arXiv · 1403.2909
Impedance Matched Absorptive Thermal Blocking Filters
Abstract
We have designed, fabricated and characterized absorptive thermal blocking filters for cryogenic microwave applications. The transmission line filter's input characteristic impedance is designed to match $50\,Ω$ and its response has been validated from 0-to-50\,GHz. The observed return loss in the 0-to-20\,GHz design band is greater than $20\,$dB and shows graceful degradation with frequency. Design considerations and equations are provided that enable this approach to be scaled and modified for use in other applications.
Explore related subjects
Keep this discovery
E. J. Wollack, D. T. Chuss, K. Rostem, K. U-Yen. 2014-03-12. Impedance Matched Absorptive Thermal Blocking Filters. https://doi.org/10.1063/1.4869038
Cite the original work for its findings. Save a collection to share your selection of sources.