SearcharxivSearch

arXiv · 2101.09164

Gas cooling of test masses for future gravitational-wave observatories

Abstract

Recent observations made with Advanced LIGO and Advanced Virgo have initiated the era of gravitational-wave astronomy. The number of events detected by these "2nd Generation" (2G) ground-based observatories is partially limited by noise arising from temperature-induced position fluctuations of the test mass mirror surfaces used for probing spacetime dynamics. The design of next-generation gravitational-wave observatories addresses this limitation by using cryogenically cooled test masses; current approaches for continuously removing heat (resulting from absorbed laser light) rely on heat extraction via black-body radiation or conduction through suspension fibres. As a complementing approach for extracting heat during observational runs, we investigate cooling via helium gas impinging on the test mass in free molecular flow. We establish a relation between cooling power and corresponding displacement noise, based on analytical models, which we compare to numerical simulations. Applying this theoretical framework with regard to the conceptual design of the Einstein Telescope (ET), we find a cooling power of 10 mW at 18 K for a gas pressure that exceeds the ET design strain noise goal by at most a factor of $\sim 3$ in the signal frequency band from 3 to 11 Hz. A cooling power of 100 mW at 18 K corresponds to a gas pressure that exceeds the ET design strain noise goal by at most a factor of $\sim 11$ in the band from 1 to 28 Hz.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Christoph Reinhardt, Alexander Franke, Jörn Schaffran, Roman Schnabel, Axel Lindner. 2021-01-18. Gas cooling of test masses for future gravitational-wave observatories. https://doi.org/10.1088/1361-6382%2Fac18bc

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det