Searcharxiv⌕ Search

SEARCH · Searcharxiv

Results for “physics.ins-det”

Search indexed arXiv papers on artificial intelligence, large language models, computer vision and robotics. Read source abstracts and follow links to arXiv.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12Linked to original sources

Correction of beam-beam effects in luminosity measurement at ILC

Three methods for handling beam-beam effects in luminosity measurement at ILC are tested and evaluated in this work. The first method represents an optimization of the LEP-type asymmetric selection cuts that reduce the counting biases. The second method uses the experimentally reconstructed shape of the $\sqrt{s'}$ spectrum to determine the Beamstrahlung component of the bias. The last, recently proposed, collision-frame method relies on the reconstruction of the collision-frame velocity to define the selection function in the collision frame both in experiment and in theory. Thus the luminosity expression is insensitive to the difference between the CM frame of the collision and the lab frame. The collision-frame method is independent of the knowledge of the beam parameters, and it allows an accurate reconstruction of the luminosity spectrum above 80 % of the nominal CM energy. However, it gives no precise infromation about luminosity below 80 % of the nominal CM energy. The compatibility of diverse selection cuts for background reduction with the collision-frame method is addressed.

physics.acc-ph↗

Mu2e Conceptual Design Report

Mu2e at Fermilab will search for charged lepton flavor violation via the coherent conversion process mu- N --> e- N with a sensitivity approximately four orders of magnitude better than the current world's best limits for this process. The experiment's sensitivity offers discovery potential over a wide array of new physics models and probes mass scales well beyond the reach of the LHC. We describe herein the conceptual design of the proposed Mu2e experiment. This document was created in partial fulfillment of the requirements necessary to obtain DOE CD-1 approval, which was granted July 11, 2012.

physics.ins-det↗

Lifetime measurements of 214Po and 212Po with the CTF liquid scintillator detector at LNGS

We have studied the alpha decays of 214Po into 210Pb and of 212Po into 208Pb tagged by the coincidence with the preceding beta decays from 214Bi and 212Bi, respectively. The employed 222Rn, 232Th, and 220Rn sources were sealed inside quartz vials and inserted in the Counting Test Facility at the underground Gran Sasso National Laboratory in Italy. We find that the mean lifetime of 214Po is (236.00 +- 0.42(stat) +- 0.15(syst)) μs and that of 212Po is (425.1 +- 0.9(stat) +- 1.2(syst)) ns. Our results, obtained from data with signal-to-background ratio larger than 1000, reduce the overall uncertainties and are compatible with previous measurements.

nucl-ex↗

The use of a high intensity neutrino beam from the ESS proton linac for measurement of neutrino CP violation and mass hierarchy

It is proposed to complement the ESS proton linac with equipment that would enable the production, concurrently with the production of the planned ESS beam used for neutron production, of a 5 MW beam of 10$^{23}$ 2.5 GeV protons per year in microsecond short pulses to produce a neutrino Super Beam, and to install a megaton underground water Cherenkov detector in a mine to detect $ν_e$ appearance in the produced $ν_μ$ beam. Results are presented of preliminary calculations of the sensitivity to neutrino CP violation and the mass hierarchy as a function of the neutrino baseline. The results indicate that, with 8 years of data taking with an antineutrino beam and 2 years with a neutrino beam and a baseline distance of around 400 km, CP violation could be discovered at 5 $σ$ (3 $σ$) confidence level in 48% (73%) of the total CP violation angular range. With the same baseline, the neutrino mass hierarchy could be determined at 3 $σ$ level over most of the total CP violation angular range. There are several underground mines with a depth of more than 1000 m, which could be used for the creation of the underground site for the neutrino detector and which are situated within or near the optimal baseline range.

hep-ex↗

Calorimetry for Lepton Collider Experiments - CALICE results and activities

The CALICE collaboration conducts calorimeter R&D for highly granular calorimeters, mainly for their application in detectors for a future lepton collider at the TeV scale. The activities ranges from generic R&D with small devices up to extensive beam tests with prototypes comprising up to several 100000 calorimeter cells. CALICE has validated the performance of particle flow algorithms with test beam data and delivers the proof of principle that highly granular calorimeters can be built, operated and understood. The successes achieved in the past years allows the step from prototypes to calorimeter systems for particle physics detectors to be addressed.

physics.ins-det↗

Investigation of gamma ray detection performance of thin LFS scintillator with MAPD readout

Prototype of gamma ray detector based on Micro Pixel Avalanche Photodiodes (MAPD) with high pixel density 15000 pixel/$mm^2$, optically coupled to Lutetium Fine Silicate (LFS) scintillator has been developed. The detection performance investigated in the range of energy 59.6 - 662 keV at room temperature. The results of measurements are presented in this work.

