SearcharxivSearch

arXiv · 1910.04317

Ultra-low radioactivity Kapton and copper-Kapton laminates

Abstract

Polyimide-based materials, like Kapton, are widely used in flexible cables and circuitry due to their unique electrical and mechanical characteristics. This study is aimed at investigating the radiopurity of Kapton for use in ultralow background, rare-event physics applications by measuring the $^{238}$U, $^{232}$Th, and $^{nat}$K levels using inductively coupled plasma mass spectrometry. Commercial-off-the-shelf Kapton varieties, measured at approximately 950 and 120 pg/g $^{238}$U and $^{232}$Th (1.2$\times$10$^4$ and 490 $μ$Bq/kg), respectively, can be a significant background source for many current and next-generation ultralow background detectors. This study has found that the dominant contamination is due to the use of dicalcium phosphate (DCP), a nonessential slip additive added during manufacturing. Alternative Kapton materials were obtained that did not contain DCP and were determined to be significantly more radiopure than the commercially-available options with 12 and 19 pg/g $^{238}$U and $^{232}$Th (150 and 77 $μ$Bq/kg), respectively. The lowest radioactivity version produced (Kapton ELJ, which contains an adhesive) was found to contain single digit pg/g levels of $^{238}$U and $^{232}$Th, two-to-three orders of magnitude cleaner than commercial-off-the-shelf options. Moreover, copper-clad polyimide laminates employing Kapton ELJ as the insulator were obtained and shown to be very radiopure at 8.6 and 22 pg/g $^{238}$U and $^{232}$Th (110 and 89 $μ$Bq/kg), respectively.

Explore related subjects

Keep this discovery

BibTeXRIS

Isaac J. Arnquist, Chelsie Beck, Maria Laura di Vacri, Khadouja Harouaka, Richard Saldanha. 2019-10-10. Ultra-low radioactivity Kapton and copper-Kapton laminates. https://doi.org/10.1016/j.nima.2020.163573

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det