ATLAS hardware-based Endcap Muon Trigger for future upgrades

Abstract

The LHC is expected to increase its center-of-mass energy from 13 TeV to 14 TeV for Run 3 scheduled from 2022 to 2024. After Run 3, upgrades for the High-Luminosity-LHC (HL-LHC) programme are planned and the operation will start in 2027, increasing the instantaneous luminosity to 5.0 -- 7.5 times its nominal luminosity. Continuous upgrades of the ATLAS trigger system are planned to cope with the high event rate and to keep the physics acceptance. During the long shutdown period before Run 3, new detectors will be installed to improve the trigger performance. New trigger logic, combining information from detectors located outside of the magnetic field and new detectors installed inside the magnetic field, are introduced from Run 3 to reduce the trigger rate. In order to handle data from the various detectors, a new trigger processor board has been developed and the design is presented. During the upgrade for HL-LHC, the trigger and readout systems of the first level hardware-based part are planned to be upgraded. Full-granularity information will be transferred to the trigger processor board which enables more off-line like track reconstruction in the hardware-based system. To handle the full-granularity information and perform the hardware-based track reconstruction, the trigger processor board will implement an FPGA with hundreds of pairs of transceivers and huge memory resources. Expected performance for the hardware-based endcap muon trigger in Run 3 and HL-LHC will also be presented.

Explore related subjects

Keep this discovery

BibTeXRIS

Yuya Mino. 2020-10-22. ATLAS hardware-based Endcap Muon Trigger for future upgrades. https://doi.org/10.1109/tns.2021.3084098

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det