physics.ins-det↗

A method for statistical comparison of histograms

We propose an approach for testing the hypothesis that two realizations of the random variables in the form of histograms are taken from the same statistical population (i.e. that two histograms are drawn from the same distribution). The approach is based on the notion "significance of deviation". Our approach allows also to estimate the statistical difference between two histograms.

physics.data-an↗

Geant4 Applications for Modeling Molecular Transport in Complex Vacuum Geometries

We discuss a novel use of the Geant4 simulation toolkit to model molecular transport in a vacuum environment, in the molecular flow regime. The Geant4 toolkit was originally developed by the high energy physics community to simulate the interactions of elementary particles within complex detector systems. Here its capabilities are utilized to model molecular vacuum transport in geometries where other techniques are impractical. The techniques are verified with an application representing a simple vacuum geometry that has been studied previously both analytically and by basic Monte Carlo simulation. We discuss the use of an application with a very complicated geometry, that of the Large Synoptic Survey Telescope camera cryostat, to determine probabilities of transport of contaminant molecules to optical surfaces where control of contamination is crucial.

physics.comp-ph↗

Study of gas contaminants and interaction with materials in RPC closed loop system

Resistive Plate Counters (RPC) detectors at the Large Hadron Collider (LHC) experiments use gas recirculation systems to cope with large gas mixture volumes and costs. In this paper a long-term systematic study about gas purifiers, gas contaminants and detector performance is discussed. The study aims at measuring the lifetime of purifiers with new and used cartridge material along with contaminants release in the gas system. During the data-taking the response of several RPC double-gap detectors was monitored in order to characterize the correlation between dark currents, filter status and gas contaminants.

physics.ins-det↗

More Reliable Measurements of the Slip Length with the Atomic Force Microscope

Further improvements are made to the non-linear data analysis algorithm for the atomic force microscope [P. Attard, arXiv:1212.3019v2 (2012)]. The algorithm is required when there is curvature in the compliance region due to photo-diode non-linearity. Results are obtained for the hydrodynamic drainage force, for three surfaces: hydrophilic silica (symmetric, Si-Si), hydrophobic dichlorodimethylsilane (symmetric, DCDMS-DCDMS), and hydrophobic octadecyltrichlorosilane (asymmetric, Si-OTS). The drainage force was measured in the viscous liquid di-n-octylphthalate. The slip-lengths are found to be 3nm for Si, 2nm for DCDMS, and 2nm for OTS, with an uncertainty on the order of a nanometer. These slip lengths are a factor of 4--15 times smaller than those obtained from previous analysis of the same raw data [L. Zhu et al., Langmuir, 27, 6712 (2011). Ibid, 28, 7768 (2012)].

cond-mat.soft↗

Testing the Pauli Exclusion Principle for Electrons

One of the fundamental rules of nature and a pillar in the foundation of quantum theory and thus of modern physics is represented by the Pauli Exclusion Principle. We know that this principle is extremely well fulfilled due to many observations. Numerous experiments were performed to search for tiny violation of this rule in various systems. The experiment VIP at the Gran Sasso underground laboratory is searching for possible small violations of the Pauli Exclusion Principle for electrons leading to forbidden X-ray transitions in copper atoms. VIP is aiming at a test of the Pauli Exclusion Principle for electrons with high accuracy, down to the level of 10$^{-29}$ - 10$^{-30}$, thus improving the previous limit by 3-4 orders of magnitude. The experimental method, results obtained so far and new developments within VIP2 (follow-up experiment at Gran Sasso, in preparation) to further increase the precision by 2 orders of magnitude will be presented.

nucl-ex↗

Dispersive Casimir Pressure Effect from Surface Plasmon Quanta by Quasi 1D Metal Wires in Ferrite Disks and The Josephson Frequencies and Currents

Ferrites are distinct material for electromagnetic applications due to its unique spin precession. In this paper, Casimir pressure effect by deploying magnetically tunable surface plasmon quanta in stratified structure of using ferrite and metal wires is presented. Previously, oscillating surface plasmon quanta were successfully included to modify first reflection and first transmission characteristics. The oscillating surface plasmon quanta in the modified reflection in such a system, not only does resolve in a typical matter in metamaterial, but also provide new applications such as creating Casimir pressure effects through the metamaterial composite shown in this paper. The Casimir pressure flips from attractive state to repulsive state is referred to cause mechanism of radiation from surface plasmon quanta. Both Casimir force analysis and the measured data of radiations indicate us the system develops quantized states by electric flux induced by ferromagnetic resonance. Quantum analysis is used to understand the discrete radiations spectra for our experimental measurement. The discrete radiations are reproduced by using time dependent Schrödinger representation. As a result, we find the Josephson frequency and Josephson current representations at room temperature and we used them for extrapolating voltage induced in excited ferrites. Josephson frequency at X-band is able to differentiate micron volt differences and it allows us to report the data for voltage induced by ferromagnetic resonance in ferrite at room temperature. It is understood that the radiation intensity depends on density of final states and excitation probability when we come to think the energy matter. It seems possible to create as high as 20mW microwave power inside waveguide at X-band.

