SearcharxivSearch

arXiv · 1906.00646

A photomultiplier tube test stand and on-site measurements to characterise the performance of Photonis XP3062 photomultiplier tubes at increased background light conditions and lower gain

Abstract

Photomultiplier tubes (PMTs) are widely used in astroparticle physics experiments to detect light flashes (e.g. fluorescence or Cherenkov light) from extensive air showers (EASs) initiated by statistically rare very high energy cosmic particles when travelling through the atmosphere. Their high amplification factor (gain) allows the detection of very low photon fluxes down to single photons. At the same time this sensitivity causes the gain and signal-to-noise ratio to decrease with collected charge over the lifetime of the PMT (referred to as "ageing"). To avoid fast ageing, many experiments limit the PMT operation to reasonably low night sky background (NSB) conditions. However, in order to collect more event statistics at the highest energies, it is desirable to extend the measurement cycle into (part of) nights with higher NSB levels. In case the signal-to-noise ratio remains large enough in the subsequent reconstruction of the EAS events, lowering the PMT gain in such conditions can be an option to avoid faster ageing. In this paper, performance studies under high NSB with Photonis XP3062 PMTs, as used in the fluorescence detector of the Pierre Auger Observatory, are presented. The results suggest that lowering the PMT gain by a factor of 10 while increasing the NSB level by a similar factor does not significantly affect the PMT performance and ageing behaviour so that detection and offline reconstruction of EASs are still possible. Adjusting the PMT gain according to a changing NSB level throughout a night has been shown to be possible and it follows a predictable behaviour. This allows to extend the measurement cycles of experiments, based on PMTs of type Photonis XP3062 or comparable and exposed to the NSB, to enhance the sensitivity especially at the highest energies where events are very rare.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J. Zorn, K. Daumiller, R. Engel, H. -J. Mathes, M. Riegel, R. Smida, F. Werner. 2019-06-03. A photomultiplier tube test stand and on-site measurements to characterise the performance of Photonis XP3062 photomultiplier tubes at increased background light conditions and lower gain. https://doi.org/10.1016/j.nima.2019.05.065

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det