arXiv · 1810.10784
Charge Measurement of Cosmic Ray Nuclei with the Plastic Scintillator Detector of DAMPE
Abstract
One of the main purposes of the DArk Matter Particle Explorer (DAMPE) is to measure the cosmic ray nuclei up to several tens of TeV or beyond, whose origin and propagation remains a hot topic in astrophysics. The Plastic Scintillator Detector (PSD) on top of DAMPE is designed to measure the charges of cosmic ray nuclei from H to Fe and serves as a veto detector for discriminating gamma-rays from charged particles. We propose in this paper a charge reconstruction procedure to optimize the PSD performance in charge measurement. Essentials of our approach, including track finding, alignment of PSD, light attenuation correction, quenching and equalization correction are described detailedly in this paper after a brief description of the structure and operational principle of the PSD. Our results show that the PSD works very well and almost all the elements in cosmic rays from H to Fe are clearly identified in the charge spectrum.
Explore related subjects
Keep this discovery
Tiekuang Dong, Yapeng Zhang, Pengxiong Ma, Yongjie Zhang, Paolo Bernardini, Meng Ding, Dongya Guo, Shijun Lei, Xiang Li, Ivan De Mitri, Wenxi Peng, Rui Qiao, Margherita Di Santo, Zhiyu Sun, Antonio Surdo, Zhaomin Wang, Jian Wu, Zunlei Xu, Yuhong Yu, Qiang Yuan, Chuan Yue, Jingjing Zang, Yunlong Zhang. 2018-10-25. Charge Measurement of Cosmic Ray Nuclei with the Plastic Scintillator Detector of DAMPE. https://doi.org/10.1016/j.astropartphys.2018.10.001
Cite the original work for its findings. Save a collection to share your selection of sources.