arXiv · 1608.03849
Proposal of Readout Electronics for CSNS-WNS BaF2 Detector
Abstract
BaF2 (Barium fluoride) detector is one of the experiment facilities at the under construction CSNS-WNS (White Neutron Source at China Spallation Neutron Source). It is designed for precisely measuring (n,gamma) cross section with total 92 crystal elements and completely 4 pi steradian coverage. In this proposal for readout electronics, waveform digitizing technique with 1GSps sampling rate and 12-bit resolution is adopted to precisely capture the detector signal. To solve the problem of massive data readout and processing, the readout electronics system is designed into a distributed architecture with 4 PXIe crates. The digitized detector's signal is concentrated to PXIe crate controller through PCIe bus on backplane and transmitted to data acquisition system over Gigabit Ethernet in parallel. Besides, clock and trigger can be fanned out synchronously to each electronic channel over a high-precision distributing network. Test results showed that the prototype of the readout electronics system achieved good performance and cooperated well.
Explore related subjects
Keep this discovery
Deliang Zhang, Ping Cao, Qi Wang, Bing He, Yaxi Zhang, Xincheng Qi, Tao Yu, Qi An. 2016-08-12. Proposal of Readout Electronics for CSNS-WNS BaF2 Detector. https://arxiv.org/abs/1608.03849
Cite the original work for its findings. Save a collection to share your selection of sources.