arXiv · 1810.05551
The Study of Ratio Algorithm for Radiographic Imaging with Cosmic-ray Muons
Abstract
The paper[1] presented a novel muon radiography technique which exploits the multiple Coulomb scattering of these particles for nondestructive inspection without the use of artificial radiation. In this paper, a new kind algorithm named Ratio Algorithm was proposed for imaging with the test object. The experimentally produced cosmic-ray muons radiographs was reconstructed. The more important, the reconstruction was made using data from only 793 muons.
Explore related subjects
Keep this discovery
Liu Cheng-Ming, Wen Qun-Gang, Zhang Zhi-Yong, Huang Guang-Shun. 2018-10-12. The Study of Ratio Algorithm for Radiographic Imaging with Cosmic-ray Muons. https://arxiv.org/abs/1810.05551
Cite the original work for its findings. Save a collection to share your selection of sources.