SearcharxivSearch

arXiv · 1806.01490

Design of 32-channel TDC Based on Single FPGA for {\mu}SR Spectrometer at CSNS

Abstract

Muon Spin Rotation, Relaxation and Resonance ({\mu}SR) technology has an irreplaceable role in studying the microstructure and properties of materials, especially micro-magnetic properties. An experimental muon source is being built in China Spallation Neutron Source (CSNS) now. At the same time, a 128-channel {\mu}SR spectrometer as China's first {\mu}SR spectrometer is being developed. The time spectrum of {\mu}SR can be obtained by fitting the curve of positron count rate with time. This paper presents a 32-channel Time-to-Digital Converter (TDC) implemented in a Xilinx Virtex-6 Field Programmable Gate Array (FPGA) for measuring the positron's flight time of {\mu}SR Spectrometer. Signal of each channel is sampled by 16 equidistant shifted-phase 200 MHz sampling clocks, so the TDC bin size is 312.5ps. The measuring range is up to 327us. This TDC has the ability to store multiple hit signals in a short time with a deep hit-buffer up to 512. Time tag is added to each data to record the moment when the data was detected. Programmable time window and channel shielding give the flexibility to choose the time range and channels of interest. The delay of each channel can be calibrated. The data is transmitted to data acquisition system (DAQ) through Gigabit Ethernet. TDC and control logic are configured in real time by DAQ. The results of test show that the Full Width at Half Maximum (FWHM) precision of single channel is better than 273 ps with a low sensitivity to temperature and the linearity is pretty well.

Explore related subjects

Keep this discovery

BibTeXRIS

Fanshui Deng, Hao Liang, Bangjiao Ye, Jingyu Tang. 2018-06-05. Design of 32-channel TDC Based on Single FPGA for {\mu}SR Spectrometer at CSNS. https://arxiv.org/abs/1806.01490

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det