arXiv · 1404.5811
Construction and measurements of a vacuum-swing-adsorption radon-mitigation system
Abstract
Long-lived alpha and beta emitters in the $^{222}$Rn decay chain on (and near) detector surfaces may be the limiting background in many experiments attempting to detect dark matter or neutrinoless double-beta decay, and in screening detectors. In order to reduce backgrounds from radon-daughter plate-out onto the wires of the BetaCage during its assembly, an ultra-low-radon cleanroom is being commissioned at Syracuse University using a vacuum-swing-adsorption radon-mitigation system. The radon filter shows ~20$\times$ reduction at its output, from 7.47$\pm$0.56 to 0.37$\pm$0.12 Bq/m$^3$, and the cleanroom radon activity meets project requirements, with a lowest achieved value consistent with that of the filter, and levels consistently < 2 Bq/m$^3$.
Explore related subjects
Keep this discovery
R. W. Schnee, R. Bunker, G. Ghulam, D. Jardin, M. Kos, A. S. Tenney. 2014-04-23. Construction and measurements of a vacuum-swing-adsorption radon-mitigation system. https://doi.org/10.1063/1.4818089
Cite the original work for its findings. Save a collection to share your selection of sources.