arXiv · 1504.01884
A new anti-neutrino detection technique based on positronium tagging with plastic scintillators
Abstract
The main signature for anti-neutrino detection in reactor and geo-neutrino experiments based on scintillators is provided by the space-time coincidence of positron and neutron produced in the Inverse Beta Decay reaction. Such a signature strongly suppresses backgrounds and allows for measurements performed underground with a relatively high signal-to-background ratio. In an aboveground environment, however, the twofold coincidence technique is not sufficient to efficiently reject the high background rate induced by cosmogenic events. Enhancing the positron-neutron twofold coincidence efficiency has the potential to pave the way future aboveground detectors for reactor monitoring. We propose a new detection scheme based on a threefold coincidence, between the positron ionization, the ortho-positronium (o-Ps) decay, and the neutron capture, in a sandwich detector with alternated layers of plastic scintillator and aerogel powder. We present the results of a set of dedicated measurements on the achievable light yield and on the o-Ps formation and lifetime. The efficiencies for signal detection and background rejection of a preliminary detector design are also discussed.
Explore related subjects
Keep this discovery
G. Consolati, D. Franco, C. Jollet, A. Meregaglia, A. Minotti, S. Perasso, A. Tonazzo. 2015-04-08. A new anti-neutrino detection technique based on positronium tagging with plastic scintillators. https://doi.org/10.1016/j.nima.2015.06.021
Cite the original work for its findings. Save a collection to share your selection of sources.