Non-Invertibility of spectral x-ray photon counting data with pileup

Abstract

-In the Alvarez-Macovski method [R.E. Alvarez and A. Macovski, Phys. Med. Biol., 1976, 733-744], the attenuation coefficient is approximated as a linear combination of functions of energy multiplied by coefficients that depend on the material composition at points within the object. The method then computes the line integrals of the basis set coefficient from measurements with different x-ray spectra. This paper shows that the transformation from photon counting detector data with pileup to the line integrals can become ill-conditioned under some circumstances leading to highly increased noise. Methods: An idealized model that includes pileup and quantum noise is used. The noise variance of the line integral estimates is computed using the Cram{\`e}r-Rao lower bound (CRLB). The CRLB is computed as a function of object thickness for photon counting detector data with three and four bin pulse height analysis (PHA) and low and high pileup. Results: With four bin PHA data the transformation is well conditioned with either high or low pileup. With three bin PHA and high pileup, the transformation becomes ill-conditioned for specific values of object attenuation. At these values the CRLB variance increases by approximately 10 5 compared with the four bin PHA or low pileup results. The condition number of the forward transformation matrix also shows a spike at those attenuation values. Conclusion: Designers of systems using counting detectors should study the stability of the line integral estimator output with their data.

Explore related subjects

Keep this discovery

BibTeXRIS

Robert Alvarez. 2017-02-16. Non-Invertibility of spectral x-ray photon counting data with pileup. https://arxiv.org/abs/1702.04993

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det