SearcharxivSearch

arXiv · 2110.12668

Ultra-low jitter clock distribution for the trigger electronics of the New Small Wheel for the ATLAS experiment

Abstract

The Large Hadron Collider (LHC) at CERN plans to have a series of upgrades to increase its instantaneous luminosity to 7.5 the nominal luminosity. The increased luminosity drastically impacts the ATLAS trigger and readout data rates. The inner-most station of the ATLAS muon spectrometer, the so-called Small Wheels is being replaced with a New Small Wheel (NSW) system, consisting of Micromegas and small-strip Thin Gap Chambers (sTGC) detectors. The on-detector radiation levels required radiation tolerant electronics. The lower radiation levels on the rim of the NSW allowed utilizing commercial electronic chips, such as Field Programmable Gate Arrays (FPGAs), in the trigger chain of the sTGC detectors. Those FPGAs require an ultra-low jitter clock for the proper operation of their Gigabit transceivers (4.8 Gbps serial links). The initial design was based on a clock provided by a radiation tolerant ASIC designed at CERN, but due to its intrinsic jitter and consequent marginal error rate on the transmission lines, a different approach had to be chosen. An additional clock source based on commercial jitter cleaners, fan-out chips and optical transmitters driving dedicated fibers was built. The new scheme provides 64 low-jitter clocks (32 main and redundant) from the radiation-protected area (USA15) to the trigger electronics over 60 m of OM3 fiber.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T. Alexopoulos, T. Geralis, P. Gkountoumis, L. Levinson, I. Mesolongitis, O. Zormpa. 2021-10-25. Ultra-low jitter clock distribution for the trigger electronics of the New Small Wheel for the ATLAS experiment. https://doi.org/10.1088/1748-0221%2F17%2F05%2Fc05012

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det