SearcharxivSearch

arXiv · 1508.02460

The SST Multi-G-Sample/s Switched Capacitor Array Waveform Recorder with Flexible Trigger and Picosecond-Level Timing Accuracy

Abstract

The design and performance of a multi-G-sample/s fully-synchronous analog transient waveform recorder I.C. ("SST") with fast and flexible trigger capabilities is presented. Containing 4 channels of 256 samples per channel and fabricated in a 0.25 {\mu}m CMOS process, it has a 1.9V input range on a 2.5V supply, achieves 12 bits of dynamic range, and uses ~160 mW while operating at 2 G-samples/s and full trigger speeds. With a standard 50 Ohm input source, the SST's analog input bandwidth is ~1.3 GHz within about +/-0.5 dB and reaches a -3 dB bandwidth of 1.5 GHz. The SST's internal sample clocks are generated synchronously via a shift register driven by an external LVDS oscillator, interleaved to double its speed (e.g., a 1 GHz clock yields 2 G-samples/s). It can operate over 6 orders of magnitude in sample rates (2 kHz to 2 GHz). Only three active control lines are necessary for operation: Reset, Start/Stop and Read-Clock. Each of the four channels integrates dual-threshold discrimination of signals with ~1 mV RMS resolution at >600 MHz bandwidth. Comparator results are directly available for simple threshold monitoring and rate control. The High and Low discrimination can also be AND'd over an adjustable window of time in order to exclusively trigger on bipolar impulsive signals. Trigger outputs can be CMOS or low-voltage differential signals, e.g. 1.2V CMOS or positive-ECL (0-0.8V) for low noise. After calibration, the imprecision of timing differences between channels falls in a range of 1.12-2.37 ps sigma at 2 G-samples/s.

Explore related subjects

Keep this discovery

BibTeXRIS

Stuart A. Kleinfelder, Edwin Chiem, Tarun Prakash. 2015-08-11. The SST Multi-G-Sample/s Switched Capacitor Array Waveform Recorder with Flexible Trigger and Picosecond-Level Timing Accuracy. https://arxiv.org/abs/1508.02460

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det