SearcharxivSearch

arXiv · 1806.07874

Optimizing momentum resolution with a new fitting method for silicon-strip detectors

Abstract

A new fitting method is explored for momentum reconstruction of tracks in a constant magnetic field for a silicon-strip tracker. Substantial increases of momentum resolution respect to standard fit is obtained. The key point is the use of a realistic probability distribution for each hit (heteroscedasticity). Two different methods are used for the fits, the first method introduces an effective variance for each hit, the second method implements the maximum likelihood search. The tracker model is similar to the PAMELA tracker. Each side, of the two sided of the PAMELA detectors, is simulated as momentum reconstruction device. One of the two is similar to silicon micro-strip detectors of large use in running experiments. Two different position reconstructions are used for the standard fits, the $η$-algorithm (the best one) and the two-strip center of gravity. The gain obtained in momentum resolution is measured as the virtual magnetic field and the virtual signal-to-noise ratio required by the two standard fits to reach an overlap with the best of two new methods. For the best side, the virtual magnetic field must be increased 1.5 times respect to the real field to reach the overlap and 1.8 for the other. For the high noise side, the increases must be 1.8 and 2.0. The signal-to-noise ratio has similar increases but only for the $η$-algorithm. The signal-to-noise ratio has no effect on the fits with the center of gravity. Very important results are obtained if the number N of detecting layers is increased, our methods provide a momentum resolution growing linearly with N, much higher than standard fits that grow as the $\sqrt{N}$.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Gregorio Landi, Giovanni E. Landi. 2018-06-14. Optimizing momentum resolution with a new fitting method for silicon-strip detectors. https://doi.org/10.3390/instruments2040022

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det