SearcharxivSearch

arXiv · 1711.02117

MiniCLEAN Dark Matter Experiment

Abstract

The MiniCLEAN dark matter experiment will exploit a single-phase liquid-argon detector instrumented with 92 photomultiplier tubes placed in the cryogen temperature with 4-$\pi$ coverage of a 500 kg (150 kg) target (fiducial) mass. The detector design strategy emphasizes scalability to target masses of order 10 tons or more. The detector is designed also for a liquid neon target that allows for an independent verification of signal and background and a test of the expected dependence of the WIMP-nucleus interaction rate. For MiniCLEAN, PMT stability and calibration are essential. The \textit{In-situ} optical calibration will be able monitor the PMT stability and maintain the calibration. In MiniCLEAN, we use a Light-Emitting Diode(LED)- based light injection system to provide single photons for calibration, the calibration can be performed in near real-time, providing a continuous monitor at the condition of the detector. The intrinsic $^{39}$Ar beta emitter provides another way to calibrate the detector thanks to well defined properties and uniformly distributed inside the detector volume. The energy scale can be determined by fitting the energy spectrum of experimental $^{39}$Ar data. Moreover, the preliminary results from cold gas run shows the best measurement on triplet lifetime ($\sim$ 3.5 $\mu$ s). The results confirms the high purity of argon is attained by MiniCLEAN's purification system. The long triplet lifetime in gaseous argon can be exploit to obtain better performance of pulse shape discrimination (PSD) for future dark matter detector, also the low density of gaseous argon reduced the multi-scattering neutron backgrounds. On the other hand, by injecting $^{39}$Ar spike, the electronic recoil events due to $^{39}$Ar beta decay can be used to test the limit of PSD in liquid argon. The results will be informative for future multi-tonne LAr detector.

Explore related subjects

Keep this discovery

BibTeXRIS

JuiJen, Wang. 2017-11-06. MiniCLEAN Dark Matter Experiment. https://arxiv.org/abs/1711.02117

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det