPD), which is made of plastic scintillator bars array. BSD employs a coded-aperture mask imaging technique and pixelated GAGG scintillation crystals, offering a wide half-coded field of view of ~132° x 125° and an operational energy range of 10-1000 keV. Simulation results indicate that the instrument can achieve a localization accuracy of approximately 1.5° for faint GRBs similar to GRB 170817A, satisfying the core requirements of GRB polarimetry with HPD. BSD also has moderate capability for GRB polarimetry, particularly at several hundred keV energy. This paper outlines the preliminary design of BSD and presents an overall evaluation of its expected scientific performance, based on extensive Monte Carlo simulations and preliminary ground-based calibration tests.

astro-ph.IM

In-orbit background and sky survey simulation study of POLAR-2/LPD

The Low-Energy X-ray Polarization Detector (LPD) is one of the payloads in the POLAR-2 experiment, designed as an external payload for the China Space Station (CSS) deployment in early 2024. LPD is specifically designed to observe the polarization of Gamma-Ray Bursts (GRBs) prompt emission in the energy range of 2-10 keV, with a wide field of view (FoV) of 90 degrees in preliminary design. This observation is achieved using an array of X-ray photoelectric polarimeters based on gas pixel detectors. Due to the wide FoV configuration, the in-orbit background count rate in the soft X-ray range is high, while GRBs themselves also exhibit a high flux in this energy band. In order to assess the contribution of various background components to the total count rate, we conducted detailed simulations using the GEANT4 C++ package. Our simulations encompassed the main interactions within the instrument materials and provided insights into various background components within the wide FoV scheme. The simulation results reveal that among the background components, the primary contributors are the cosmic X-ray background (CXB) and bright X-ray sources. The total background count rate of LPD, after applying the charged particle background rejection algorithm, is approximately 0.55 counts/cm^2/s on average, and it varies with the detector's orbit and pointing direction. Furthermore, we performed comprehensive simulations and comparative analyses of the CXB and X-ray bright sources under different FoVs and detector pointings. These analyses provide valuable insights into the background characteristic for soft X-ray polarimeter with wide FoV.

astro-ph.IM

Wide-Field X-ray Polarimetry for High Energy Astronomical Transients: First results of the pathfinder CXPD Cubesat Mission

The Low Energy Polarization Detector (LPD) is a key component of the next-generation large-scale Gamma-Ray Burst polarimeter, POLAR-2. It is designed for polarization observations of transient sources in the soft X-ray energy range with a wide field of view (FOV). To validate the key technologies required for wide-FOV X-ray polarization measurements, the Cosmic X-ray Polarization Detector (CXPD) CubeSat was developed as a prototype for the LPD. The CXPD is equipped with two Gas Microchannel Plate Pixel Detectors (GMPDs) that measure X-ray polarization via the photoelectric effect, where ejected photoelectrons produce ionization tracks in the gas which are imaged to reconstruct their emission directions. Laboratory calibrations of the modulation factor and energy spectra were successfully performed using linear polarized X-ray sources at 2.98 keV, 4.51 keV, 6.40 keV, and 8.05 keV. Since its launch in June 2023, the CXPD has successfully completed critical in-orbit technology verification. It has also performed polarization observations of two bright X-ray sources Sco X-1 and the transient Swift J1727.8-1613 yielding constraints on their polarization degrees and angles. Notably, this was the first time that an anti-coincidence detector had been implemented in an X-ray polarimeter, enabling in-orbit verification of the charged-particle background rejection algorithm. These results demonstrate the feasibility of wide-field soft X-ray polarization measurements and provide essential guidance for the development of the LPD for the POLAR-2 mission, thereby advancing the frontier of X-ray polarization astronomy.

astro-ph.IM

Polarization degree of magnetic field structure changes caused by random magnetic field in Gamma-ray Burst

In a Poynting-flux-dominated (PFD) jet that exhibits an ordered magnetic field, a transition towards turbulence and magnetic disorder follows after magnetic reconnection and energy dissipation during the prompt emission phase. In this process, the configuration of the magnetic field evolves with time, rendering it impossible to entirely categorize the magnetic field as ordered. Therefore, we assumed a crude model that incorporates a random magnetic field and an ordered magnetic field, and takes into account the proportionality of the random magnetic field strength to the ordered magnetic field, in order to compute the polarization degree (PD) curve for an individual pulse. It has been discovered that the random magnetic field has a significant impact on the PD results of the low-energy X-ray. In an ordered magnetic field, the X-ray segment maintains a significant PD compared to those in the hundreds of keV and MeV ranges even after electron injection ceases, this making PD easier to detect by polarimetry. However, when the random magnetic field is introduced, the low-energy and high-energy PDs exhibit a similar trend, with the X-ray PD being lower than that of the high-energy segment. Of course, this is related to the rate of disorder in the magnetic field. Additionally, there is two rotation of the polarization angles (PAs) that were not present previously, and the rotation of the PA in the high-energy segment occurs slightly earlier. These results are unrelated to the structure of the ordered magnetic field.

astro-ph.HE