physics.ins-det↗

Sterile Neutrino Search Using China Advanced Research Reactor

We study the feasibility of a sterile neutrino search at the China Advanced Research Reactor by measuring $\bar ν_e$ survival probability with a baseline of less than 15 m. Both hydrogen and deuteron have been considered as potential targets. The sensitivity to sterile-to-regular neutrino mixing is investigated under the "3(active)+1(sterile)" framework. We find that the mixing parameter $\sin^2(2θ_{14})$ can be severely constrained by such measurement if the mass square difference $Δm_{14}^2$ is of the order of $\sim$1 eV$^2$.

physics.ins-det↗

New constraint on the existence of the mu+-> e+ gamma decay

The analysis of a combined data set, totaling 3.6 \times 10^14 stopped muons on target, in the search for the lepton flavour violating decay mu^+ -> e^+ gamma is presented. The data collected by the MEG experiment at the Paul Scherrer Institut show no excess of events compared to background expectations and yield a new upper limit on the branching ratio of this decay of 5.7 \times 10^-13 (90% confidence level). This represents a four times more stringent limit than the previous world best limit set by MEG.

hep-ex↗

Ultracold neutron accumulation in a superfluid-helium converter with magnetic multipole reflector

We analyze accumulation of ultracold neutrons (UCN) in a superfluid-helium converter vessel surrounded by a magnetic multipole reflector. We solved the spin-dependent rate equation, employing formulas valid for adiabatic spin transport of trapped UCN in mechanical equilibrium. Results for saturation UCN densities are obtained in dependence of order and strength of the multipolar field. The addition of magnetic storage to neutron optical potentials can increase the density and energy of the low field seeking UCN produced and serves to mitigate the effects of wall losses on the source performance. It also can provide a highly polarized sample of UCN without need to polarize the neutron beam incident on the converter. This work was performed in preparation of the UCN source project SuperSUN at the ILL.

physics.ins-det↗

Nanoscale resolution immersion scanning thermal microscopy

Nanoscale thermal properties are becoming of extreme importance for modern electronic circuits that dissipate increasing power on the length scale of few tens of nanometers, and for chemical and physical properties sensors and biosensors using nanoscale sized features. While Scanning Thermal Microscopy (SThM) is known for its ability to probe thermal properties and heat generation with nanoscale resolution, until today it was perceived impossible to use it in the liquid environment due to dominating direct heat exchange between microfabricated thermal probe and surrounding liquid that would deteriorate spatial resolution. Nonetheless, our theoretical analysis of SThM in liquids showed that for certain design of SThM probe with resistive heater located near the probe tip, their thermal signal is only moderately affected, by less than half on immersion in a dodecane environment. More significantly, its spatial resolution, surprisingly, would remain practically unaffected, and the thermal contact between the tip apex and the studied sample would be beneficially improved. Our experimental trials of such immersion SThM, or iSThM, were fully successful and here we report for the first time nanoscale SThM measurements of thermal conductivity of Ultra Large Scale Integration polymerceramic metal interconnects with the spatial thermal resolution down to 50 nm. Further studies of heat transport in nanoscale graphite flakes in iSThM suggested, in particular, that highly anisotropic thermal conductivity in graphene layers may play significant role in the nanoscale thermal transport in liquid environment. New iSThM opens a wide range of applications from noncontact measurements of thermal transport in semiconductor devices to exploring graphene energy storage, catalytic reactions and heat generation in biological systems.

physics.ins-det↗

The ATLAS Inner Detector operation, data quality and tracking performance

The ATLAS Inner Detector is responsible for particle tracking in ATLAS experiment at CERN Large Hadron Collider (LHC) and comprises silicon and gas based detectors. The combination of both silicon and gas based detectors provides high precision impact parameter and momentum measurement of charged particles, with high efficiency and small fake rate. The ID has been used to exploit fully the physics potential of the LHC since the first proton-proton collisions at 7 TeV were delivered in 2009. The performance of track and vertex reconstruction is presented, as well as the operation aspects of the Inner Detector and the data quality during the many months of data taking.

physics.ins-det↗

High-precision Absolute Coordinate Measurement using Frequency Scanned Interferometry

In this paper, we report high-precision absolute position measurement performed with frequency scanned interferometry (FSI). We reported previously on measurement of absolute distance with FSI [1]. Absolute position is determined by several related absolute distances measured simultaneously. The achieved precision of 2-dimensional measurements is better than 1 micron, and in 3-dimensional measurements, the precision on X and Y is confirmed to be below 1 micron, while the confirmed precision on Z is about 2 microns, where the confirmation is limited by the lower precision of the moving stage in Z direction.

physics.ins-det↗