SearcharxivSearch

arXiv · 2005.06264

Investigation and improvements of the mechanical structure of Cylindrical GEMs for the BESIII experiment

Abstract

Gas Electron Multipliers (GEMs) can be produced in large foils and molded in different shapes. The possibility to create cylindrical layers has opened the opportunity to use such detector as internal tracker at collider experiments. One crucial item is to have low material budget in the active area, so the supporting structure of anode and cathode must be light. KLOE2 collaboration has built the first Cylindrical GEM detector with honeycomb material with carbon fiber skins produced at high temperature. BESIII is developing an innovative CGEM detector with charge and time readout. Among several innovative features, the mechanical structure was designed to be a sandwich of Rohacell and Kapton, a PMI foam. After the transportation of a first production of the detectors from the construction site in Italy to the Institute of High Energy Physics in Beijing, some malfunctions have been observed in some of them, compatible with GEMs deformation inside the detector. We have performed a detailed study by means of an industrial CT scan available in IHEP laboratory and autopsy to the damaged detectors. In this talk, we will review the construction process, the shipment, the findings of the investigation. A new supporting structure of carbon fiber and honeycomb, assembled at room temperature, has been designed and developed. The thickness of the carbon fiber is small enough to keep the material budget of a single detector layer below 0.5$\%$ of a radiation length, while the mechanical robustness results beyond the purpose of a detector for HEP. A first detector with such a mechanical structure has been built and shipped to IHEP, preliminary results from operation (e.g. current stability, discharges, temperature and humidity correlation) of the detectors will be also presented in this talk.

Explore related subjects

Keep this discovery

BibTeXRIS

Ilaria Balossino. 2020-05-13. Investigation and improvements of the mechanical structure of Cylindrical GEMs for the BESIII experiment. https://doi.org/10.1088/1748-0221/15/08/c08013

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det