arXiv · 1407.4013
A modified Michelson interferometer type Raman laser system for atom interferometers
Abstract
We have developed a modified Michelson interferometer type Raman laser system to manipulate cold 87 Rb atoms to interfere. A frequency modulated continuous wave technique was introduced to determine the optical path difference, thus compensating it to zero to minimize the effects of common mode noise. The linewidth (full width at half maximum) of the beat signal at 6.834 GHz was measured to 1Hz limited by the resolution bandwidth of the spectral analyzer. The measured rms phase variance of the phase noise at 166 MHz was 0.015 rad2, mainly restricted by our poor performance radio frequency microwave source. With modest improvements, we plan to apply this laser system to form an atom interferometer for acceleration and rotation measurements.
Explore related subjects
Keep this discovery
Ningfang Song, Xiangxiang Lu, Wei Li, Yang Li, Yingying Wang, Jixun Liu, Xiaobin Xu, Xiong Pan. 2014-07-15. A modified Michelson interferometer type Raman laser system for atom interferometers. https://arxiv.org/abs/1407.4013
Cite the original work for its findings. Save a collection to share your selection of sources.